Pressure Range: 0 to 10 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: Orifice shipped with the Product, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: Orifice shipped with the Product, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: None

Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 10 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 10 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 10 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate

Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: None

Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: None, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate

Pressure Range: ISE77G (0 to 10 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)

(mm) 04 06 08 10 12 Type 4 6 8 10 12 Port size Elbow Universal 2 3 01 02 03 04 R 1/8 R 1/4 R 3/8 R 1/2 Control type Meter-out Meter-in 0 1 With residual pressure release valve With One-touch fitting 15-9-36 2 Speed Controller with Residual Pressure Release Valve with One-touch Fitting, Elbow Type/Universal Type Needle Valve/Flow Characteristics AS2201FE-02, AS2211FE-02 AS2301FE-02, AS2311FE

Description AXT336-1A-1 01 02 01 02 01 02 02 03 02 03 02 03 02 03 Manifold block assembly AXT336-1A-2 AXT336-1A-3 AXT336-2A-1AXT336-2A-2AXT336-3A-1AXT336-3A-2q End plate (U side) assembly w End plate (D side) assembly e Terminal assembly Junction cover assembly Tie-rod r t y Replacement Parts No. u Description Material Carbon steel NBR NBR Part no.

N L1 L2 L3 L4 L5 L6 P Q1 Q2 M KRM12-06-02-10 KRM12-06-02-6 99 10 6 6 89 47 1 4 17 19.5 33.5 23.5 33 13.5 8.5 13 19 10 125 6 108 10 55 73 106 104 KRM12-08-03-10 KRM12-08-03-6 3 8 8 19 139 11.5 22.5 37.5 26 36.5 10 15.5 20.5 14.7 86 126 119