ISG (21) Seal conduit entry ZSM With DIN rail L1 60 3 38 L2 38 5 Terminal block box LED level meter End plate L EXH port End plate R 0 3 0 3 3 0 P P P T T T U U U E E E L L L S S S L L L 81 6 9 6 9 6 9 0.3 0.2 0.1 0.3 0.2 0.1 0.3 0.2 0.1 0 MPa 0.4 0 MPa 0.4 0 MPa 0.4 18 12 20.5 Pressure gauge SUP port Rc, NPT, G 1/8 DIN rail mounting bracket 5.25 DIN rail center L3 11.2 L4 24 L5 OUT 3 OUT
For AC voltage valves there is no S option. It is already built-in to the rectifier circuit. With light/surge voltage suppressor (Non-polar type) DC specifications of type D and DO is only available with 12 and 24 VDC. For AC voltage valves there is no S option. It is already builtin to the rectifier circuit. For type R and U, DC voltage is only available.
T4 = 0.2 [s] Calculation example) T1 to T4 can be calculated as follows. T1 = V/a1 = 200/3000 = 0.067 [s], T3 = V/a2 = 200/3000 = 0.067 [s] 40 0.5 200 (0.067 + 0.067) 200 T2 = = = 0.133 [s] L 0.5 V (T1 + T3) V T4 = 0.2 [s] Therefore, the cycle time can be obtained as follows.
T4 = 0.2 [s] T1 = V/a1 = 200/3000 = 0.067 [s], T3 = V/a2 = 200/3000 = 0.067 [s] T2 = = = 0.133 [s] L 0.5 V (T1 + T3) V 40 0.5 200 (0.067 + 0.067) 200 T4 = 0.2 [s] Therefore, the cycle time can be obtained as follows.
MY3M Shock Absorber Specifications Piston Speed 10 16 to 100 Bore size (mm) RB 0806 RB 1007 RB 1412 RB 2015 RB 0805 Model Without stroke adjusting unit 100 to 500 mm/s 100 to 1000 mm/s 100 to 1500 mm/s (2) A unit 2.9 5.9 19.6 58.8 100 to 200 mm/s 100 to 1000 mm/s (1) Max. energy absorption (J) 1.0 Stroke adjusting unit L unit and H unit 6 7 12 15 100 to 1000 mm/s Stroke absorption (mm) 5
Non plug-in Specifications Number of solenoids Elbow fitting (Upward entry) (Metric size) L2: 2 one-touch fitting L4: 4 one-touch fitting (Inch size) LN1: 1/8" one-touch fitting LN3: 5/32" one-touch fitting Symbol 1 pc. (Single solenoid) 2 pcs. (Double solenoid) S D Rated voltage 24 VDC 12 VDC 5 6 Common Specification +COM. COM.
Valve model Type of actuation Port size 1 4/2 (P A/B) Flow characteristics Note 2) Note 3) Effective area mm2 4/2 5/3 (A/B EA/EB) Weight (g) Pilot port size Cv C [dm3/ (s bar)] b Cv C [dm3/ (s bar)] b Grommet Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center 48
Station Address MECHATROLINK-III Communication Baud Rate 100 Mpbs Transmission Cycle 125 s, 250 s, 500 s, 750 s, and 1.0 ms to 4.0 ms (increments of 0.5 ms) Number of Transmission Bytes 16, 32, or 48 bytes per station Use the DIP switch S3 to select the number of words.
Note 4) Piston speed is ranged from 50 to 500 mm/s. Standard model no.
1 Sub-plate Assembly Part No.: VZ400-S!2 Mounting bolt and gasket are not attached. Carbon steel Round head combination screw !4 !5 !6 Pilot valve assembly !
wire length) 91.7 [96.1] Approx. 300 C4 N3 For (Built-in One-touch fitting) Grommet (G) For M5 L1 L2 Manual override 4 10 2-4.5 (For mounting) 10 1/8 (P, R port) 36.5 17 12.5 54.2 [56.4] 53.4 [55.6] 78.8 [83.2] P R 31.5 3.2 31.2 P R (4.4) B B B B B 32 15.3 7.5 17 16 A A A A A SV 1 (Station n) (Station 1) L1 L2 4.5 (Pitch) P = 10.5 SZ (Light/Surge voltage suppressor) 15.5 15.5 (Station n)
For (Built-in one-touch fitting) C4 N3 4 L2 L1 For M5 Manual override 10 12.3 35 15.5 91.7 [96.1] 0.2 34.2 78.8 [83.2] 36.5 17 12.5 57.2 [59.4] P R P R A A A A A 31.5 56.4 [58.6] B B B B B (4.4) 2-4.5 (For mounting) (Pitch) P = 10.5 (Station 1) (Station n) 15.5 L1 L2 4.5 (Station 1) (Station n) 15.5 (Light/surge voltage suppressor) (Light/surge voltage suppressor) + + + + + + + + + + B B
SS5YJ3-32,S32Station -M5T Stations L1 L2 SS5YJ3-32,S32Station -N3T 3 52 44 6 83.5 75.5 8 104.5 96.5 10 125.5 117.5 20 230.5 222.5 2 41.5 33.5 4 62.5 54.5 5 73 65 7 94 86 9 115 107 11 136 128 12 146.5 138.5 13 157 149 14 167.5 159.5 15 178 170 16 188.5 180.5 17 199 191 18 209.5 201.5 19 220 212 Stations L1 L2 3 53 44 6 84.5 75.5 8 105.5 96.5 10 126.5 117.5 20 231.5 222.5 2 42.5 33.5 4 63.5
S = 6mm 5. S = 15mm 4. S = 10mm 7. S = 27mm 5. S = 15mm 7. S = 27mm 10. S = 38mm VCA21 200 300 400 500 600 700 VCA21 VCA31 VCA31 VCA41 VCA41 VCA41 Other 200 400 400 600 800 1000 1200 1.
to the control panel,s protective earth (PE).
to the control panel,s protective earth (PE).
Pressure Range: 0 to 1.6 MPa, Piping: G 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Symbol Low-speed Cylinder (5 to 50 mm/s) -XB13 Even if driving at lower speeds 5 to 50 mm/s, there would be no stick-slip phenomenon and it can run smoothly.
M1E m x g FE M3E = 1/3 x FE x L2 (FE = 1.4/100 x a x g x m) = 0.05 x a x m x L2 = 0.05 x 300 x 0.5 x 0.04 = 0.3 [Nm] 3B = M3E/M3E max = 0.3/1.07 = 0.28 Investigate M3E. a From above, find the value of M3E max at 420mm/s in Graph 3. M3 M3E m x g FE L2 From above, n = 1 + 2 + 3A + 3B = 0.1 + 0.082 + 0.35 + 0.28 = 0.812.
GDM2A-L1 GDM2A-L1 GDM2A-L2 GDM2A-L2 GDM2A-L2 GDM2A-L2 GDM2A-L5 GDM2A-L15 24 VDC 100 VAC 12 VDC 110 VAC 100 VAC 200 VAC 110 VAC 220 VAC With light 200 VAC 230 VAC With light 220 VAC 240 VAC 230 VAC 24 VAC 240 VAC 48 VAC 24 VAC 48 VAC Select an appropriate DIN connector suitable for the coil insulation type.