Auto switch u The detection position can be changed under the conditions in step t.
95.5 24.5 115.5 44.5 115.5 MX D-M9, D-M9V (mm) Mounting pattern q Bore size Mounting patternq A1 Mounting patternw A2 Mounting patterne A3 MTS Operating range B1 A1 B1 B2 B3 (mm) 10 15 25 5.5 34 64 22 76 34 76 MY 5 35 70 23 82 35 82 5 40.5 99.5 28.5 111.5 40.5 111.5 CY Mounting pattern w B2 A2 D-F9W, D-F9WV MG (mm) Bore size Mounting patternq A1 Mounting patternw A2 Mounting patterne A3
30 30 30 30 H1 W H1 DA E DA W Symbol: A9 Symbol: A10 Symbol: A11 Symbol: A12 X C0.5 R sphere T T C1 C0.5 file chamfer C WA DA F L X L R sphere F X X L R sphere TP H1 L T W1 L T L W1 L L 6-17-10 6-17-11 10 Simple Specials -XA1 to XA38: Change of Rod End Shape These changes are dealt with Simple Specials System.
Or, supply pressure is below the minimum set (differential) pressure or lower limit of the display pressure. t (ms) t (ms) Time
Options 15.1 I/O cable 1) How to Order the I/O cable (2) Parallel I/O cable connector terminals L A T H LATH2LATH5Terminal Insulator Insulator number color Dot Dot color color A1 Red Light Red * Cable length [L] brown A2 Grey Black A3 Grey Yellow Red 1 1 m A4 Grey Black 3 3 m A5 Green Light Red green A6 Grey Black 5 5 m A7 Grey Grey Red A8 Grey Black A9 Grey White Red A10 Green Black I/O
A C B Applicable model Dimensions [mm] A B C HECR002-A5-E 14 230 35 HECR004-A5-E 45 HECR006-A5-E HECR008-A5-E 44 HECR010-A2-E HECR008-W5-E 46 HECR012-W2-E 310 13 400 15 Option symbol F With Flow Switch F HECR Applicable model HECR002-A5-F HECR004-A5-F HECR006-A5-F HECR008-A5-F HECR010-A2-F HECR008-W5-F HECR012-W2-F With flow switch This is an ON/OFF switch detecting low levels of the circulating
35.0 17.8 28.5 33.8 57.1 T Rc Rc 1 2 VMG 15-2-115 Series KB 3 Other Piping Material Nipple: KBN Weight (g) D L A Model KBN1 KBN2 KBN3 KBN4 2.9 4.6 7.2 10.2 16.8 21.0 28.6 30.4 14.0 15.0 16.5 17.0 35.0 39.0 41.5 Elbow Different Diameter Female Connector Module: KBD Weight (g) 18.0 28.9 59.5 D1 D2 D3 L1 L2 L3 L4 A1 A2 Model KBD2-1 KBD3-2 KBD4-3 15.2 20.9 26.5 17.6 25.2 32.3 21.0 28.6 30.4
MXY6 MXY8 MXY12 Model A1 0.6 A2 A3 1 MXY6 MXY8 MXY12 2 580 16 15 MXY6 MXY8 MXY12 14 980 20 19 15.5 The above value represents the maximum value for each allowable load mass.
115.5 D-F9, D-F9V (mm) Mounting patternq Bore size Mounting patternq A1 Mounting patternw A2 Mounting patterne A3 B1 A1 Operating range B1 B2 B3 (mm) 10 15 25 5.5 34 64 22 76 34 76 5 35 70 23 82 35 82 5 40.5 99.5 28.5 111.5 40.5 111.5 Mounting patternw B2 A2 D-F9W, D-F9WV (mm) Bore size Mounting patternq A1 Mounting patternw A2 Mounting patterne A3 Operating range B1 B2 B3 (mm) 10 15 25
7 i e t !0 q y @2 @3 !3 @4 r !8 !6 o !1 !
Bulkhead female connector: KBE T Connectiong thread Tube O.D. Weight (g) H2 (Hex.) H1 (Hex.) D L A2 A1 M Part No.
T Attach thread Weight (g) H1 (Hex.) H2 (Hex.) A1 M A2 D L Part No.
Example) Step data of the controller setting kit [Normal mode] Speed Position Accel Decel PushingF T riggerL V PushingSp Moving F Area1 Area2 In posn No.
Shock absorber Lock plate 1191 MY1B Series Construction 25, 32, 40 MY1B25 to 40 r @3 @9 y u t !5 w @7 !1 !7 !8 !9 @0 e #7 i !6 @5 #5 q #9 #4 !3 #2 !2 @1 !0 @2 @6 #6 #3 @8 #1 @4 o #8 !
i gl m n u a m 0 nt a e M dj m us t 19 ax e im gl u an m t ad en ju m st Friction fittings Note) Can be adjusted 5 at the rotating ends.
Common EXH port Common PS/PD port Application ZZK2-A1 Yes PS = PD Ejector complex exhaust PV = PS = PD ZZK2-A1-D Yes PS PD Ejector complex exhaust PV = PS PD Ejector individual exhaust PV = PS = PD ZZK2-A2 ZZK2-P2 None PS = PD Vacuum pump system PV PS = PD Ejector individual exhaust PV = PS PD ZZK2-A2-D ZZK2-P2-D None PS PD Vacuum pump system PV PS PD When PS = PD, the common PS/PD
+b2 12 I = m a2 12 eThin rectangular plate Position of rotary axis: Parallel to side b and through the center of gravity yLoad at the end of lever arm I = m1 + m2 a22 + K a12 3 I = m a2 12 I = m2 2r 2 5 4.1-21