SMC Corporation of America
Elite Part Number Search
Search Results "AL30-03-6-A"

(Example) When Step Data No. 1 is used for a positioning operation: Recommended set value Set value for pushing speed = 6 (Thus, positioning speed of Return to Origin: 6 mm/s, Pushing speed for Step Data No. 1 positioning operation: 0 mm/s) 45 - (Example) When Step Data No. 1 (Step Data No. 0) is used for a pushing operation and the speed is set to 6 mm/s: Recommended set value Set value

1.5 22.5 9.5 2-5.5 (Mounting holes) 71.2 (GZ, GS: 71.9) [72.9] 6 21.5 26 50.3 X R A A A A P SY 43 SYJ 4-Rc (PT)1/4 (Lead wire length) VK (P/R port) G: 300 H: 600 VZ (Pitch) L1 L2 P=19 15 6 VT Manual override Depress and turn to operate and lock override.

A Note 1) 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12

48.5 63.6 25 89.5 79.5 10 15 ZPR40D 40 43 29 42.5 53.3 71.1 25 97 87 17 15 A P P L I C A B L E T U B E A P P L I C A B L E T U B E Applicable Tube OD P Q R S Applicable Tube OD P Q R S 4 4 23.3 15.8 10.4 6 6 24.3 16.8 12.8 H O W T O O R D E R Z P R P A D H O R I Z O N T A L T Y P E W I T H O U T B U F F E R 6 6 24.3 16.8 12.8 8 8 26.2 18.7 15.2 8 8 26.2 18.7 15.2 ZPR P A D D I A M E T E

A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8

A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8

-06SK 17 25.2 18.4 34 6 12.8 37 42.6 14 R 1/4 14 41.2 46.2 47.2 52.2 18.5 AS231FE-02-08SK 12.9 18.5 28.2 18.3 35.2 8 15.2 39 45.6 AS231FE-02-10SK 21 31 20.2 38.7 10 18.5 42 48.4 AS331FE-03-06SK 17 25.2 38.5 6 12.8 57 46.1 20.6 12.9 AS331FE-03-08SK 18.5 28.2 39.7 8 15.2 60 49.1 14 R 3/8 19 46.5 51.5 52.8 57.8 23 AS331FE-03-10SK 21 32.6 43.7 10 18.5 62 53.5 23 16.2 AS331FE-03-12SK 22 34.4 44.9

Note 1) Same as standard product except for cover assembly Note 2) 03, 04, and 06 indicate the relevant port sizes (Rc3/8, 1/2, 3/4). 108 108 AIR VENT M6 x P1 G1/2 AIR VENT M6 x P1 2 x RcD 2 x RcD C B A B OUT IN OUT IN C A DRAIN G1/4 DRAIN G1/4 (mm) (mm) A B D C A B D C Model Element length Model Element length A (L250) A (L250) 314 70 374 314 70 407 FGDC FGDE FGDC FGDE B (L500) B (L500)

Inch size Metric size Port size 4 04 03 5/32 M5 M5 x 0.8 Thread type 6 06 07 1/4 U10/32 10-32 UNF 8 08 09 5/16 Metric thread (M5) 01 1/8 Nil 10 10 11 3/8 Unified thread (10-32 UNF) 02 1/4 12 12 13 1/2 R 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tubing O.D./Port Size Combinations From male thread to One-touch fitting A Metric size Inch size Applicable tubing O.D.

When operating 6 or more valve stations within a manifold at the same time, take SUP air pressure from both sides and open EXH port to the atmosphere. 2. When manifolding an exhaust center 3 position valve, use the individual EXH style manifold. (Back pressure may cause actuator to malfunction.) 3-9-5 6 Series VVS410 Construction Replacement Parts: Sub-assembly No.

ASG22F-M5-04 ASG22F-M5-06 ASG32F-01-04S ASG32F-01-06S ASG32F-01-08S ASG42F-02-06S ASG42F-02-08S ASG42F-02-10S ASG52F-03-08S ASG52F-03-10S ASG52F-03-12S ASG62F-04-12S 4 10.6 23 28.8 11.6 25.2 18.2 M5 x 0.8 8 15.8 37.2 33.7 33.7 30.2 6 13 23.6 30.6 14 34.4 18.8 4 10.6 24.8 32 14.3 39.4 18.2 1/8 12 18.6 44 39 40 35 6 13 25.4 32.6 14.3 42.4 18.8 8 15 27.5 35.5 16 52.4 20.9 6 13 27.3 36.2 17.9

Port 2 (A) pressure (MPa) Port 2 (A) pressure (MPa) 0.8 0.8 0.8 0.7 0.7 0.7 0.6 0.6 0.6 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 VY1D00-5 VY1B0-5 VY120-5 1 0 1 2 3 4 5 0 1 2 3 4 5 V V V 0 1 2 3 4 5 A VY1D00-6 VY1B0-6 VY120-6 A 1 1 1 1 0 2.5 5 7.5 10 0 2.5 5 7.5 10 V V V 0 2.5 5 7.5 10 VY1D00-7 VY1B0-7 VY120-7 1 A 4 0 8 12 16 20 mA 4 0 8 12 16 20 mA 4 0 8 12 16 20 mA 2 2

Hs Auto switch 24.5 A B 49.5 A 33 B Proper auto switch mounting positions (mm) D-G39 D-K39 D-A3 D-A44 D-H7 D-H7C D-H7W D-H7BAL D-C7 D-C80 D-C73C D-C80C D-B5 D-B64 D-G5NTL D-H7F D-B59W Bore size (mm) A B A A A A A A B B B B B B 16 15.5 7.5 12 14 17.5 12.5 11 19 20 8 4 6 9.5 4.5 25 17.5 13.5 17 7 15.5 19 10.5 14 20.5 7.5 3.5 5.5 9 4 32 20.5 16.5 9 20 18.5 22 23.5 12.5 17 9.5 5.5 7.5 11 6 40

L ZY O L ZF G H F ZP K J SP ZCUK B C E D I A 2 x 4.5 AMJ AMV AEP HEP Related Equipment A B C D E F G H I J K L Model ZFC050-02 ZFC050-23 ZFC050-04 ZFC051-01 ZFC051-03 58.5 12.75 12.75 2 3.2 33 25 10 10.5 10.5 12 8.5 13.75 4 58 12.5 12.5 1/8" 5/32" ZFC100-04 4 ZFC100-06 6 30 10 18 11.6 19.5 23 20 29 53.2 9.1 14.1 ZFC101-03 5/32" ZFC101-07 1/4" ZFC200-06 6 ZFC200-08 8 34 14 22 15.6 23.1 27

Rc 3/8 Rc 1/2 VBA2100-03 VBA4100-04 20 14-9-6 7 Booster Regulator Series VBA1110 to 4200 Air Operated Type VBA2200-03, VBA4200-04 I Pressure gauge (Option) Pilot port IN port F.R.L.

4 1.1 x 8 R 1/4 R 1/4 R 1/4 R 1/4 14 14 14 14 20 20 20 20 14 14 14 14 D 2 A Connection thread H1 L1 Copper extension nozzle: KNL (mm) Model Nozzle size D Outside diameter L1 Outside diameter KNL3-06-150 KNL3-06-200 KNL6-06-150 KNL6-06-200 1.5 2 1.5 2 6 6 6 6 300 300 600 600 D L1 Note) When a copper extension nozzle is ordered separately, a self-align fitting will also be required for connection

-k~-+---F'-i a. ~ " Ci Ora e mark ~ 8 0.2i=--l-t--':=-I:---+-f>__j ~ 8 0. 15 % ~-2~ 0 ~ 0-~ 4~ 00 ~-~ 6~ 00 ~-~ 80 ~0-~ 1 ~ 00 ~ O --j 0 'Ji 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Flow rale / min (ANR ) Inlel pressure MPa 8Turning the adjusting handle clockwise increases the pressure and turning the handle counterclockwise reduces the pressu re. AR2501-03 AR2501-03 0 I !

VVEX2-2-5-02 VEX1233-G VEX1-17 4 pieces 1 piece Set Pressure Characteristics (Air operated type) Set Pressure Characteristics (Manual handle type) A port pressure (MPa) A port pressure (MPa) Signal port PA Pressure (MPa) Handle rotation (Cycles) 14-6-5 6 Series VEX130 3 Flow Characteristics P port pressure: 1 MPa VEX1A33, VEX1B33-01 VEX1130 3, VEX1230 3-02 VEX1330 3-03 A port pressure (MPa

F(mm) Port B min. port size Weight (g) L1 L2 L3 L4 L5 L6 P Q1 Q2 M KM12-04-02-6 6 17 89 110 99 125 108 139 40 67 75 84 96 100 117 1 4 4 10 18 29.5 19.5 29 10.6 16 6 12 KM12-04-02-10 10 KM12-06-02-6 6 KM12-06-02-10 10 KM12-08-03-6 6 KM12-08-03-10 10 61.5 47 1 4 6 17 10 19.5 31.5 21.5 31 13 17 7.5 13.5 73 55 3 8 8 19 11.5 22.5 35.5 24 34.5 15.5 18.5 9 14.7 86 63 Series KM One-touch Fittings