Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (ZS-46-B)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: B [Panel Mount Adapter, (ZS-46-B)], Operation Manual: -

This is a legacy product, and replaced byISE20B-T-N01-WB-X500, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, .16368 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift

Please contact us for the latest version.sales@ocaire.com, VALVE, BODY PORTED, DIN (DC), VALVE, VQZ300 VALVE, SOL 3-PORT, WB, VQZ300 BUILT IN FITTING >1/4, .35273 lb

Please contact us for the latest version.sales@ocaire.com, VALVE, BODY PORTED, DIN (DC), VALVE, VQZ300 VALVE, SOL 3-PORT, WB, VQZ300 BUILT IN FITTING >1/4, .33069 lb

Please contact us for the latest version.sales@ocaire.com, VALVE, BODY PORTED, DIN (AC), VALVE, VQZ300 VALVE, SOL 3-PORT, WB, VQZ300 BUILT IN FITTING >1/4, .20282 lb

Please contact us for the latest version.sales@ocaire.com, VALVE, BODY PORTED (DC), VALVE, VQZ300 VALVE, SOL 3-PORT, WB, VQZ300 BUILT IN FITTING >1/4, .44092 lb

Please contact us for the latest version.sales@ocaire.com, VALVE, BODY PORTED (DC), VALVE, VQZ300 VALVE, SOL 3-PORT, WB, VQZ300 BUILT IN FITTING >1/4, .98435 lb

Please contact us for the latest version.sales@ocaire.com, VALVE, BODY PORTED, DIN (DC), VALVE, VQZ300 VALVE, SOL 3-PORT, WB, VQZ300 BUILT IN FITTING >1/4, .33069 lb

Please contact us for the latest version.sales@ocaire.com, VALVE, BODY PORTED (AC), VALVE, VQZ300 VALVE, SOL 3-PORT, WB, VQZ300 BUILT IN FITTING >1/4, .25300 lb

Please contact us for the latest version.sales@ocaire.com, VALVE, BODY PORTED, DIN (AC), VALVE, VQZ300 VALVE, SOL 3-PORT, WB, VQZ300 BUILT IN FITTING >1/4, .25300 lb

This is a legacy product, and replaced byZSE20CF-R-M-N02-WB-X502, SWITCH ASSEMBLY, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, KD, ZSE40/50/60 1/4 PORTED, .28660 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift inputDisplayDisplay