S 6-2. XLD-63 XLD-80 XLD-25 XLD-40 XLD-50 XLD-100 XLD-160 0.08 Nm 0.3 Nm 6-3.S S S S 6-4.M M M S 6-5./ S M S M 12 XL-OMY0002 7.
Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Number of auto switches Mounting Bore size 12 16 20 25 32 40 50 Nil S n 2 pcs. 1 pc. n pcs.
P Port size B Model A C D E F K L M Grommet: G Conduit: C DIN terminal: D Conduit terminal: T S 68 71 74 74 U 81 91.5 101 103.5 S 51 54 57 57 Q 98 101 104 104 R 36 44 53 55.5 R 40 48 56 58.5 Q 46 50 52 52 R 36 44 53 55.5 Q 63 66 69 69 R 35 42 51 53.5 Q 27 30 32 32 VCA21 VCA31 41 50 60 68 18 24 30 35 64 76 86 91 28 34 40 40 11.5 14 15 17.5 15 17 20 20 20.5 25 30 34 12.8 19 23 23 M4 M5 M5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com V (mm/s) = Auto switch operating range (mm) Load operating time (ms) x 1000 Current to operate load (OFF condition) > Leakage current If the condition given in the above formula is not met, it will not reset correctly
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Non-locking push type M5 x 0.8 VT For N.O.
rate: 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load rate: 50% Stroke 300 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation SY3140-01 Horizontal actuation 800 700 600 500 400 300 200 100 0 SY5140-02 800 700 600 500 400 300 200 100 0 SY7140-03 800 700 600 500 400 300 200 100 0 SY9140-04 Cylinder is in extending.
After the machine has stopped, make sure to turn off the breaker of the users equipment (on the upstream side). 2 h 1 h 30 min 20 min 14 min 10 min 6 min 4 min 2 min 1 min Operating time 30 s 20 s Max. 10 s 5 s 2 s Min. 1 s 0.5 s 0.2 s 0.1 s 0.05 s 0.02 s 0.01 s 100 135 200 300 400 500 600 700 1000 1500 2000 3000 4000 Current (% for chiller main breaker volume) 341 HRL Series Specific Product
Make sure to connect a speed controller and adjust it to a speed of 500 mm/s or less to operate the cylinder.
CRA1 CRJ U 05 90 E M9B S With external stopper CRQ2 Number of auto switches MSQ Nil S 2 pcs. 1 pc.
u s d Particulate generation has been reduced at the stroke ends by reducing impact using a sine cushion and by stopping the stroke using an internal stopper. i e Reduction of outgassing due to surface treatment n Impact acceleration [m/s2] o u d t R g g e a c 1 s u s d 5 i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated
Very low speed (7 to 50mm/s) specifications There is no sticking and slipping even at very low drive speeds of 7 to 50mm/s. Furthermore, there is no lurching at start up, allowing smooth drive through the entire stroke.
or less Repeatability 1% F .S. or less Operating voltage 12 to 24 VDC (Ripple 10% or less ) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 25 mA or less 45 mA or less 26, 27: 50 mA or less 67: 60 mA or less Current consumption Pressure indication 3 1/2 digits (Letter
CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Number of auto switches Built in magnet Nil S n 2 pcs. 1 pc. n pcs.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZM With valve 07 5 K E15 LZ 1 S A H L Supply valve, Release valve ZM 07 H 2 E15 L Without valve Vacuum switch electrical entry Nozzle diameter Nil L Grommet type, with 0.6 m lead wire Grommet type, with 3 m lead wire C Connector type, with 0.6 m lead
Very low speed (7 to 50mm/s) specifications There is no sticking and slipping even at very low drive speeds of 7 to 50mm/s. Furthermore, there is no lurching at start up, allowing smooth drive through the entire stroke.
S S Effective area ratio 3.2 : 1 Pressure loss: Small Filter regulator S coupler Coil tube 2 Nozzle 2 Upstream side S: 9 Nozzle side S: 2.8 Effective area (mm) Effective area ratio Nozzle size (mm) Number of nozzles Supply pressure S: S = 3.2 : 1 2 1 0.5MPa 0.35MPa 0.33MPa Regulator pressure Outlet pressure Effect of Energy Saving Improvement 50 to 75% Reduction 50 to 75% Reduction 100%
D0 D1 D2 U0 U1 U2 1 to 16 stations Kit L Kit L SD S Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (16 output points) Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (8 output points) DeviceNet OMRON Corp.: CompoBus/S System (16 output points) OMRON Corp.: CompoBus/S System (8 output points) CC-Link Note 1) For the T kit and S kit, 2 stations are required to mount the terminal block
) 258-9200-www.stevenengineering.com Manifold gasket Manifold gasket Applicable base Applicable base VV3K3-20 21 VV5K3-20 21 VK300-45-1 Sub-plate VV3K3-40 (S) 42 VV5K3-40 (S) 41 (S) 42 Manifold base Manifold base Caution Mounting Screw Tightening Torques M3: 0.6 Nm Body ported VK300-41-1A Base mounted VK300-41-2A Manifold gasket and screw assembly Note 1) Mounting direction is fixed, do not
Response time (With anti-chattering function) Output short circuit protection Display 2% F .S. 1 digit or less (at ambient temperature of 25 3C) Green LED (OUT1: Lights when ON), Red LED (OUT2: Lights when ON) Output voltage: 1 to 5 V 5% F.S. or less (in rated pressure range) Linearity: 1% F .S. or less Output impedance: Approx. 1 k No-voltage input (Reed or solid state), input 5 ms or more
Port S (10) remains pressurized and valve S (18) remains open.