m P 0.1 x m + m P D 1.6 x D 5.0 x D 5.0 x m m mv P Pv m > mv P > Pv Determination of allowable load mass & pressure Inclined operation (Refer to page 8-16-8
m P 0.1 x m + m P D 1.6 x D 5.0 x D 5.0 x m m mv P Pv m > mv P > Pv Determination of allowable load mass & pressure Inclined operation (Refer to page 8-16-8
L Rubber stopper screw Switch rail Mounting tap L Stud fastening: After a temporary tightening, tighten an additional 1/4 turn. Metal stopper screw L Shock absorber 8-9-16
Operating range Cylinder model C D 8 8 8 8 Mounting bolt size M3 x 50 L M3 x 60 L M3 x 50 L M3 x 60 L M5 x 75 L M5 x 85 L M5 x 75 L M5 x 85 L M5 x 85 L M5 x 95 L M5 x 75 L M5 x 85 L M6 x 95 L M6 x 130 L M8 x 100 L M8 x 130 L 50 60 50 60 75 85 75 85 85 95 75 85 95 130 100 130 MKB12-10 MKB12-20 MKB16-10 MKB16-20 MKB20-10 MKB20-20 MKB25-10 MKB25-20 MKB32-10 MKB32-20 MKB40-10 MKB40-20 MKB50-20
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (ZS-46-B)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)], Operation Manual
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)],
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)], Operation Manual
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (ZS-46-B)], Operation Manual: K (Operation
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (ZS-46-B)], Operation Manual: Y (w/o
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)