03 04 1/8 1/4 3/8 1/2 Type of setting Regulating pressure range 0 Basic type (Handle) For 90-IR1000/2000 series 0 1 2 0.005 to 0.2 MPa 0.01 to 0.4 MPa 0.01 to 0.8 MPa For 90-IR3000 series 0.01 to 0.2 MPa 0.01 to 0.4 MPa 0.01 to 0.8 MPa 0 1 2 *Specifications and dimensions for the 90-series are the same as standard products.
The spacing of the side support must be no more than the values shown in the graphs at right. 200 200 190 190 (2100) (2100) (2100) 180 180 170 170 160 160 m 150 150 140 140 (2400) (2400) (2400) (2400) (2400) 130 130 l (1800) (1800) (1800) 120 120 Weight m (kg) Weight m (kg) 110 110 MY1MW63 MY1MW63 100 100 (2000) (2000) (2000) (2000) (2000) 90 90 (1500) (1500) (1500) MY1CW63 MY1CW63 m 80 80
2500 3000 28.5 3/8, 16 3/8, 16 3/8, 16 1/2, 16 100 =0.7 38 47 0.5 56.5 0.1 0.3 50 10, 12, 16 1/4, 3/8 500 15 63 1000 1500 2000 2500 3000 30 3/8, 16 1/2, 16 1/2, 16 3/4, 16 3/4, 16 0 45 1,000 2,000 3,000 60 Maximum speed Vmax [mm/s] 75 80 89.5 16 3/8, 1/2 500 24.5 =0.7 1000 1500 2000 2500 3000 500 1000 1500 2000 2500 3000 48.5 3/8, 16 1/2, 16 3/4 3/4 3/4 3/8 1/2, 16 3/4 3/4 3/4 3/4 150 80
For Air 1.6 1.4 Upstream pressure of valve P1 Downstream pressure P2 [MPa] 1.5 MPa 1.6 MPa 1.2 1.3 MPa 1.4 MPa Subsonic 1.0 Critical pressure 1.2 MPa 1.1 MPa 0.8 1.0 MPa 0.9 MPa 0.8 MPa Sonic 0.6 0.7 MPa 0.6 MPa 0.5 MPa 0.4 0.4 MPa 0.3 MPa 0.2 0.2 MPa 0.1 MPa 0 VXB215A D(H) 10 12000 14000 8000 2000 4000 6000 VXB215B E(H) 16000 14000 10 12000 8000 2000 4000 6000 VXB215C F(H) 10 2000 6000 8000
Low noise 60 ZK2A07 (Silencer exhaust) ZK2G07 (High-noise reduction silencer exhaust) 46 dB (A) 1 50 1 Nozzle size: 0.7 (Under SMCs measurement conditions) 40 Noise level [dB (A)] 30 Reduces high-frequency range from 2000 to 20 Hz. 20 10 0 200 2000 20 Frequency [Hz] Suction flow Improved by up to approx. 20% Max. suction flow [L/min (ANR)] Nozzle size Exhaust type 40 80 Approx. 20% High-noise
Data 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 0.2 Minimum operating pressure (MPa) 40 1500 2000 0.16 0.16 0.14 0.15 0.12 0.15 Note 1) Please contact SMC if the maximum stroke will be exceeded.
However, when exceeding a 2000 mm stroke, specify -XB11 at the end of the model number. Refer to the made to order specifications on page 8-14-24.
16, 20, 50, 63, 80, 100 16, 20, 25, 32, 40, 50, 63 16, 20, 25, 32, 40, 50, 63 16, 20 16, 25, 40 16, 25, 40 MY1B 100 to 2000 16, 20, 25, 32 25 to 200 CXWL 2001 to 5000 (3000 for 16 only, 3000 for MY1MW) MY1M (W) 100 to 2000 10 to 75 10 80, 90, 100, 110, 120, 125, 150 110, 120, 125, 150 2001 to 5000 (3000 for 16 only, 3000 for MY1CW) MY1C (W) 100 to 2000 CXSJ 10 to 100 15 MY1H MY2C MY2H/HT
Note) Except SI Unit Manifold Solenoid Valves Manifold Solenoid Valves Manifold Solenoid Valves Series SY3000/5000 Series SV1000/2000/3000 Series S0700 Series VQC1000/2000/4000 IP67 IP40 IP67 IP67 Note) The SY3000/5000, S0700, and VQC1000/2000/4000 are not UL-compatible.
DI-1 Program Description SPN (1000) STA (200) STB (300) MOV (1000) TIM (100) MOV (2000) STOP Speed (Motor speed) Acceleration time constant Deceleration time constant Absolute move command Dwell command time Absolute move command Program end 1000[r/min] 200[ms] 300[ms] 1000[10STMm] 100[ms] 2000[10STMm] a) b) c) d) e) f) b) Acceleration time constant (200ms) c) Deceleration time constant (
25 32 40 Operating temperature range (C) CC ML2B RB It is possible to make 100 stroke up to 2000 by the 1 mm interval.
Lock plate 2000 1500 Stroke adjusting unit Piston speed (mm/s) Shock absorber 1000
32 40 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 2000 1500 50 63 Note) Contact SMC if the maximum stroke will be exceeded.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com New Concept Connector Type Manifold 1-2-1 2 New Concept Connector Type Manifold Series SV1000/2000/3000/4000 Series SV1000/2000/3000/4000 Series SV1000/2000/3000/4000 Product is CE compliant with standard part number.
(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.
A Q value of approximately 620 Nl/min is obtained. 1500 2000 1500 2000 4.The 620 Nl/min.theoretical value is multiplied by 1.4 Q = 620 Nl/min. 1.4 Q = 870 Nl/min. 160 1000 1000 Maximum air consumption Q [Nl/min.]
(Initial value) Note 3) Value for high pressure type (1.5W) specifications Note 4) Value for low power consumption (0.5W) specifications 64 Series VQ1000/2000 VQ1000/Flat Cable Kit with Terminal Block Stations VV5Q11G0-(D) Broken lines and dimensions inside ( ) indicate type [-D] (with DIN rail mounting bracket).
2000 m mL/ L/mi min 8 to 2000 mL/min PB1013A and PB1313A are available up to 1000 mL/min.
Core wire color : DRAIN Black: VBlue: CAN L 1 2 3 4 5 Red: V+ White: CAN H Connections EX9-AC 005 DN-SSPS (With connector on both sides (Socket/Plug)) L 44.5 47.3 14.8 14.8 Cable length (L) Metal parts Metal parts 22.5 005 500 mm 010 1000 mm 020 2000 mm 030 3000 mm 050 5000 mm 100 10 mm 6.7 Marker tag Marker tag M12 SPEEDCON M12 SPEEDCON CANopen Terminal no. Terminal no.
3000 6000 12000 PF2M7(-L) 0.001 L/min 0.01 1 0.02 2 0.01 L/min 0.05 5 Dry air N2 Ar CO2 0.1 10 Thermal type (MEMS) 0.3 25 0.1 L/min 0.5 50 1 100 1 L/min 2 200 PFMB 2 200 Thermal type (MEMS) 5 500 Dry air N2 1 L/min PFG300 10 1000 Bypass flow type 20 2000 PFMC(-L) Thermal type (MEMS) 5 500 Dry air N2 1 L/min PFG300 10 1000 Bypass flow type 20 2000 PF2A 1 10 0.1 L/min 0.5 L/min 5 50 Thermal