Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: NPT1/8, Lead Wire: w/o Lead Wire, Bracket: B [Panel Mount Adapter, (ZS-46-B)], Operation Manual: -
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: None, Operation Manual: w/o Operation Manual, w/o Calibration Certificate
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual: Operation Manual, Calibration Certificate
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)], Operation Manual: w/o Operation Manual, w/o Calibration Certificate
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: B [Panel Mount Adapter, (ZS-46-B)], Operation Manual: -
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: NPT1/8, Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: w/o Operation Manual, Calibration Certificate
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: NPT1/8, Lead Wire: w/o Lead Wire, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)], Operation Manual: -
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type), Bracket: A5 [Bracket E for M12 Connector Type (ZS-46-A5)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration Certificate)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type), Bracket: A4 [Bracket D for M12 Connector Type (ZS-46-A4)]
Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: D (Panel Mount Adapter + Front Protection Cover)
.: ZS-46-D) psi P ZSE20A(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger".
.: ZS-46-D) Hysteresis "Nil" or M kPa ZSE20(F) : Arbitrary display These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger".
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type), Bracket: A4 [Bracket D for M12 Connector Type (ZS-46-A4)]
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 connector type), Bracket: A4 (Bracket D for M12 Connector Type)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: D (Panel Mount Adapter + Front Protection Cover)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: D (Panel Mount Adapter + Front Protection Cover), Operation Manual: K (Operation Manual, Calibration Certificate)