9.4.1 HRR050-A-20. 9-11 9.4.2 HRR050-W-20. 9-11 9.4.3 HRR050-A-40. 9-12 9.4.4 HRR050-W-40. 9-12 9.5 Heating capacity . 9-13 9.5.1 HRR050-A/W-20. 9-13 9.5.2 HRR050-A/W-40. 9-13 9.6 Pump capacity. 9-14 9.6.1 HRR050-A/W-20. 9-14 9.6.2 HRR050-A/W-40. 9-14 9.7 Required facility water flow (for water-cooled type) . 9-15 9.7.1 HRR050-W-20. 9-15 9.7.2 HRR050-W-40. 9-15 9.8 Types of Hazard Labels
terminal (D): SYJ5220-D-M5 M8 connector (W0): SYJ5220-W0-M5 Approx. 300 (Lead wire length) Applicable cable O.D. 3.5 to 7 Max. 10 28.1 [35.1] 60.9 53.4 12.7 M8 x 1 32.6 42.1 15.1 39.2 [46.2] Approx. 300 (Lead wire length) Pg7 20 20 20 20 107 [111.4] 3 3 3 3 87.4 [91.8] 105.2 125.2 90.4 77.4 45.4 127 11 11 11 11 23 2-2.6 (For mounting) 2-2.6 (For mounting) 2-2.6 (For mounting) 23 23 23 27
CN1(P.18) 4.2 CN2CN3: LE-CA-CN3 CN2 4.3 CN4I/O 1 CN4 3m 16 - 2 (USB ) 120.3 120.3 mm mm 200 200 mm/s mm/s USB A-miniB type 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN4 4.4 CN5I/O PLC I/O CN5 PLC 6.4 I/O (P.27) 6.3 (P.24) 17 - 5.
CN1(P.18) 4.2 CN2CN3: LE-CP-CN3 CN2 4.3 CN4I/O 1 CN4 3m 16 - 2 USB 120.3 120.3 mm mm 200 200 mm/s mm/s USB A-miniB type 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN4 4.4 CN5I/O PLC I/O CN5 PLC 6.4 I/O P.27 6.3 /(P.24) 17 - 5.
Q 200 VAC 9 50A N.C. S CAC408 50 50A Flange R 230 VAC G N.O.
-/22-CM2R20 11-/22-CM2R25 11-/22-CM2R32 11-/22-CM2R40 25, 50, 75, 100, 125, 150 Relief type Vacuum suction type 1/8 25, 50, 75,100, 125, 150, 200 1/4 Not available 25, 50, 75, 100, 125, 150, 200, 250, 300 Non-lube Double acting, single rod Available Available 25, 50, 75, 100, 125, 150 1/8 25,50,75,100,125,150,200 1/4 25,50,75,100,125,150,200,250,300 Specifications Suction flow rate of vacuum
20 11 22 14 60 60 129 MB-SIO . 100 11 4 \20 90 15 158 132 \84 26 13.5 24 17 75 100 '29 25 +008001 (mm) [~ "r.
Cylinder port is located at U side of body n: Station Max. 16 stations Equation= VQ Dimensions/Side entry connector [FS] (mm) L1=10.5n+14.5 L2=10.5n+25 n L 1 35.5 46 125 135.5 16 15 182.5 193 275 285.5 14 172 182.5 262.5 273 13 161.5 172 250 260.5 12 151 161.5 237.5 248 11 140.5 151 225 235.5 10 130 140.5 212.5 223 9 119.5 130 212.5 223 8 109 119.5 200 210.5 7 98.5 109 187.5 198 6 88 98.5
Series: Servo Motor, Parallel I/O Type: PNP, I/O Cable Length: 1.5m, DIN Rail: DIN Rail, Actuator: Ball Screw Drive, Accuracy: Basic, Size, Motor Mounting and Lead: 16AA [Size 16, Servo Motor (24VDC), 10mm Lead], Stroke: 200mm
Series: Servo Motor, Parallel I/O Type: PNP, I/O Cable Length: 3m, DIN Rail: Screw Mounting, Actuator: Ball Screw Drive, Accuracy: Basic, Size, Motor Mounting and Lead: 16AA [Size 16, Servo Motor (24VDC), 10mm Lead], Stroke: 200mm
Series: Servo Motor, Parallel I/O Type: PNP, I/O Cable Length: 5m, DIN Rail: DIN Rail, Actuator: Ball Screw Drive, Accuracy: Basic, Size, Motor Mounting and Lead: 16AA [Size 16, Servo Motor (24VDC), 10mm Lead], Stroke: 200mm
Series: Servo Motor, Parallel I/O Type: PNP, I/O Cable Length: 5m, DIN Rail: Screw Mounting, Actuator: Ball Screw Drive, Accuracy: Basic, Size, Motor Mounting and Lead: 16AA [Size 16, Servo Motor (24VDC), 10mm Lead], Stroke: 200mm
Series: Servo Motor, Parallel I/O Type: NPN, I/O Cable Length: 5m, DIN Rail: Screw Mounting, Actuator: Ball Screw Drive, Accuracy: Basic, Size, Motor Mounting and Lead: 16AA [Size 16, Servo Motor (24VDC), 10mm Lead], Stroke: 200mm
Series: Servo Motor, Parallel I/O Type: PNP, I/O Cable Length: w/o Cable, DIN Rail: DIN Rail, Actuator: Ball Screw Drive, Accuracy: Basic, Size, Motor Mounting and Lead: 16AA [Size 16, Servo Motor (24VDC), 10mm Lead], Stroke: 200mm
Series: Servo Motor, Parallel I/O Type: NPN, I/O Cable Length: 5m, DIN Rail: DIN Rail, Actuator: Ball Screw Drive, Accuracy: Basic, Size, Motor Mounting and Lead: 16AA [Size 16, Servo Motor (24VDC), 10mm Lead], Stroke: 200mm
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series LECP6 controller has two available modes for the setting software and teaching box. In the easy mode, the operation can be started by only setting the speed, position, etc. Using the normal mode allows a further detailed setup. A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 16, Motor Mounting Position: In-line, Motor: A [Servo Motor (24 VDC)], Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 200mm, Motor Option: w/o Lock, Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Actuator Cable: R (Robotic Flexible Cable
Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 16, Motor Mounting Position: In-line, Motor: A [Servo Motor (24 VDC)], Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 200mm, Motor Option: w/o Lock, Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Actuator Cable: R (Robotic Flexible Cable
Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 16, Motor Mounting Position: In-line, Motor: A [Servo Motor (24 VDC)], Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 200mm, Motor Option: w/o Lock, Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Actuator Cable: R (Robotic Flexible Cable