56 61 0.3 Foot: L L CE1 10 30 38 43 47 0.5 W W W CE2 F 5 24 31 36 39 0.7 11 17 19 21 0.3 ML2B 7 11 13 13 G 0.5 ML1C 1 10 50 100 200 300400 Max. speed u (mm/s) (Initial cushioning speed) 4 7 9 9 0.7 500 REA Front trunnion: U Rear trunnion: T 32 42 48 52 0.3 Clevis: C, D C 22 30 35 37 0.5 REC Graph w Applicable max. stroke against lateral load* D 17 24 27 29 0.7 RHC W W W 500 82 103 116 127
M12 x 1.75 27 14 34 35 34 100 125 15 100 250 16 112 170 M27 x 2 38 6.5 140 140 112 35.5 80 35 27 19 M14 x 2 27 16 34 35 34 100 160 17 110 279 18 140 197 M33 x 2 42 9 174 174 140 45 100 38 36 22 M16 x 2 28 18 38 40 43 108 (mm) Bore size (mm) Y ZZ P R S T V W X 40 8 246 1/4 37 114 11 7.5 8 27 50 10 262 3/8 43 116 11 10 9 30 63 10 280 3/8 47 120 11 12 10 37 80 13 312 1/2 57 132 11 16 13 40 100
11 6.6 9 10 50 15 12 50 65 12 33 30 32 45 45 12 9 11 12 63 15 16 52 67 14 37 35 40 50 50 15 9 11 12 80 18 16 66 86 18 47 40 50 60 63 15 11 12.5 14 100 18 20 11 76 96 20 55 13.5 50 60 70 71 15 19 Mounting style (CR): Head side clevis with ball joint A B C D EN ER F E L M N P H Bore size (mm) 0.2 max 0.2 H7 0.1 max H11 H13 H13 0.5 0.5 32 22 10 14 15 30 5 32.5 10.5 6.6 45 10.5 5.5 40 38 12
11 6.6 9 10 50 15 12 50 65 12 33 30 32 45 45 12 9 11 12 63 15 16 52 67 14 37 35 40 50 50 15 9 11 12 80 18 16 66 86 18 47 40 50 60 63 15 11 12.5 14 100 18 20 11 76 96 20 55 13.5 50 60 70 71 15 19 Mounting style (CR): Head side clevis with ball joint A B C D EN ER F E L M N P H Bore size (mm) 0.2 max 0.2 H7 0.1 max H11 H13 H13 0.5 0.5 32 22 10 14 15 30 5 32.5 10.5 6.6 45 10.5 5.5 40 38 12
7.5 9.5 9.5 10.5 D-A5, A6 9 9 10 11 11 11 D-A59W 13 13 13 14 14 15 D-A3, A44 9 9 10 11 11 11 10 D-Y59, Y69 D-Y7P, Y7V D-Y7W, Y7WV 7 5.5 5.5 7 7.5 6.5 5.5 D-Y7BAL 6 3.5 3.5 3.5 4 4.5 5 D-F5, J5 D-F5W, J59W D-F5BAL, F5NTL D-F59F 3.5 4 4 4.5 4.5 4.5 5 5.5 5.5 6 6 6 D-F5LF 5 9 4 9 4 9 4 10 4.5 10 4 11 6 D-G39, K39 11 D-P5DWL 4.5 4.5 These values are given as guidelines including the hysteresis
Output deviation factor (% F .S.) 0.6 0.5 0.4 Return 0.2 0 0 0.2 0.4 0.5 Out 0.6 0.8 0 25 50 75 1 1 2 3 4 1 5 100 Input signal (%F .S.)
MNB CNA Maximum piston speed: 500 mm/s It can be used at 50 to 500 mm/s provided that it is within the allowable kinetic energy range. (The lock-up cylinder can operate at 50 to 200 mm/s.)
82 54 25 64 8 28 7 50 50 6.6 11 depth 8 1/8 1/8 1/8 24.5 56 28 19 QW 1.8 Stroke 20 32 to 50 20 QU 29 QW 32 to 50 20 32 to 50 20 * Refer to pages 572 and 573 for the auto switch proper mounting position and mounting height. * For the single acting type, a One-touch fitting is on the rod end only. * The position of the width across flats (K) is arbitrary and is not specified. 566 B Stopper
(mm) Model CXS32-10 S SS ZZ Z 10 104 134 40 20 114 144 50 30 124 154 50 40 134 164 50 21-/2210-/11-/12CXS32-20 CXS32-30 CXS32-40 CXS32-50 21-/2210-/11-/1221-/2210-/11-/1221-/2210-/11-/1250 144 174 60 21-/2210-/11-/12100 194 224 90 CXS32-75 CXS32-100 75 169 199 70 21-/2210-/11-/1221-/2210-/11-/12859 Dual Rod Cylinder CXSL 1221CXS / 10-/1122Specific Product Precautions Air Preparation Equipment
Refer to page 829-10. 8-29-17 18 Dual Rod Cylinder: With End Lock For Retraction Side Series CXS 6, 10, 15, 20, 25, 32 How to Order CXS M Y7BW 50 S R 10 Number of auto switches Nil S n 2 pcs. 1 pc. n pcs.
(mm) Overhang L (mm) Graph V = up to 800 mm/s (up to 700 mm/s for 15, 20) 4 CXSJM CXSJL Graph V = up to 600 mm/s 3 CXSJM CXSJL 20 32 0.5 25 1 15 20 0.5 15 Weight m (kg) 10 0.1 10 0.1 6 6 10 20 30 40 50 100 5 10 20 30 40 50 100 5 Overhang L (mm) Overhang L (mm) Note) V = 700 mm/s for 15, 20. 4 Series CXSJ Horizontal Mounting V = up to 400 mm/s V= = up to 800 mm/s V = up to 400 mm/s V= = up
Double wiring specification Symbol D Mounting position 11 12 10 11 10 stations 11 stations D Side 11 stations 12 stations Specified layout Note 2) Specified layout (up to 22 solenoids possible) ... ... ... ...
50% 5mm (INPON )50mm/s 50mm (No.2 ) No. 1 2 2 2 mm/s mm mm/s mm/s mm mm mm mm/s 0 1 ABS 100 100.00 1000 1000 50 40 10 100 0 0 5 2 ABS 50 50.00 1000 1000 0 0 0 100 0 0 0.1 No.1(IN0ON) / DRIVEON No.1 DRIVE No.OUT05OFF IN0 INPOFF PLC BUSYON IN1 DRIVEOFF OUT0 No.1 OUT1 INP INPON BUSY No.1 ON OUT0ON BUSYOFF No.1 No.1 No.2(IN0OFF IN1ON) DRIVEON No.2 0mm 100mm No.OUT05OFF
CJ1 2 to 20 in/s (50 to 500 mm/s) 2 to 20 in/s (50 to 500 mm/s) Piston speed (50 to 500 mm/s) CJP Cushion Air cushion standard Basic style, Foot style, Rod side flange style, Head side flange style, Clevis style, Side tapped style, Center trunnion style, Head side trunnion style, Side lug style, Rod side trunnion style Basic style, Foot style, Clevis style, Rod side flange style, Head side
CJ1 2 to 20 in/s (50 to 500 mm/s) 2 to 20 in/s (50 to 500 mm/s) Piston speed (50 to 500 mm/s) CJP Cushion Air cushion standard Basic style, Foot style, Rod side flange style, Head side flange style, Clevis style, Side tapped style, Center trunnion style, Head side trunnion style, Side lug style, Rod side trunnion style Basic style, Foot style, Clevis style, Rod side flange style, Head side
11 depth 6.5 63 1/4 19.5 10 40 65 55 10 22.4 19 M16 x 2 20 7 52 9 14 depth 8.6 71 1/4 20.5 10 50 71 60 11 28 24 M20 x 2.5 24 8 58 11 17.5 depth 10.8 81 1/4 22 10 63 80 67 13 35.5 30 M27 x 3 33 9 69 13 20 depth 13 97 1/4 25.5 10 80 95 78 17 45 41 M30 x 3.5 36 14 86 15 23 depth 15.2 117 3/8 30 15 100 122 96 26 56 50 M39 x 4 45 21 106 17 26 depth 17.5 142 3/8 36 15 Note 1) Body dimensions are
. 6 10 15 20 25 32 40 6 12 6 CY1L10 15 CY1L20 CY1L25 CY1L32 40 Applicable rodless cylinder 5.5 11 CYP 3.5 7 RB0805 RB1006 RB1411 RB2015 Shock absorber model 5.5 11 Maximum energy absorption: (J) 0.98 3.92 14.7 58.8 5 10 Stroke absorption: (mm) 5 6 11 15 5.5 11 Collision speed: (m/s) 0.05 to 5 4.5 9 Max. operating frequency: (cycle/min) 80 70 45 25 Since the cylinder is in an intermediate
LEC Speed [mm/s] Speed [mm/s] LEC S LEY32m LEY32m for acceleration/deceleration: 2000 mm/s2 90 50 LEC SS-T 80 Lead 4: LEY32C 40 43 Horizontal work load [kg] LEC Y 70 Vertical work load [kg] Lead 4: LEY32C 60 Lead 8: LEY32B 30 Motorless 50 Lead 8: LEY32B 22 40 20 LAT 30 Lead 16: LEY32A 11 20 10 LZ Lead 16: LEY32A 10 0 0 LC3F2 0 300 200 400 100 500 600 0 300 200 400 100 500 600 Speed [mm/s
Standard stroke range (mm) Long stroke range (mm) Bore (mm) TC GB GA F E AL TB C D B1 ZZ A H H1 I J K KA MM NA P S TA WA WB W WH 30 12 12 12 13 14 14 20 20 2 2 2 2 2 2 3 3 12 14 18 25 30 32 40 50 14 11 11 20 25 32 40 50 63 80 100 8 10 12 16 20 20 25 30 18 22 22 30 35 35 40 40 15.5 13 17 17 19 27 27 32 41 10 (12) 35 5 6 6 8 11 11 13 16 26 31 38 47 58 72 89 M4 X 0.7 Depth 7 5 6 8 10 14 18 18
Table 7-1 Quality criteria for clean water (tap water) Item Unit Criterion Circulating fluid Facility water pH (at 25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25 oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulphate ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L] 70 or