SMC Corporation of America
Elite Part Number Search
Search Results "AL50-06-2-A"

Model symbol (In-line filters) Element size 125mm 65 x 250mm Bore size 04 06 Rc 1/2 Rc 3/4 2.

Quick exhaust Normal operation High speed supply B 1/2 PP PA C D PP PA 1(P) 2 2(A) 1 1/2 PP = approx.

-04 90 1 2 AN500-06 160 3 4 Note) NPT thread is also available.

Adjustment procedure is shown below. 1) Insert a wrench into the hexagon hole of the adjustment screw to loosen lock nut A. 2) Rotate the adjustment screw to right and left and move the cushion ring holder (stroke end) forward and backward to align the position with that of the external stopper. 3) After the stroke end adjustment is completed, retighten lock nut A. 3.

LVA Refer to the table (2) given below for availability. Port size 04 06 10 12 14 20 LVH 1 2 3 4 Refer to page 17-3-16 for ordering coil only. 1 1 1 2 LVD 1 4 1 2 Thread type Nil T F N LVQ Rc NPTF G NPT Refer to the table (1) given below for availability.

VHS20/30 VHS40/40-06/50 2-10 I 10 I G H F E X H .

) 01 32 02 36 30 31 35 30 03 33 30 0D 2 Set at +1.50 deg.C 06 32 0D 37 Temperature setting (with writing EEPROM) F 01 3F 02 37 32 35 30 30 03 33 3F 0D 06 3F 0D Set at 25.0 deg.C 38 Offset setting (with writing EEPROM) F 01 3F 02 38 30 31 35 30 03 33 3F 0D 06 3F 0D Set at +1.50 deg.C HEC 6-1

When "A" is turned ON, output goes ON. 2. The output ON state is maintained even if "A" is turned OFF. 3. The output goes OFF when "B" is turned ON in condition 2. Interlock circuit When either "A" or "B" are ON, output 3 does not go ON even if "C" is turned ON. Output 3 goes ON if "C" is turned ON, only when both "A" and "B" are OFF.

(With 2 input blocks) With external pilot specification 46.5 (Pitch) 15.8 9.5 16.5 20.5 17.5 P = 16 M3 M12 11.9 9.2 17.7 25.2 30.6 3 3 4 A 4 A 4 A 4 A 4 A 3 3 3/5 E PWR 49.9 42.7 4 A 4 A 4 A 4 A 4 A E 3/5 3/5 E PWR 2 2 E 3/5 63.5 2 2 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 1 1 1 1 1 P P 1 BUS 0 P 1 1 P BUS 0 0 0 X PE PE x One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 4, N3 6

Caution REC25 101110-AS2001F-06-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC32 101110-AS3001F-08-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC40 101110-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 2. Speed control is possible with meter-in and meter-out types of speed controllers.

How to Order VR 12 1 06 0 F Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 2 1/8 standard 1/4 standard 23 04 06 08 10 01 03 07 09 11 3.2 4 6 8 10 1/8" 5/32" 1/4" 5/16" 3/8" With One-touch fitting Use 1/8" tubing for 3.2. 1 Series VR120F Application Circuit Examples Self holding circuit 1. When "A" is turned ON, output goes ON. 2.

Flow Direction Symbols on Body Meter-out type Meter-in type Symbol JIS Symbol 15-9-57 2 Series AS-FM How to Order AS 2 2 0 1 F M 01 06 Body size Option 1 2 M5 standard 1/8, 1/4 standard Nil S None With seal M5 and U10/32 are not available with seal. Type 2 3 Elbow Universal Applicable tubing O.D.

Standard stroke range (mm) Long stroke range (mm) Bore size (mm) B1 A C D E F GA GB H H1 I J K KA MM NA P S TA TB TC ZZ WA WB WH W CS1 AL 30 18 22 22 30 35 35 40 40 15.5 13 17 17 19 27 27 32 41 14 8 10 12 16 20 20 25 30 2 2 2 2 2 2 3 3 12 12 12 13 14 14 20 20 10(12) 35 5 6 6 8 11 11 13 16 26 M4 x 0.7 depth 7 5 6 8 10 14 18 18 22 26 M8 x 1.25 11 11 11 12 13 13 11 M5 x 0.8 106(114) 16 15(

l/8 a a a a a 3/8 a a a 1/2 a 3t4 a a a a Note 2) For M5 and NPT thread lypes Accessories Wrlh o?

Flow Rate Characteristics Series AV2000-A AV3000-A AV4000-A AV5000-A Port size 1(P), 2(A) 1/4 3/8 1/2 3/4 1 3(R) 1/4 3/8 1/2 3/4 1(P) R 2(A) C[dm3/(sbar)] 9.2 13.1 19.2 34.8 41.3 b 0.36 0.27 0.32 0.66 0.34 Cv 2.4 3.1 5.1 12.6 13.7 Flow rate characteristics 2(A) R 3(R) C[dm3/(sbar)] 8.8 9.2 10.1 23.7 b 0.46 0.48 0.55 0.67 Cv 2.5 2.6 3.2 9.2 Pressure for switching from low speed air supply

1 Quick Exhaust Valve Series AQ Model Excellent exhaust characteristics Large flow capacity Compact and lightweight A wide selection of models Port size Effective area (mm2) Weight (g) Model IN OUT OUT EXH M5 x 0.8 AQ1500-M5 AQ1510-01 AQ2000-01 AQ2000-02 AQ3000-02 AQ3000-03 AQ5000-04 AQ5000-06 2 4 25 35 40 60 105 135 2.8 5.8 25 40 42 70 115 180 25 45 110 105 215 205 690 650 1 8 1 8 1 4

Port size P, A port R port Model Effective area (mm2) (Cv) Flow characteristics C (dm 3/(sbar)) to VEX3 20 1 3 1 8 1 2 160 to 670 160 to 670 160 to 670 2.4 to 9.8 Air operated 1 2 24 VEX3 00 5 7 9 3 4 to 2 VEX3 21 1 3 to 1 8 1 2 2.4 to 9.8 Body ported External pilot solenoid valve 24 1 2 to 2 3 4 VEX3 01 5 7 9 VEX3 22 1 3 to 1 8 1 2 2.4 to 9.8 Internal pilot solenoid valve 24 1 2 to 2 3

Dimensions inch (mm) AK3542 & 4542 M5 x 0.8 Actuation port 1.57 (40) 2.24 (57) 2 x Compression 2 x R, NPT male 2 x Rc, NPT female 0.44 (11.2) B B A A A Connections: N, BRN Connections: 4T, 6T Connections: 4, 6, BR 4 6 4 6 4 6 Ports A B Connections inch (mm) inch (mm) 4T 2.56 (65.0) 1.12 sq. (28.4) 1/4 inch compression 4BR 1.70 (43.2) Rc 1/4 4BRN 2.32 (58.9) 1.12 sq. (28.4) R 1/4 4 1.70

Note 2) The value at a temperature of 68F (20C).