SMC Corporation of America
Elite Part Number Search
Search Results "HRSH100-AN-20-AS"

600 18 1/4 18 102 M10 x 1.5 depth 16 27 11 35 38 72 32 20 20 32 2 14 63 M18 x 1.5 7 69 Up to 600 18 1/4 18 102 Note) Dimensions are the same as CG1W standard type.

Holding of pressure (including vacuum) Since valves are subject to air leakage, they cannot be used for applications such as holding pressure (including vacuum) in a pressure vessel. 6. Not for use as an emergency shutoff valve None of the valves featured in this catalog is designed for safety applications such as an emergency shutoff valve.

Standard Stroke (mm) Manufacturable stroke range Model Standard strokes CXSJ6 CXSJ10 CXSJ15 CXSJ20, 25, 32 60 to 100 10, 20, 30, 40, 50 80 to 150 10, 20, 30, 40, 50, 75 110 to 150 10, 20, 30, 40, 50, 75, 100 110 to 200 Strokes beyond the standard stroke range are available as a special order.

In case of high piston speed, the operating time of the load can be extended by using an auto switch (D-F7NT) with built-in OFF delay timer (approx. 200ms). 4. Keep wiring as short as possible. As the length of the wiring to a load gets longer, the rush current at switching ON becomes greater, and this may shorten the products life.

The maximum number of stations is 20 in terms of manifold bases, as well as solenoids. (Please consult with SMC for more stations.)

OK OK Model determination Note 1) Stroke adjustment with either a bumper bolt or adjustment bolt is considered as an intermediate stop. Note 2) When an intermediate stop is performed with an external stopper, consider the dynamic load as shown below.

40 HRS090 Standard type 0.5 5 to 35 Indoor use (400 V as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 HRSH090 Inverter type 0.1 5 to 40 Indoor use (400 V as standard, 200 V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 (400 V as standard, 200 V as an option) (Only 200 V as an option)

When designing an application, be sure to allow sufficient space for maintenance and inspection. In cases of high piston speed, the use of an auto switch (DF5NT/F7NT/G5NT and M5T) with a built-in OFF delay timer ( 200 ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.

As a result, the inside of the bowl G, is shut off from the outside air. Therefore, even if there is an accumulation of condensate in the bowl G, it will not drain out.

Keep wiring as short as possible. Although wire length should not affect switch function, use wiring 100m or shorter. 5. Take precautions for the internal voltage drop of the switch. When designing an application, be sure to allow sufficient clearance for maintenance and inspections.

Do not use in an environment where the product is directly exposed to liquid, such as cutting oils. If cutting oil, coolant, or oil mist adheres to the product, failure or increased sliding resistance can result. 3. Install a protective cover when the product is used in an environment directly exposed to foreign matters, such as dust, cutting chips, and spatter.

11 2-M6 thread depth 11 15 15 35 18 15 2-M6 thread depth 11 2-M6 thread depth 11 20 20 A 17 17 40 A 20 20 15 45 60 25 45 60 A Applicable clamp cylinder A Applicable clamp cylinder Part no.

Remove the covers as shown in Figure (2) and make further adjustment by loosening the hexagon nut. 3. Various dimensions are indicated in Table (1). Never make an adjustment that exceeds the dimensions in the table, as it may cause an accident and/or damage.

As a result, the inside of the bowl q, is shut off from the outside air. Therefore, even if there is an accumulation of condensate in the bowl q, it will not drain out.

Do not use in an environment where the product is directly exposed to liquid, such as cutting oils. If cutting oil, coolant, or oil mist adheres to the product, failure or increased sliding resistance can result. 3. Install a protective cover when the product is used in an environment directly exposed to foreign matters, such as dust, cutting chips, and spatter.