Standard stroke 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 How to Order Mounting Bore Stroke Suffix XB6 NCA1 Ex: NCA1B 150-0400-XB6 High temperature Auto switch capable not available Low Temperature Specifications 1.5 2 2.5 3.25 4 Bore size (inch) Air 250 psi (1.75 MPa) 8 psi (0.06 MPa) Fluid
Anodized Rod cover Aluminum alloy 1 1 PS NCA 500 2 Electroless nickel plating Cushion valve Rolled steel 2 3 Phosphate coated Snap ring Spring steel 2 Special options Nil XB5 XB6 XB7 XB5B6 XB5B7 Bore 500 600 800 4 Cushion valve seal NBR 2 Standard Oversized rod High temperature Low temperature Oversized W/ high temperature Oversized W/ low temperature Anodized Head cover Aluminum alloy 1
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing p, Compact Cylinder, CQ2, COMPACT CYLINDER, 489, 64.5 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing p, Compact Cylinder, CQ2, COMPACT CYLINDER, 489, 37.2 lb
NCM -XA Change of rod end shape Minimum Stroke for Auto Switch Mounting Heat resistant cylinder (150C) -XB6 Standard Stroke NCA -XB7 Cold resistant cylinder -XB9 Low speed cylinder (10 to 50 mm/s) Maximum manufacturable stroke (mm) No. of auto switches mounted Standard stroke(1) (mm) Long stroke (mm) Bore size (mm) Model 2 D-XB13 Low speed cylinder (5 to 50 mm/s) 1 -XC4 With heavy duty scraper
Made to order options (see Page 55) Low temperatureresistant (XB6) resistant Modification of rod end auto switch Page P 8 P 1 7 P32 fechnical Data Auto switch guide P 4 6 P 3 8 ?
Stainless Steel Body for Low Breakway Friction Double Roc/Double End Mounting 6 Available Mounting Options Non-Rotating Option Auto Switch Capable Air Cylinder: Standard Type Series:NCM Series NCM How Toordcr NC DMrB075-02 00 C S J 851 xB6 T r I Lo**" Auto-Switch Capable I xB6 -High Temp. I XB7 -Low Temp.
Made to order options (see Page 55) Low temperatureresistant (XB6) resistant Modification of rod end auto switch Page P 8 P 1 7 P32 fechnical Data Auto switch guide P 4 6 P 3 8 ?
Silrc" lrcyrinder -NCM seies Stainless Steel Cylinders Stainless Steel Body for Low Breakway Friction Double Rod/Double End Mounting 6 Available Mounting Options Non-Rotating Option Auto Switch Capable Air Cylinder: Standard Type Series:NCM Series NCM How Toordcr NC DMrB075-02 00 C S J 851 xB6 T r I Lo**" Auto-Switch Capable I xB6 -High Temp. I XB7 -Low Temp.
Magnet: None, Mounting: Both Ends Tapped, Type: Pneumatic, Bore Size: 12mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke 1: 5mm, +: None, Stroke 2: None, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None
Magnet: -, Mounting: -, Type: -, Bore Size: -, Port Thread: -, Stroke 1: -, +: -, Stroke 2: -, Body Option: -, Auto Switch Groove: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Stroke Options: -
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Without built-in
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Without built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Without built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Without built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Without built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Without built-in magnet, Support