SMC Corporation of America
Elite Part Number Search
Search Results "CDJP2B4-5D-B-M9BV"

): Dimension of the D-A96 D-A9V D-M9V D-M9WV D-M9AV Auto switch Auto switch Hs Hs A B A B 21.5 (23.5) 23.5 14.5 14.5 12.5 12.5 ( ): Dimension of the D-M9AV D-A7/A80 D-A73C/A80C D-A79W D-F7/J79 D-F7W/J79W D-F79F/F7BA Auto switch Auto switch Hs Hs Hs Hs A B A B D-A7H/A80H D-F7V/F7WV D-F7BAV D-J79C Auto switch Auto switch B A A B 10 Auto Switch Mounting Series CJ2Y Auto Switch Proper Mounting

D-A59W D-Z7/Z80 D-M9/M9W D-M9A Bore size (mm) Bore size (mm) D-Z7/Z80 D-A5/A6 A B A B A B A B A B A B Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs 40 50 63 80 100 40 50 63 80 100 11.5 8.5 8 5 13 10 5 2 27 28.5 27 34 35.5 28.5 29 27 13 8 9.5 4.5 14.5 9.5 6.5 1.5 33 33.5 33 38.5 39.5 34.5 33 33 4.5 0 8.5 3.5 47.5 38.5 14.5 9.5 11 6 16 11 8 3 38.5 38 38.5 43.5 45 38.5 28 37 8.5 3.5 12.5 7.5 54

L r b a = K + mL2 K: The moment of inertia around the center of gravity of the load K = m r2 12 a2 + b2 = m In case of 4. Round plate 2 4. Round plate (Including column) Position of rotational axis: Passing through the center axis 9. Gear transmission (A) (B) No. of teeth = a 1. Find the moment of inertia B for the rotation of shaft (B). 2.

Next, B is entered to find A the inertial moment for the rotation of shaft (A) as 5 b a A = ( ) 2 B Number of teeth = b Kinetic Energy/Rotation Time Even in cases where the torque required for rotation of the load is small, damage to internal parts may result from the inertial force of the load.

6 6.5 10.5 13.5 16.5 19.5 B 12.5 15.5 18.5 21.5 A 29 29.5 33 24 28.5 29 B 6.5 7 11 14 17 20 A 26 26.5 30 21 25.5 26 B 3.5 4 8 11 14 17 A 19.5 24 24.5 B 9.5 12.5 15.5 A 31.5 22.5 27 27.5 B 9.5 12.5 15.5 18.5 A 35.5 26.5 31 31.5 B 13.5 16.5 19.5 22.5 MK220 MK225 MK232 MK240 MK250 MK263 Auto Switch Mounting Bracket Part No.

11.5 18.5 23 B 12.5 14.5 13.5 19 B 9 11 10 15.5 B 7 9 8 13.5 A 14 12 19 23.5 B 13 15 14 19.5 A 14.5 12.5 19.5 24 B 13.5 15.5 14.5 20 B 7.5 9.5 8.5 14 B 10.5 12.5 11.5 17 B 7 9 8 13.5 20 25 32 40 Note) When setting an auto switch, be sure to check its operation before adjusting.

7 7 8 B 6 6 7 B 3 3 4 0 to 1 A B 20 25 32 D-Z7/Z80 D-Y59/Y69/Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL A 23 23 32 37 Bore size (mm) B 0 0 0 4 40 50 63 80 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Minimum Stroke for Mounting Operating Range Bore size (mm) Bore size (mm) Auto

A B A B A B C D Normally closed (NC = b contact), solid state switch (D-F9G/F9H type) are also available.

B (Mounting groove no.) C (Mounting groove no.)

Insert the switch into the switch case, and install switch holder B into the first groove (MRHQ20/25) or the second groove (MRHQ10/16) and secure the switch.

MDHR2-10,15 1122MDHR2-20,30 1122H H L L When auto switch D-M9N, D-M9P, D-M9B is used When auto switch D-M9NV, D-M9PV, D-M9BV is used When auto switch D-M9NV, D-M9PV, D-M9BV is used (mm) Max. protrusion of auto switch from edge of body: H Max. protrusion of auto switch from edge of body: L, H (mm) Auto switch model Auto switch model D-M9V Air gripper model D-M9V D-M9 6.8 6.8 MDHR2-20 MDHR2

8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4.

W A A A B (mm) D-A9V D-A9 D-M9 D-M9W D-M9V D-M9WV A B A B Bore size (mm) W Hs A B W A B Hs 32 40 50 63 12 [17] 9 1 12 [17] 9 29 8 [13] 5 3 (0.5) 8 [13] 5 27 16 11.5 1.5 16 11.5 32.5 12 7.5 5.5 (3) 12 7.5 30.5 14 <19> 14.5 4.5 14 <19> 14.5 42 10 <15> 10.5 8.5 (6) 10 <15> 10.5 36.5 16.5 17.5 7.5 16.5 17.5 42 12.5 13.5 11.5 (9) 12.5 13.5 40 [ ]: Values for 5 mm stroke with 32 < >: Values for

Proper Auto Switch Mounting Position (Detection at stroke end) C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Series MY2C Series MY2H Series MY2HT (mm) D-M9, D-M9V (mm) D-M9, D-M9V (mm) D-M9, D-M9V A A A B B B Bore size 16 25 40 Operating range Bore size

, D-M9NV, D-M9PV, D-F9WV (mm) B E B Stroke Model Stroke A 100 75 50 30 20 10 100 75 50 30 20 10 MXF8 13.5 6 1 6 14 9 14 MXF12 16 25.1 9.1 9.1 33.1 17.1 17.1 MXF16 21.2 42.3 21.8 11.8 50.8 29.8 19.8 MXF20 23.4 66.7 42.2 18.7 16.7 74.7 50.2 26.7 24.7 ( ): Denotes the values of D-A93.

Magnet: D (Built-in Magnet), Bore Size: 10mm, Stroke: 5mm, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, 0.5m

Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07 to 1, Specification: Built-in magnet, Body Options: Standard (rod-end female thread), Auto Switches: M9BV

: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9BV

Magnet: Built-in Magnet, Bore Size: 10mm, Stroke: 5mm, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, 0.5m, Lead Wire or Prewired Connector: -