SMC Corporation of America
Elite Part Number Search
Search Results "ISE71-N02-AB-MS"

SWEDEN SMC Pneumatics Sweden AB SWITZERLAND SMC Pneumatik AG U.K. SMC Pneumatics (U.K.) Ltd. SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd. SOUTH KOREA SMC Pneumatics Korea Co., Ltd. TAIWAN SMC Pneumatics (Taiwan) Co., Ltd. THAILAND SMC (Thailand) Ltd. AUSTRIA SMC Pneumatik GmbH (Austria) BELGIUM SMC Pneumatics N.V./S.A.

SWEDEN SMC Pneumatics Sweden AB SWITZERLAND SMC Pneumatik AG U.K. SMC Pneumatics (U.K.) Ltd. SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd. SOUTH KOREA SMC Pneumatics Korea Co., Ltd. TAIWAN SMC Pneumatics (Taiwan) Co., Ltd. THAILAND SMC (Thailand) Ltd. NORTH AMERICA CANADA SMC Pneumatics (Canada) Ltd. MEXICO SMC Corporation (Mexico), S.A. de C.V. U.S.A.

V (mm/s) = Auto switch operation range (mm) Load operating time (ms) x 1000 In cases of high piston speed, the use of an auto switch (D-F5NT, F7NT, G5NT and M5T) with a built-in OFF delay timer (approx. 200ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.

Positioning Operation ON OFF IN Output the step data no. 15 ms or more Input DRIVE ON OFF OUT BUSY Output INP Speed Positioning operation 0 mm/s If the actuator is within the in position range of the step data, INP will be turned ON, but if not, it will remain OFF . OUT is output when DRIVE is changed from ON to OFF .

Operating current of load > Leakage current (Input OFF signal of controller) V (mm/s) = Auto switch operating range (mm) Time load applied (ms) X 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3-wire switch if this specification will not be satisfied.

block plate> Residual pressure release valve perfect spacer VVQ4000-25A-1 Note 1) SUP stop valve spacer VVQ4000-37A-1 Interface regulator ARBQ4000-00-1 A B P Throttle valve spacer VVQ4000-20A-1 PUSH LOCK Note1) Perfect spacers with residual pressure release valve cannot be combined with external pilot specifications. 4 Series VQC Plug-in Unit Base-Mounted Type Models Model Response time ms

Auto switch operating range (mm) _ Load operating time (ms) Operating current of load (OFF condition) > Leakage current V (mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3-wire switch if this specification will not be satisfied.

1/4 7/16-20 1.25 0.44* 2.88 0.50 3.25 4.00 1.38 5.32* 63 (2.50") 0.75 1/4 7/16-20 1.50 0.44* 3.00 0.50 3.75 4.50 1.38 5.39* 80 (3.25") 1.13 3/8 3/4-16 1.88 0.56* 3.25 0.75 4.75 5.75 1.88 6.41* 100 (4.00") 1.13 1/2 3/4-16 2.25 0.56* 3.25 0.75 5.50 6.50 1.88 6.48* * DENOTES DEVIATION FROM NFPA 6 S tainles s S teel Air Cylinder S eries CG5 NFPA Interchangeable E nd Lug Mounting Type CG5P (MS

.::; I ~"~ ...Ab.. ,..;= ~ -LK F N -H S + Stroke .!'!. FT ZZ1 +t+ Stroke Z Z t Stroke (mm) .. ,.,.,." .".

Auto switch operating range (mm) Load operating time (ms) x 1000 V (mm/s) = Current to operate load (OFF condition) > Leakage current 4. Keep wiring as short as possible. As the length of the wiring to a load gets longer, the rush current at switching ON becomes greater, and this may shorten the products life. (The switch will stay ON all the time.)

Auto switch operating range (mm) _ Load operating time (ms) Operating current of load (OFF condition) > Leakage current V(mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3 wire switch if this specification will not be satisfied.

V (mm/s) = Auto switch operating range (mm) Load operating time (ms) x 1000 In case of high piston speed, the operating time of the load can be extended by using an auto switch (D-F7NT) with built-in OFF delay timer (approx. 200ms). 4. Keep wiring as short as possible.

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: Operation

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: None

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: None