SMC Corporation of America
Elite Part Number Search
Search Results "LEY32DEA-300M-M5C918-X8"

Rated Flow Range: 0.5 to 20 L/min, Output Specifications: OUT 1: PNP; OUT 2: Analog 4 to 20 mA; Integrated Display Type, Port Size: 1/2; Applicable to LFE1, Thread: G, Option: Lead Wire w/M12 Connector; gal/min Unit Specification, Insulation Type: Piping Port is Insulated with the Power Supply, Piping Connection: Stainless Steel 304

Rated Flow Range: 2.5 to 100 L/min, Output Specifications: OUT 1: PNP; OUT 2: PNP; Integrated Display Type, Port Size: 3/4; Applicable to LFE2, Thread: NPT, Option: L/min Unit Specification, Insulation Type: Piping Port is Insulated with the Power Supply, Piping Connection: Stainless Steel 304

Rated Flow Range: 5 to 200 L/min, Output Specifications: OUT 1: NPN; OUT 2: NPN; Integrated Display Type, Port Size: 1; Applicable to LFE3, Thread: NPT, Option: Lead Wire w/M12 Connector; L/min Unit Specification, Insulation Type: None, Piping Port is Connected to Negative ground of Power Supply), Piping Connection: Stainless Steel 304

Rated Flow Range: 2.5 to 100 L/min, Output Specifications: OUT 1: PNP; OUT 2: Analog 4 to 20 mA; Integrated Display Type, Port Size: 3/4; Applicable to LFE2, Thread: NPT, Option: Lead Wire w/M12 Connector; Bracket; L/min Unit Specification, Insulation Type: Piping Port is Insulated with the Power Supply, Piping Connection: Stainless Steel 304

ELECTROMAGNETIC FLOW SWITCH. A46. 855.00000 lb. DIGITAL FLOW SWITCH, ELECTROMAGNETIC.

Accuracy: H (High Precision Type), Size: 32, Motor Mounting Position: D (In-line), Motor Type: NY (Mounting Type Y), Lead Screw: B [LEY25, 6mm; LEY32, 8mm, (10); LEY63, 10mm], Stroke: 300mm, Dust/Drip Proof: Size 25, 32: w/o Enclosure; Size 63: IP5x, Dust Proof Specification, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included)

Magnet: None, Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 056 (9/16"), Stroke: 300 (3"), Body Option: M (Male Rod End)

Accuracy: Basic Type, Size: 32, Motor Mounting Position: D (In-line), Motor Type: NZ (Mounting Type Z), Lead Screw: B [LEY25, 6mm; LEY32, 8mm, (10); LEY63, 10mm], Stroke: 300mm, Dust/Drip Proof: Size 25, 32: w/o Enclosure; Size 63: IP5x, Dust Proof Specification, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included)

Size: 32, Motor Mounting: Left Side Parallel Type, Motor Type: S7 [AC Servo Motor, (Absolute Encoder), Output 200W], Lead: B [LEY25, 6mm; LEY32, 8(10)mm], Stroke: 300mm, Motor Option: w/o Option, Rod End: Rod End Male Thread, 1 Rod End Nut Included, Mounting: -, Actuator Cable Type: -, Cable Length: -, Controller Type: -, I/O Connector: -

Size: 32, Motor Mounting: Top Mounting Type, Motor Type: S7 [AC Servo Motor, (Absolute Encoder), Output 200W], Lead: A [LEY25, 12mm; LEY32, 16(20)mm], Stroke: 300mm, Motor Option: w/o Option, Rod End: Rod End Male Thread, 1 Rod End Nut Included, Mounting: -, Actuator Cable Type: -, Cable Length: -, Controller Type: -, I/O Connector: -

Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Both Ends Tapped, Body Options

Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Both Ends Tapped, Body Options:

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

Size: 100, Motor Mounting Position: D (In-line), Motor Type: T9 (AC Servo Motor, Absolute Encoder), Lead: L (2mm), Stroke: 300mm, Motor Option: w/o Option, Rod End Thread: M (Rod End Male Thread)

Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Both Ends Tapped, Body Options: Male Rod

Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Both Ends Tapped, Body Options: Male Rod

Cylinder (Tube) Inner Diameter(φ): 2", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Both Ends Tapped, Body Options: Male Rod End

Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Through hole, Body Options: Male Rod End

Cylinder (Tube) Inner Diameter(φ): 2", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Through hole, Body Options: Male Rod End, Auto

Cylinder (Tube) Inner Diameter(φ): 2 1/2", Stroke(mm): 3", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Through hole, Body Options: Male Rod End