SMC Corporation of America
Elite Part Number Search
Search Results "22-MXQ16-50C"

Coolant (water-soluble) Compatibility with polyester: OK Compatibility with stainless steel 304: OK Compatibility with NBR (FKM): OK 50C 80C or less: OK 0.3 MPa 0.5 MPa or less: OK Check the compatibility of fluid with vessel material [stainless steel 304/ carbon steel].

During operation: 36F (2C) to 113F (45C) During storage: 32F (0C) to 122F (50C) (when there is no drain water inside of the piping) Avoid locations where temperature substantially changes. Avoid locations where strong magnetic noise occurs. (Avoid locations where strong electric fields, strong magnetic fields, or surge voltages occur.)

ARP30-02BG-3 1.4 L/min (ANR) or less (at P2 = 0.6 MPa) Pressure port size Note 3) 1/8 1/4 1/8 5 to 60C (No freezing) Ambient and fluid temperature With digital pressure switch 5 to 50C (No freezing) Ex.)

ARP30-02BG-3 1.4 L/min (ANR) or less (at P2 = 0.6 MPa) Pressure port size Note 3) 1/8 1/4 1/8 5 to 60C (No freezing) Ambient and fluid temperature With digital pressure switch 5 to 50C (No freezing) Ex.)

(mm) Voltage(V) 10% 15 2200 300 Single100 55/65 37 5700 350 X 2 3-phase200 132/170 X 2 1.44/1.4 11/2B union 55 22 3300 400 3-phase200 90/130 0.4/0.45 B union 36 Single200 38/46 3-phase200 50/60 Cooling fan (50/60Hz) Power consumption (W) Current (A) 0.46/0.52 0.23/0.26 Rp(PS) Socket 18 0.8/0.9 0.4/0.35 1B union 24 11 2 Port size Weight (kg) 3 4 Compact size and light weight Note 1) Based

Standard Specifications Valve construction Rubber seal Metal seal Fluid Air, Inert gas Air, Inert gas 0.7MPa (High pressure type: 0.8MPa) Max. operating pressure Single 0.15MPa 0.1MPa Minimum operating pressure Double (latching) 0.18MPa 0.18MPa 3 position 0.2MPa 0.1MPa 10 to 50C Note 1) Ambient and fluid temperature Lubrication Not required Push type/Locking type (slotted type, knob type)

Air, inert gas Fluid 0.6 MPa Maximum operating pressure 0.3 MPa Minimum operating pressure 5 to 50C Ambient and fluid temperature Not required Lubrication Manual override Non-locking push type / Lock type (tool type) Push-lock type Non-locking push type / Lock type (tool type) Rated coil voltage DC12, 24 V DC12, 24 V, AC100, 110, 200, 220 V DC 1W 1W 0.5W 100 V AC 0.6VA (6mA) 0.5 VA (5 mA)

pressure range 5 to 50C Ambient and fluid temperature 10 to + 10% Allowable voltage fluctuation Grommet : G, H L type plug connector : L, LN, LO M type plug connector : M, MN, MO Electrical entry 0.5W (with light: 0.6W) : Series ZYY3000 0.6W (with light: 0.65W) : Series ZYX3000 Power consumption Effective area (Cv factor) 4.68mm (0.26) Series ZYX3000 4 Series ZYY/ZYX Electronic Vacuum

; rubber seal -5 to 50C, Optional IP65 enclosure, TIE RODS, STATION 22, VALVE, VV5Q41 NO SIZE RATING, .03306 lb

; rubber seal -5 to 50C, Optional IP65 enclosure, VV5Q41 NO SIZE RATING, VALVE, "VV5Q41 MFLD, VQ4000 4/5-PORT ", 22, N lb

; rubber seal -5 to 50C, Optional IP65 enclosure, EXHAUST SPACER, VALVE, VV5Q41 MFLD, VQ4000 4/5-PORT, 22, VV5Q41 NO SIZE RATING, 0.242 lb

; rubber seal -5 to 50C, Optional IP65 enclosure, EXHAUST SPACER, VALVE, VV5Q41 MFLD, VQ4000 4/5-PORT, 22, VV5Q41 NO SIZE RATING, 0.242 lb

(Spring return) Operation Internal pilot External pilot Operating pressure range 36 to 102 psi [0.25 to 0.7 MPa] 36 to 102 psi [0.25 to 0.7 MPa] External pilot pressure 0.25 to 0.7 MPa (Same as operating pressure) Maximum operating frequency 30 times/minute Minimum operating frequency 1 time/week Operating and ambient temperature 14 to 122F [10 to 50C] (No freezing) Ambient humidity 20 to

Ambient and fluid temperature operation is as follows: Digital pressure switches: 0 to 50C Other pressure switches: 0 to 60C Take measures to prevent moisture from freezing in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.

VDC (Within rated differential pressure range) Output impedance: Approx. 1 k Output specification Accuracy (Ambient temperature of 25C) Linearity Repeatability Indication light Enclosure Operating temperature range Operating humidity range Withstand voltage Insulation resistance 1% F .S. or less 0.5% F .S. or less 0.3% F .S. or less Orange light is on (When energized) IP40 Operating: 0 to 50C

Proper tightening torque (Nm) 7 to 9 12 to 14 22 to 24 28 to 30 28 to 30 36 to 38 Thread 1/8 1/4 3/8 1/2 3/4 1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2.

Note 3) Standard Specifications Metal seal Rubber seal Seal Air, Inert gas Air, Inert gas Fluid Symbol 1.0MPa (3) Max. operating pressure Single 0.20MPa 0.15MPa Valve specifications Solenoid specifications 2 position single 3 position double check Min. operating Double 0.15MPa 0.15MPa (A) 4 (B) 2 (A) 4 (B) 2 pressure 3 position 0.20MPa 0.15MPa (1) (1) 5 to 50C 10 to 50C Ambient and fluid

-20 -20 10 Maximum suction flow Suction flow (l/min(ANR)) 25 20 15 10 5 0 0.1 0 0.2 0.3 0.4 0.5 0.6 Supply pressure (MPa) 13-9-3 4 Series ZQ Specifications Ejector Weight Switch and suction filter Note 2) 95 g Model Suction filter Note 1) ZQ107 ZQ105 ZQ110 Single unit 109 g Nozzle nominal diameter mm 0.7 0.5 1.0 End plate assembly for manifold 122 g Maximum suction flow l/min(ANR) 10 5 22

Recommended Tightening Torque [Nm] Connection thread Pressure Control Equipment 1/2 3/8 1/4 1/8 Torque 28 to 30 22 to 24 12 to 14 7 to 9 2. Avoid excessive torsional moment or bending moment other than those caused by the equipments own weight as this can cause damage. Support external piping separately. 3.

Specifications Type of actuation Direct operated type 2 position single solenoid Fluid Air 5 to 50C (No freezing) Ambient and fluid temperature Response time (at 0.5 MPa) (1) 10 ms or less (Standard), 15 ms or less (Low power consumption type) Non-locking push type Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)