Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Orifice: Orifice shipped with the Product, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])
Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE75[H]), Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: B (Bracket B), Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: B (Bracket B)
Type 31 How to Order Applicable solenoid valve Note) SY113--M3 SY113A--M3 SY123--M3 SY123A--M3 Applicable blanking plate assembly SY100-77-1A SS3Y1 31 05 Stations 02 2 stations P R 20 20 stations R port M5 x 0.8 P port M5 x 0.8 Note) SY113(A) and SY123(A) cannot be mounted on the same manifold.
= 26 x n + 12 2 76 64 3 102 90 4 128 116 5 154 142 6 180 168 7 206 194 8 232 220 9 258 246 10 284 272 L L1 L2 [ ]: With light/surge voltage suppressor 4-7-8
NARM 2500 05 A 02 G1 Optimal for central pressure control. Accessory Regulator for manifold Pressure easily set using the new handle. One-touch lock system.
List part numbers of the installed valve and option in required station location separately under manifold part number. 2.1-10 Series SY100 Common SUP/Common EXH 30 Type How to Order Applicable solenoid valve (1) SS3Y1 30 05 F SY113-l-M3 SY113A-l-M3 Stations 02 Applicable blank plate assembly 2 stations ... ...
(max. 20 stations) Valve stations Supply/Exhaust block assembly fitting specifications Note Symbol 02 Stations 2 stations Double wiring specification Straight Nil L B Supply/Exhaust block assembly mounting position 08 02 Elbow fitting (upward) 8 stations Elbow fitting (downward) 2 stations Specified wiring (up to 16 solenoids are possible) U D B M U Side (2 to 10 stations) D Side (2 to
R Right side (PV port on the right side) L Left side (PV port on the left side) 02 2 B Both sides (PV port on both sides) Nil All stations 1 Station 1 only 08 8 1 Viewed from the front side of valve unit, confirm the port location on the right and/or left side. 2 EXH ports are released to atmospheric pressure in both sides.
VE 3 Bleed port Model (Made to Order) Pressure range Note) Indication unit Connection thread VY1 Note Model MPa G43-2-01 to 02-X2 G43-4-01 to 02-X2 G43-6-01-X2 G43-7-01 to 02-X2 G43-10-01 to 02-X2 G43-2-01 to 02-X3 G43-4-01 to 02-X3 G43-6-01-X3 G43-7-01 to 02-X3 G43-10-01 to 02-X3 G43-2-01 to 02-X4 G43-4-01 to 02-X4 G43-6-01-X4 G43-7-01 to 02-X4 G43-10-01 to 02-X4 0 to 0.2 0 to 0.4 0 to 0.6
The ISE70G pressure sensors provide continuous quantitative values, as well as switched digital outputs when pressure set points are met. Compatible fluids include any non-corrosive liquid or gas. 6 pressure ranges are offered up to 50 MPa. This sensor is also IO-Link compatible.
The ISE70G pressure sensors provide continuous quantitative values, as well as switched digital outputs when pressure set points are met. Compatible fluids include any non-corrosive liquid or gas. 6 pressure ranges are offered up to 50 MPa. This sensor is also IO-Link compatible.
(mm) 04 06 08 10 12 Type 4 6 8 10 12 Port size Elbow Universal 2 3 01 02 03 04 R 1/8 R 1/4 R 3/8 R 1/2 Control type Meter-out Meter-in 0 1 With residual pressure release valve With One-touch fitting 15-9-36 2 Speed Controller with Residual Pressure Release Valve with One-touch Fitting, Elbow Type/Universal Type Needle Valve/Flow Characteristics AS2201FE-02, AS2211FE-02 AS2301FE-02, AS2311FE