SMC Corporation of America
Elite Part Number Search
Search Results "11-LEFSH32A-650-R3"

Note 2) The weight is the value for the grommet type. 17-2-33 6 Series VCL Construction q w e r Component Parts t Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Description Material No.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 VXA Clip type VN Ease of maintenance has been improved. Changing of the coil is made easy by means of clip design.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 VXA VN LVC LVA LVH N.O. LVD Variations LVQ Valve Electrical entry LQ OUT Grommet Conduit DIN terminal Conduit terminal LVN Normally closed (N.C.) IN TI/ TIL OUT Normally open (N.O.)

Monitor and Test Mode of the Controller . 51 11. Operation . 53 11.1 Return to origin position . 53 11.2 Positioning operation . 55 11.3.

Wiring 1) Pass them through the cable (7) in the order of cable ground (4), washer (5), rubber seal (6), and then insert into the housing (2). 2) From the terminal block (3), loosen the screw (11), then pass the lead wire (10) through, then again tighten the screw (11). Note) Tighten within the tightening torque of 0.5 Nm 15%. Note) Cable (7) external: 6 to 8 mm 3.

650 650 1080 1080 1080 1300 1300 1268 1258 1978 2278 1550 2160 2770 2558 3288 1000 945 1340 1340 1100 1550 1650 1700 1700 550 645 740 740 750 750 750 850 850 6 9 9 9 12 12 12 16 16 460 665 693 693 1162 1162 1162 1416 1416 19 19 19 19 19 19 19 27 27 80 M16 x l 250 M16 x l 250 M16 x l 250 M16 x l 300 M16 x l 300 M16 x l 300 M16 x l 500 M24 x l 500 M24 x l 500 AT6C AT11C AT22C AT37C AT55C AT75C

CH.B Channel 10 [ms] 10 [ms] CH.A Time GND CH.SELECT terminal 10 [ms] 10 [ms] Disconnected Time 16-13-11 19 Technical Information 2-wire pressure switch connections 14 Voltage and current output pressure sensors 15 A 3-wire type switch is a switch that has an output line other than the positive and negative lines that supply the electricity.

The EEPROM is rated to keep its memory for 100,000 hours (approx. 11 years) without having power supplied. When system performance declines due to filter element clogging, worn vacuum pads, piping leakage, etc., the switch can detect and indicate an oncoming problem before failure occurs.

Rc 1/8 7 to 9 Rc 1/4 12 to 14 Rc 3/8 22 to 24 Rc 1/2 28 to 30 Rc 3/4 28 to 30 Rc 1 36 to 38 Rc 11/4 40 to 42 Rc 11/2 48 to 50 Rc 2 48 to 50 Reference How to tighten M5 threads on the fittings After tightening by hand, use a tightening tool to add about 1/6 turn more. But when using miniature fittings, after tightening by hand, use a tightening tool to add 1/4 turn more.

P . 14-20-57 14-20-42 2 Odor Removal Filter Series AMF How to Order AMF150 to AMF850 AMF 250 03 R B Option R IN-OUT reversal direction Body size Bracket Accessory (Option) 150 Standard 1 8 250 Standard 1 4 350 Standard 3 8 450 Standard 1 2 550 Standard 3 4 650 850 B 1 4 B 3 8 04 B 1 2 06 B Nil Nil B Piping port (B dimension) 1 Standard 11 2 Standard 01 B 1 8 02 03 Thread type Nil Rc F G N

VVZ200-32A-11 pc. VVZ400-32A-11 pc. Caution Refer to pages 5-11-2 to 6 for Safety Instruction and Solenoid Valve Precautions. VV3ZA2-50-031-01 1 pc. VV3ZA4-50-031-021 pc. VZA214-P2 pcs. VZA414-2P2 pcs. VVZ200-31A-11 pc.

equivalent (130C) (6) 51 45 17 (5.3) 11 (2.9) 5.5 50 Hz 60 Hz 50 Hz 60 Hz Inrush Apparent power (VA) (Power consumption (W)) VP AC Holding S070 Power consumption (W) DC Bracket (AXT338-11)/For body ported type VQ Accessory (Option) Indicator light Body ported Manual override VKF Note 1) Based on JIS B 8375-1981.

P port(Supply port)Supply pressure fitting (0.55 to 0.8 MPa) R1,R2,R3(*1) ports(Exhaust port)Silencer *1 A small amount of air in the cover tube is exhausted from R3 port. *2 Ports FA and FB are plugged before shipment.

Applicable stroke table Size Stroke [mm] 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1100 1200 25 32 40 25 - .

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Compact: Single valve volume reduced by 15% (Class 3) VX3 VXA Clip type VN Ease of maintenance has been improved. Changing of the coil is made easy by means of clip design.

850 J Drain guide B female thread R IN-OUT reversal direction Symbol Description Bracket T Element service indicator Nil B N.C. auto-drain C 1 Standard 11 2 Standard N.O. auto-drain D Note) Refer to How to Order Bowl Assembly on page 1420-59.

Do not disassemble or modify the main body. 16-11-3

VXA VN LVC LVA LVH LVD LVQ LQ LVN TI/ TIL PA PAX PB 17-4-35 6 Series VNH Construction 12 8 12(P1): External pilot port 10(P2) : Pilot EXH port Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10 3 3 7 7 4 8 11 4 5 11 10 1(P) Port 2(A) Port P Port A Port Valve element

Applicable Auto Switch/ Refer to Best Pneumatics Vol. 11/12 for further infomation on auto switches.