Body Size: 20, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 80µ, Water Removal Type: Large Flow Type, Semi-standard: Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F)

Body Size: 20, Pipe Thread: N (NPT), Port Size: 02 (1/4), Mounting: B (w/Bracket), Nominal Filtration Rating: 80 (80µ), Water Removal Type: T (Large Flow Type), Semi-standard: Z (Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F))

Body Size: 20, Pipe Thread: N (NPT), Port Size: 01 (1/8), Mounting: B (w/Bracket), Nominal Filtration Rating: 80 (80µ), Water Removal Type: T (Large Flow Type), Semi-standard: Z (Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F))

Body Size: 20, Pipe Thread: N (NPT), Port Size: 02 (1/4), Mounting: w/o Mounting Option, Nominal Filtration Rating: 40 (40µ), Water Removal Type: T (Large Flow Type), Semi-standard: Z (Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F))

Body Size: 20, Pipe Thread: N (NPT), Port Size: 02 (1/4), Mounting: B (w/Bracket), Nominal Filtration Rating: 40 (40µ), Water Removal Type: T (Large Flow Type), Semi-standard: Z (Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F))

Body Size: 20, Pipe Thread: N (NPT), Port Size: 01 (1/8), Mounting: B (w/Bracket), Nominal Filtration Rating: 40 (40µ), Water Removal Type: T (Large Flow Type), Semi-standard: Z (Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F))

Body Size: 20, Pipe Thread: N (NPT), Port Size: 02 (1/4), Mounting: w/o Mounting Option, Nominal Filtration Rating: 80 (80µ), Water Removal Type: T (Large Flow Type), Semi-standard: Z (Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F))

Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm. When tightening, do not hold the Z/ISE20 body with a spanner. Pressure second or longer simultaneously.

Body Size: 20, Pipe Thread: NPT, Port Size: 1/8, Mounting: w/o Mounting Option, Nominal Filtration Rating: 80µ, Water Removal Type: Water Drop Removal Type, Semi-standard: Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F)

Body Size: 20, Pipe Thread: NPT, Port Size: 1/8, Mounting: w/o Mounting Option, Nominal Filtration Rating: 40µ, Water Removal Type: Water Drop Removal Type, Semi-standard: Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F)

Body Size: 20, Pipe Thread: N (NPT), Port Size: 01 (1/8), Mounting: w/o Mounting Option, Nominal Filtration Rating: 80 (80µ), Water Removal Type: S (Water Drop Removal Type), Semi-standard: Z (Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F))

Body Size: 20, Pipe Thread: N (NPT), Port Size: 01 (1/8), Mounting: w/o Mounting Option, Nominal Filtration Rating: 40 (40µ), Water Removal Type: S (Water Drop Removal Type), Semi-standard: Z (Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F))

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector), Option: S (Bracket for w/Flow Adjustment Valve)

Nil Without lead wire M5 female thread ZS-46-A1 ZS-46-3L M5 Lead wire with connector (3-core, 2 m lead wire) A1 Bracket A (Vertical mounting) Piping port L Without waterproof cover R1/8 ZS-46-A2 01 R1/8 Piping adapter ZS-46-N1 A2 Bracket B (Horizontal mounting) u Option 3 Symbol Operation manual1 Calibration certicate1 Nil Y K T NPT1/8 N01 NPT1/8 Piping adapter ZS-46-N2 1 All texts

Series AF modular style air filter is a cost effective, clean looking solution to your filtration needs. Its' modular design allows connection with other SMC air preparation equipment. The series is available in six size options with a wide range of accessories.Modular air filter , Prevents contamination , Lighter weight than old style modular AF , Thickness reduction of resin case provides