If the diaphragm is not functioning, the operating fluid may flow to the pilot air side and at the same time the operating air may flow out to the liquid circuit. This makes it impossible to restart the operation.

Note 1) Since static electricity may be generated, implement suitable countermeasures. Note 2) Use caution as permeation may occur. The permeated fluid may effect the parts of other materials. PB Compatibility is indicated for fluid temperatures of 100C or less.

Hex. across flats may be deformed, if using an improper wrench for hex. across flats.

Equipment which may generate electromagnetic interference or whose function may be compromised by electromagnetic interference is required to be immune to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission).

-r r r R < i 5 'gauge nipple siz may vary slightly Series NVFR400[:Base Mounted T]pe @ o Manifold block Parts List No. Description Matrial Parts No.

If tightened insufficiently, nut may be loosened and it may result in air leakage or may come off. 4. When using soft copper tube, first tighten the nut by hand and then give it an additional one turn with wrench. Use JIS H3300, equivalent to seamless tube C1220T -0, as soft copper tube.

Equipment which may generate electromagnetic interference or whose function may be compromised by electromagnetic interference is required to be immune to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission).

If the tightening torque is exceeded the mounting screws and brackets may damaged. If the tightening torque is insufficient, the product may be displaced and the mounting screws may come loose (Refer to page 14 "Mounting and Installation".) Do not apply excessive stress to the product when it is mounted with a panel mount.

There may be an error in the output voltage depending on this output impedance and the input impedance of customers' equipment.

If the tightening torque is exceeded the mounting screws and brackets may damaged. If the tightening torque is insufficient, the product may be displaced and the mounting screws may come loose (Refer to page 14 "Mounting and Installation".) Do not apply excessive stress to the product when it is mounted with a panel mount.

Equipment which may generate electromagnetic interference or whose function may be compromised by electromagnetic interference is required to be immune to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission).

Furthermore, since valves and cylinders are not guaranteed for zero air leakage, it may not be possible to hold a stopped position for an extended length of time. Contact SMC if it is necessary to hold a stopped position for an extended time. 3.

If using a softnylon tube, it may be shrunk and cause air leakage or the tube may be loosen out. 2. The value of the max. operating pressure is at a temperature of 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube.

Equipment which may generate electromagnetic interference or whose function may be compromised by electromagnetic interference is required to be immune to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission).

Equipment which may generate electromagnetic interference or whose function may be compromised by electromagnetic interference is required to be immune to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission).

Equipment which may generate electromagnetic interference or whose function may be compromised by electromagnetic interference is required to be immune to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission).

Equipment which may generate electromagnetic interference or whose function may be compromised by electromagnetic interference is required to be immune to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission).

When operating at low-speeds which exceed the rotation time adjustment range, use caution as it may result in sticking or malfunction.

Equipment which may generate electromagnetic interference or whose function may be compromised by electromagnetic interference is required to be immune to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission).

(variations as much as 30%) There may be large changes depending on the ambient environment. + Minimum length [mm] with bracket T Auto Switch 32 40 50 63 80 100 D-Z7/Z8, D-Y5/Y7 (W) D-Y6/Y7 (W) V D-Y7BA 80 85 90 90 95 100 60 55 85 90 65 90 70 100 75 105 85 110 Mounting and Movement of Auto Switches Caution!