The switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 2. Mount switches in locations where there is no vibration greater than 98m/s2, or impact greater than 490m/s2. 3. Do not use in an area where surges are generated.
Never use in an atmosphere of explosive gases. The construction of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated.
(mm) With auto switch Without auto switch Bore size (mm) Stroke range (mm) A BP C D E F G H I J K L M N O OA OB P Q RA RB S T U V Z B A B 82 36 Rc 1/8 10 to 50 15.6 depth 12 14 depth 10.5 Rc 1/4 92 46 63 15 20 77 10.5 38 M10 x 1.5 103 7 17 8 60 9 M8 x 1.25 53 16 4.2 93 1.6 47.5 16.5 19 92 46 75, 100 96.5 43.5 10 to 50 19.6 depth 15.5 17.5 depth 13.5 Rc 3/8 Rc 1/8 106.5 53.5 80 21 25 98 12.5
Use an auxiliary pipe or the like and apply force evenly when tightening the hexagon socket head cap screws on the cover and case.
Basic (B): CG1WB 1011With rubber bumper 2 x M5 x 0.8 Relief port F GA F GA Port on rod end Port on rod end Width across flats KA 2 2 Width across flats KA RA RA 2 x Rc P 1 1 0 E0.05 MM H1 H1 MM D D I 0 E0.05 C R0.4 R0.4 ZZ + 2 Stroke S + Stroke H A AL Width across flats B1 Width across flats B1 H + Stroke A AL K K 8 x J NA C Female rod end effective depth A1 MM ZZ + 2 Stroke H + Stroke H
R-12F-12F 22 12 12 46 63 31.5 31.5 21.5 4 67 14 21.8 21.8 17.5 3.2 Applicable tubing O.
16 17 VHK-B1A 44.5 14.5 1 27 22 16.5 26 VHKl-08F-08F 26.2 18.7 9.7 VHKl-10F-08F 22 10 8 10 46 58.5 61 30.5 28 21.5 4 20.8 18.7 14 13.7 3.2 28 29 VHK-B2A 49 17 1 30 25 21.5 31 VHKl-10F-10F 30.5 20.8 16.1 VHKl-12F-10F 22 12 10 12 46 62 63 31.5 30.5 21.5 4 21.8 20.8 14 17 3.2 31 32 VHK-B2A 49 17 1 30 25 21.5 31 VHKl-12F-12F 31.5 21.8 17.5 3 port valve 1(P): Male thread, 2(A): One-touch fitting
U side Individual EXH spacer SSQ1000-R-3Special wiring specifications (-K) Back pressure check valve (-B) SSQ1000-BP Built-in silencer (-S) P. 2-3-49 P. 2-3-45 P. 2-3-46 P. 2-3-47 C6 L6 D-sub connector Terminal no.
solid state auto switch is available after receiving an order. 18
The operating load is an induction load. 2. The length of wiring to the load is 5m or more. 3. The load voltage is 100VAC. A contact protection box should be used in any of the above situations. Otherwise, the life of the contacts may be reduced. (They may stay on continuously.)
Rod end thread type is an optional product. (Refer to page 281).
Install an emergency stop circuit. Install an emergency stop outside of the enclosure so that the system operation can be stopped immediately and the power supply disconnected. 4.
When the hydraulic pressure of an air-hydro unit must be raised. 7. When the pressure must be raised in an explosion-proof environment. 8.
Install an after-cooler, air dryer or water separator, etc. Air that contains excessive drainage can cause malfunction of valves and other pneumatic equipment. To prevent this, install an after-cooler, air dryer or water separator, etc. 3. Use the product within the range of specifications for fluid and ambient temperature.
rod Double acting, Single rod, Non-rotating Nil W K Auto switch Nil Without auto switch (Built-in magnet) Mounting style Refer to the table below for auto switch symbol.
Refer to p.0-39 to 0-46 for Safety Instructions and common precautions. MX MXU Precautions on Handling Warning Mounting/Adjustment Caution MXS MXQ q Do not scratch or gouge the sliding portion of the guide rod by striking it with an object or getting an object trapped in it.
Use the spanner corresponding to the size of hexagonal portion, or hexagonal portion may be deformed. eTightening the thread portion of an M3, M5 or M6 fittings 1) M3 First, tighten it by hand, then give it an additional 1/4 turn with a wrench. 2) M5/M6 First, tighten it by hand, then give it an additional 1/6 turn with a wrench.
Refer to p.0-44 to 0-46 for common precautions of auto switch.