Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing September, 1999 D-SMC.L.A. P-80 (D)
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
T NPTF Coil rated Electrical entry 3 8 G F 1 100 VAC, 50/60 Hz Grommet Nil T Conduit terminal Standard 4 1 2 Option 2 200 VAC, 50/60 Hz Port size Manual override P None Nil Option WTB Dripproof conduit terminal 3 110 VAC, 50/60 Hz 1 4 Rc 3 8 Rc 1 2 Rc 3 4 Rc 02 03 04 06 TZ Conduit terminal w/ surge voltage suppressor 4 220 VAC, 50/60 Hz How to Calculate the Flow Rate 5 24 VDC 9 Other TL
Size (port size) For Air Series variations Flow rate Remote type Output specifications Port size (Rc, NPT, G) Integrated measurement Analog output Accumulated display type Switch output pulse output 1/8 1/4 3/8 1/2 11/2 1 2 Display unit Sensor unit range l/min PFA510 550 511 521 551 PFA710 750 711 721 751 703H 706H 712H P P P 1 to 10 PFA30m P P P 5 to 50 P P P 10 to 100 31m P P P 20 to 200
1/8 Relief type Vacuum suction type 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 25, 50, 75, 100, 125, 150, 200 Available Available (40 to 63) 20 25 32 40 50 63 80 100 100 Non-lube Double acting, Available double rod 1/8 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 Suction flow rate of vacuum suction type (Reference values) Specifications Bore size (mm) Item 20/25/32/40/50
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
Heating capacity [W] 600 600 Heating capacity [W] 40 40 32 32 25 25 400 400 5 5 200 200 0 0 0 10 20 30 40 0 10 20 30 40 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9-12 Heating capacity (HRR012-A/W-20,HRR018-A/W-20) 9.5.3 HRR024-A/W-20,HRR030-A/W-20 Ambient temp. 800 800 or Ambient temp.
Ambient temp. 500 Heating capacity [W] Heating capacity [W] 400 40 40 400 32 32 300 300 25 25 5 5 200 200 100 100 0 0 10 15 20 25 30 35 40 10 15 20 25 30 35 40 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9-11 Heating capacity (HRR010-A-20-) 9.5.4 HRR010-W-20400 400 Facility water temp.
8 210.5 200 187 12 2 160.5 150 134.5 13 3 173 162.5 145 14 4 185.5 175 155.5 15 5 198 187.5 166 16 6 210.5 200 176.5 17 7 210.5 200 187 12 8 223 212.5 197.5 13 L1 L2 L3 L4 L1 L2 L3 L4 L n 9 223 212.5 197.5 13 L n 9 235.5 225 208 14 10 235.5 225 208 14 11 248 237.5 218.5 15 12 260.5 250 229 16 13 273 262.5 239.5 17 14 285.5 275 250 18 15 285.5 275 260.5 12.5 16 298 287.5 271 13.5 10 248 237.5
L* N x 4 N x 8 N x 12 N x 6 N x 12 N x 18 N x 8 N x 16 N x 10 N x 20 N x 12 N x 24 D 18 28 28 24 37 37 31 42 52 52 67 67 TCU0425-1N-X6 TCU0425-2N-X6 TCU0425-3-N-X6 TCU0604-1-N-X6 TCU0604-2-N-X6 TCU0604-3-N-X6 TCU0805-1-N-X6 TCU0805-2-N-X6 TCU1065-1-N-X6 TCU1065-2-N-X6 TCU1208 -1-N-X6 TCU1208 -2-N-X6 LX5.9 + 200 LX4.4 + 200 LX2.9 + 200 LX5.3 + 200 LX3.8 + 200 LX2.5 + 200 LX5.2 + 200 LX3 +
SO-04 SO-05 NT-02 NT-03 NT-04 AC-NI-50 8 8 9 11 30 36.9 43.9 47.3 26 32 38 41 5 6 8 10 12.5 16.5 21.0 23 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 20 25 32 40 15.0 19.6 25.4 27.7 20 25 32 40 M22 x 1.5 M24 x 1.5 M30 x 1.5 M33 x 2.0 26 32 38 41 13 17 22 24 10 Series CHN Accessory Brackets (Optional) I-shaped single knuckle joint Bracket for clevis type Material: Cast iron 20: I-02 25: I-03
Basic setting mode Main menu Alarm display menu Maintenance notif Power supply ON Circulating fluid outlet temperature Circulating fluid set temperature 200 ALm mANT 200 XXALM MENU MENU MENU / / / M no (N M circulating fluid return temp AL01 mT01 212 Alarm number (Alarm number minimum RET TEMP / / / M n mT02 AL02 014 Alarm number Circulating fluid outlet pressure PRESS / 79 Circulating fluid
5 1 10 20 30 40 50 100 200 300 400 1 5 4 10 20 30 40 50 100 200 300 400 5 10 50 100 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) l = 300mm Graph 4 l = 200mm Graph 3 v = 150mm/s or less Graph 7 v = 200mm/s or less Graph 8 20 300 300 200 200 MGF100 MGF100 20 100 100 MGF100 10 50 40 50 40 MGF63 MGF100 MGF63 Load weight m0 (kg) Load weight m0 (kg) Load
(Example) SS3YJ5-20-03 . 1 set (manifold base) SYJ512-5LZ-M5 . 2 sets (valve) SYJ500-10-1A . 1 set (blanking plate assembly) SS3YJ5-41R-03-C6 . 1 set (manifold base) SYJ514R-5G . 2 sets (valve) SYJ500-10-3A . 1 set (blanking plate assembly) The asterisk denotes the symbol for assembly.
Example: SS5YJ3-20-03 1 set (Manifold base) SYJ3120-5G-M3 2 sets (Valve) SYJ3000-21-1A 1 set (Blanking plate assembly) SS5YJ3-S41-03-C4 1 set (Manifold base) SYJ3140-5LZ 2 sets (Valve) SYJ3000-21-2A 1 set (Balnking plate assembly) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
N.O. 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz Note) N.O. valve operates properly only when appropriate pressure is applied to the pilot.
Max. 2s 2s 1s 1s Min. 0.5s 0.5s 0.2s 0.2s 0.1s 0.1s 0.05s 0.05s 0.02s 0.02s 0.01s 0.01s 6000 100 125 200 300 400 500 700 1000 1500 2000 30004000 10 100 125 200 300 400 500 600700 1000 1500 2000 3000 4000 600 5000 7000 Current (% for breaker capacity) Current (% for breaker capacity) For HRS100-A/W-20-B For HRS150-A/W-20-B HRS100-A/W-40, HRS150-A/W-40 4h 2h 1h 30min 20min 14min 10min 6min
, 250, 300 71.5 177 27 16 52 57 M14 x 1.5 5 14 136 24 100, 125, 150, 175, 200, 250, 300, 400, 500 85.5 200, 300, 500 193 32 20 64 71 M18 x 1.5 7 18 144 22.5 98.5 200, 300, 500 194 32 20 77 84 M18 x 1.5 7 18 145 21 P M N O T X Z L Q Bore size (mm) 32 40 50 63 41 34 5.5 M6 x 1 Rc(PT) 1/8 57.5 30 14 56 41 40 5.5 M6 x 1 Rc(PT) 1/8 64.5 30 14 62 49 50 6.6 M8 x 1.25 Rc(PT) 1/4 76.5 35 19 61.5
vacuum/low pressure T VQ Port size (IN, OUT port) Conduit terminal with indicator light TS Conduit terminal with surge voltage suppressor TZ Conduit terminal with light/surge voltage suppressor DL DIN terminal with indicator light DS DIN terminal with surge voltage suppressor DZ DIN terminal with light/surge voltage suppressor VKF Port size Rc (Nominal size) VP3145 VP3165 VP3185 Symbol 03