ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Note 1)Ambient temperature (oC) Note 1)Outlet air atmospheric pressure dew point (oC)Inlet air flow rate (L/min [ANR]) Note 2)Outlet air flow rate (L/min [ANR])Purge air flow rate (L/min [ANR]) Note 3)Inlet air temperature (oC)Inlet air saturation temperature (oC)Ambient temperature (oC)IDG30LACompressed air0.3 to 1.0 5 to 50 5 to 50 409375180.72525251 L/min [ANR] {In case of Inlet air pressure
(C) Note 1)Ambient temperature (C) Note 1)Outlet air atmospheric pressure dew point (oC)Inlet air flow rate (L/min [ANR]) Note 2)Outlet air flow rate (L/min [ANR])Purge air flow rate (L/min [ANR]) Note 3)Inlet air temperature (oC)Inlet air saturation temperature (oC)Ambient temperature (oC)IDG3Compressed air0.3 to 0.85 5 to 55 5 to 55 20312560.7252525?
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
This is a legacy product, and replaced byVFM250-N02-01S, VALVE, MECH L (STEEL), VALVE, VM BODY PT 1/4, .68200 lb
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: L (Bottom), Output Specification: 1 [Analog Output (1 to 5 V)]
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N02 (NPT1/4), Piping Entry Direction: L (Bottom), Output Specification: 1 [Analog Output (1 to 5 V)]
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N02 (NPT1/4), Piping Entry Direction: L (Bottom), Output Specification: 2 [Analog Output (4 to 20 mA)]
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: L (Bottom), Output Specification: 2 [Analog Output (4 to 20 mA)]
This is a legacy product, and replaced byAC21-N02-V-2Z-B-X2217, F/R/L COMBO UNIT EPOXY COATED, AIRLINE EQUIPMENT, AC MASS PRO, DC, AC MASS PRO 1/4 MODULAR (NPT), .00000 lb
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: E (Panel Mount Adapter), Operation Manual: K (Operation Manual, Calibration
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: A3 (Bracket C)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D.: 07 (1/4"), Port Size/Applicable Tube: N02 (1/4" Thread), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D.: 11 (3/8"), Port Size/Applicable Tube: N02 (1/4" Thread), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D.: 03 (5/32"), Port Size/Applicable Tube: N02 (1/4" Thread), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D.: 01 (1/8"), Port Size/Applicable Tube: N02 (1/4" Thread), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D.: 09 (5/16"), Port Size/Applicable Tube: N02 (1/4" Thread), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D.: 13 (1/2"), Port Size/Applicable Tube: N02 (1/4" Thread), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D.: 07 (1/4"), Port Size/Applicable Tube: N02 (1/4" Thread)