Cooling Capacity: 38 kW, Cooling Method: Air-cooled Refrigeration, Pipe Thread: NPT, with Rc-NPT Conversion Fitting, Power Supply: 50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC, Option: w/Fluid Fill Port

Cooling Capacity: 38 kW, Cooling Method: Air-cooled Refrigeration, Pipe Thread: NPT, with Rc-NPT Conversion Fitting, Power Supply: 50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC, Option: Applicable to Deionized Water Piping

Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+K+M

Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+D+K+M

Do not use in an atmosphere containing an inflammable gas or explosive gas. Use in such an atmosphere is likely to cause a fire or explosion. This system is not explosion-proof. Caution 1. Select the proper type of enclosure according to the environment of operation.

An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. 11 Series VCW 2 Port Solenoid Valve for Fluid Control/Precautions 1 Be sure to read before handling. Precautions on Design Selection Warning Warning 1. Cannot be used as an emergency shutoff valve, etc.

Be careful to the supply pressure and kinetic energy when performing an intermediate stop. Fine end stroke adjustment is considered as an intermediate stop, so the considerations for an intermediate stop must be observed when making any fine adjustments. When stopping the external slider in an intermediate position with an external stopper.

(Except C kit) F, P, T and S kits are provided with an exhaust on one side, while C kits are with an exhaust on both sides. The number of max. stations differs from kit to kit. (Refer to the table below.)

How to Order Type 46 (5 Port/Base mounted) Applicable solenoid valve SYJ340SYJ343SS5YJ3 46 05 M5 Type 46 Type S46 ( ) Single solenoid coil is on same side as the A, B port. M5 x 0.8 R1 R2 port Applicable blanking plate assembly SYJ3000-21-2A Stations Valve mounting direction 02 2 stations Single solenoid coil is on opposite side as the A, B port.

(33) 42 (35) 48 (35) 44 (37) 47 (34) 43 (36) ZPY40 49 (35) 50 (37) 49 (35) 44 (38) 46 (38) ZPY50 ( ): Figures for female thread connections.

Spatter cover Spatter cover Plug Prevention of tube releasing unconformity due to an inside intrusion or adhesion of the spatter. Prevention of tube releasing unconformity due to an inside intrusion or adhesion of the spatter. P. 5 KR P. 5 KRC1 KRP P. 5 Use to plug unused One-touch fittings.

46 LB 27 31 36 46 46 LA 35.5 41 47 62 62 LA 35 41 46 62 62 L 52.5 59 67 81 84 L 52.5 59 67 81 84 ZZ 115.5 127 137 171 175 Model MU25 MU32 MU40 MU50 MU63 Model MU25 MU32 MU40 MU50 MU63 Applicable pin 8 10 10 14 14 9 11 13 16 16 8 10 10 14 14 9 11 13 16 16 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.2

46 LB 27 31 36 46 46 LA 35.5 41 47 62 62 LA 35 41 46 62 62 L 52.5 59 67 81 84 L 52.5 59 67 81 84 ZZ 115.5 127 137 171 175 Model MU25 MU32 MU40 MU50 MU63 Model MU25 MU32 MU40 MU50 MU63 Applicable pin 8 10 10 14 14 9 11 13 16 16 8 10 10 14 14 9 11 13 16 16 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.2

60 99 16 20.5 138 142 47.5 33.5 50 Rc 3/8, 1/2, NPT 3/8, 1/2 M8 x 1.25 30 36 55 44 11 10 75.5 77 4 20 37 3.5 27 Rc 1/4, NPT 1/4 36 47 80 56 15 19 109.5 111.5 7.5 34 46 5.5 37 Rc 3/8, NPT 3/8 PPS 46 60 99.5 68 22 20.5 138.5 142.5 8 42 57 5.5 50 Rc 1/2, NPT 1/2 30 36 58.5 44 14.5 10 79 80.5 4 20 37 3.5 27 Rc 1/4, NPT 1/4 36 47 84 56 19 19 113.5 115.5 7.5 34 46 5.5 37 Rc 3/8, NPT 3/8

/Flange Rod end width across flats 10 10 21 21 46 46 Data Part no.

Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause the malfunction of pneumatic equipment, such as valves.

CD-MU02 Z 142.5 159 171 205.5 LX RR 8.5 10 11 16 LD LU 11 14 15 20 LC 16 18 20 28 Z LB 27 31 36 46 LB 27 31 36 46 LX RR 8 10 10 16 LA 35.5 41 47 62 ZZ 151 169 182 221.5 L 52.5 59 67 81 LA 35 41 46 62 LD LU 13 14 17 23 ZZ L 52.5 59 67 81 Model MLU25 MLU32 MLU40 MLU50 Model MLU25 MLU32 MLU40 MLU50 +0.4 +0.2 +0.4 +0.2 +0.4 +0.2 +0.4 +0.2 The L, Z and ZZ dimensions are reference dimensions when

odd number, an even number that is one larger than this odd number is used for the calculation.

(D) 2n x 1/4 Applicable cable O.D. 6 to 12 L Dimension n: Stations Stations Formula L1 = 46 x n + 29 L2 = 46 x n + 14 2 121 106 3 167 152 4 213 198 5 259 244 6 305 290 7 351 336 8 397 382 9 443 428 10 489 474 L L1 L2 Precautions Be sure to read this before handling the products.

14.2 21 (22) AS23l1FG-02-10(S)A 10 15.9 20.9 38.1 (38.2) 24.7 47.3 15.6 23 (23) AS33l1FG-02-06(S)A 6 8.2 16.5 29.9 (30) 17.5 40.1 AQ 1/4 17 (17.5) 12.9 13 ASV 13.3 42 (42) AS33l1FG-02-08(S)A 8 13.2 37.1 23.5 59.9 14.2 43 (43) AS33l1FG-02-10(S)A 10 15.9 17.4 23 41.2 26.1 62.5 15.6 46 (46) AS33l1FG-02-12(S)A 12 18.5 42.5 28.3 64.7 17 48 (48) AS33l1FG-03-06(S)A 6 11.2 12.9 16.6 20.2 36 21.4