Clearance For Maintenance W E G A AC-B AA M J N F (2) P1 (Port Size) C B Q Q V IN OUT K P2 (Gauge Port Size) Bracket and Relief Valve (Optional) U Min.

2 (A) 4 (B) 2 (A) 4 Flow Rate Characteristics/Weight 5 (R1) 1 (P) 3 (R2) 1 (P) 3 (R) Flow rate characteristics Operating pressure range (MPa) Weight (g) 4/2 5/3 (A/B R1/R2) Port size 1 4/2 (P A/B) Mounting with VK300 Valve model C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv Grommet VV061 The VK300 series can be mounted on the same manifold base VV5K3 of VK3000 series.

C (mm) Proper mounting position Proper mounting position Proper mounting position D-M9 D-M9W D-M9V D-M9WV D-M9 D-M9W D-M9V D-M9WV D-M9 D-M9W D-M9V D-M9WV Model Model Model A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E 16.5 25 4.5 18.5 49 6.5 7.5 38 21 MIW8-8D MIS12

END 5 Booster Regulator Series VBA Working Principle The IN air passes through the check valve to booster chambers A and B. Meanwhile, air is supplied to drive chamber B via the governor and the switching valve. Then, the air pressure fromdrive chamber B and booster chamber A are applied to the piston, boosting the air in booster chamber B.

Plug that A port to avoid mistaking B port for the A port.

so that an even number will be allocated. a) I/O mapping Auto mapping/fixed mapping Fixed mapping Available 16, 128 to 1280 points (2, 16 to 160 bytes) Increase and decrease by 128 points (16 bytes). b) System input 1280 points/ 160 byte Available This is not settable when the I/O mapping is set to "Auto". size 16, 128 to 1280 points (2, 16 to 160 bytes) Increase and decrease by 128 points

M5 x 0.8 b Cv b Cv VV3Z1-01-1 VV4Z1-20-1 1/8 How to Order Manifold Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no.

The converter will be 160 to 300. To obtain the capacity of the converter, multiply the cylinder displacement by approximately 1.5. Note: Select the nominal diameter of the converter so that the converter's oil level speed does not exceed 0.2m/s.

For pipe fitting 4B through 6B Applicable fittings For pipe fitting 3/4B through 3B Welding Welding Piping B Reducing tees B 1 1 x 1 x 1 24 or more 11/4 11/2 11/4 x 11/4 x 1 1B socket 11/2 x 11/2 x 1 cut in half 2 x 2 x 1 2 21/2 x 21/2 x 1 21/2 3 x 3 x 1 3 Pipe 4B through 6B Reducing tees B Socket Pipe : JIS B 2301 : JIS B 2302 : JIS B 3452 Without flash 16-12-8 Paddle Style Flow Switch Series

1396.5 1006 1070 14 5 1000 80 11-LEJS63S-12001556.5 1596.5 1206 1270 16 6 1200 80 11-LEJS63S-15001856.5 1896.5 1506 1570 18 7 1400 180 536 LEJ Series Auto Switch Mounting Auto Switch Mounting Position (C) B (Table center) A [mm] Model Size A B C Operating range LEJS 40 77 80 160 5.5 LEJB 5.0 LEJS 63 83 86 172 7.0 LEJB 6.5 Note) The operating range is a guideline including hysteresis, not

Specifications Model XLDV-25 XLDV-40 XLDV-50 XLDV-63 XLDV-80 XLDV-100 XLDV-160 Flange (valve) size 25 40 50 63 80 100 160 Actuating type Normally closed Fluid Vacuum of inert gas Operating temperature oC 5 to 60 Operating pressure Pa Atmospheric pressure to 1 x 10-6 Main pumping 14 45 80 160 200 300 800 Conductance l/s Note 1 Initial pumping 0.53 28 2.511 48 418 6.531.5 6.531.5 Internal 1.3

C D A B (mm) D-A9, D-A9V (mm) D-F9, D-F9V (mm) D-F9W, D-F9WV A B A B A B Bore size 16 25 32 Operating range Bore size 16 25 40 Operating range Bore size 16 25 40 Operating range 54 106 58 102 57 103 54 156 58 152 57 153 11 8.5 8.5 85 245 89 241 88 242 (mm) (mm) (mm) C D C D C D Bore size 16 25 32 Operating range Bore size 16 25 32 Operating range Bore size 16 25 32 Operating range 27 133

(ASME B40.1 Grade B or better) psig/bar 4) (No code) Accuracy Cleanliness No oil ASME B40.1 level IV No oil Brass Polycarbonate Brass Phosphor bronze B Case Window Socket Bourdon tube Material MPa MPA 1.14 (29) 2.28 (58) 2.1 (53.5) 2.12 (54) NPT 1/4 0.42 (10.5) inch (mm) 3) Part number of pressure gauge itself.

Proper Auto Switch Mounting Position (Detection at stroke end) C D A B D-A9, D-A9V D-M9, D-M9V, D-M9W, D-M9WV B B Series model A Series model A Operating range Operating range MY2C16 MY2C16 44 116 48 112 MY2H16 MY2H16 46 114 50 110 MY2HT16 MY2HT16 11 8.5 70 90 74 86 MY2C/H/HT25 MY2C/H/HT25 54 156 58 152 MY2C/H/HT40 MY2C/H/HT40 85 245 89 241 Series model C Series model C D D Operating range

Proper Auto Switch Mounting Position (Detection at stroke end) C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Series MY2C Series MY2H Series MY2HT (mm) D-M9, D-M9V (mm) D-M9, D-M9V (mm) D-M9, D-M9V A A A B B B Bore size 16 25 40 Operating range Bore size

, 3/5(E) port] Applicable tube O.D.: 10, 3/8" 8 DIN rail 5.5 PE B A B A B A B A B A A 4 3/5 A 4 A 4 A 4 A 4 35 (114.8) 97.5 113.4 116.7 39.5 26.5 E X 101 1 81.2 61.7 Cm: 14.5 01: 16.2 P 47.3 5.5 B 2 B 2 B 2 B 2 B 2 4 x M5 mounting hole 1.4 10.9 2.7 4.7 1/8 [4(A), 2(B) port] SI unit L2 34.2 1.5 One-touch fitting [4(A), 2(B) port] L4 (DIN rail mounting hole pitch: 12.5) 5.3 Applicable tube

4 A 62.1 41.7 25.7 39.4 (58) 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 20.9 P 1 P=17.5 94.9 76.2 7.5 One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 4 : 6 : 8 L n Dimensions Formula: L1 = 17.5n + 52, L2 = 17.5n + 106 n: Stations (Maximum 16 stations) 16 332 386 412.5 423 15 314.5 368.5 400 410.5 14 297 351 375 385.5 13 279.5 333.5 362.5 373 12 262 316 337.5 348 11 244.5 298.5 325 335.5