Built-in magnet for auto-switches CE1 CE2 Maximum Driving Speed of Cylinders ML2B 1000 1000 900 900 C J G5-S Load factor: 10% Load factor: 50% 800 800 Cylinder speed (mm/s) Cylinder speed (mm/s) 700 700 600 600 CV 500 500 400 400 MVGQ 300 300 200 200 CC 100 100 0 0 12 16 20 25 32 40 50 63 80 100 RB SYJ3000 VZ3000 VZ5000 VF3000 Bore size (mm) J Series Variations DDetailed specifications
Area: (800) 258-9200-www.stevenengineering.com Nominal symbol C76 Mounting bracket diagram 32 40 (MPa) Lateral load applied to the rod end fR (N) Foot: L Rod side flange: F Head side flange: G 0.3 58 54 10.0 L C7640 44 0.5 40 W W W F 36 0.7 33 C7632 24 0.3 23 G 17 0.5 16 1.0 13 0.7 13 Clevis: C, D Rod side trunnion: U 0.3 C 0.5 W W D 0.7 0.1 (100) (100) 0.3 600 500 400 300 1000 1100 900
CDH10 U L CX CZ ZZ + Stroke Z + Stroke RR (mm) Stroke range Bore size (mm) U RR +0.3 +0.1 L CDH10 CX CZ Z ZZ 20 25 32 40 50 63 80 Up to 250 Up to 350 Up to 600 Up to 600 Up to 700 Up to 900 Up to 900 14 14 17 17 26 26 30 10 10 14 14 22 22 25 14 14 20 20 30 30 32 28 28 40 40 60 60 64 8.5 11 12 15 18 23 28 23 23 30 30 42 42 50 129 151 185 208 237 263 298 137.5 162 197 223 255 286 326 8-25-24
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 16 100, 200, 300, 400, 500, 600, 700, 800, 900 1000, 1200, 1400, 1600, 1800, 2000 3000 25, 40 5000 Strokes are manufacturable in 1 mm increments, up to the maximum stroke. When exceeding a 2000 mm stroke, specify -XB11 at the end of the model number.
a piston speed that will not exceed the absorption capacity of the air cushion and stroke adjusting unit. 80 10 70 45 25 1.96 8.83 4.22 6.86 8.34 Extended Spring force (N) 4.22 20.01 6.86 15.98 20.50 Compressed Operating temperature range (C) Standard Stroke 5 to 60 Bore size (mm) Max. manufacturable stroke (mm) Standard stroke (mm) Weight Unit: kg 100, 200, 300, 400, 500, 600 700, 800, 900
When air is supplied from the unlocking port, y the piston for locking ascends and releases the lock. 3 Centering Unit MACM Series How to Order X114 4 P 20 MACM Centering unit Made to order (Table material) X114 Stainless steel Ultra high molecular weight polyethylene Cast nylon X115 X116 Allowable load weight Symbol Allowable load weight 2 450 lbf [2 KN] 4 900 lbf [4 KN] 6 1350 lbf [6 KN
Refer to the cylinder catalog for details. 11 Optimum Actuation Size Chart of Air Cylinder For JSY5000, A, B port: 12 EX120 EX260 EX250 EX600 EX245 Chart Valve Lead Wire D-sub Flat Ribbon Terminal Block Connector Connecting Base Horizontal Vertical (Upward) Average speed [mm/s] 0 100 200 300 400 500 600 700 800 900 1000 50 63 Plug-in Common Dimensions Made to Order Manifold Exploded View
12 19 25 3/16" 1/8" 1/4" 3/8" 1/2" 3/4" 1" 2 3 Union elbow reducing LQ1E-R LVC 4 5 LVA P.889 6 LVH 2 LVD 3 Union tee reducing LQ1T-R 4 LVQ 5 LVP P.891 6 2 LVW 3 Panel mount union reducing LQ1P-R LQ1 LQ1 4 LQ3 5 P.896 6 LVN 2 LQHB 3 Union reducing LQ1U-R TL TIL 4 5 TLM TILM P.897 6 TD TID 2 TH TIH 3 Space saving union elbow LQ1E-SS 4 5 SMC P.898 6 2 3 Space saving union tee LQ1T-S 4 5 P.900
Water Cooled substance mass m : (= x V) [kg] Cooled substance density : 1 [kg/L] Cooled substance total volume V : 250 [L] Cooled substance specific heat C : 4.186 x 103 [J/(kgK)] Cooled substance temperature when cooling begins T0 : 305 [K] (32 [C]) Cooled substance temperature after t hour Tt : 293 [K] (20 [C]) Cooling temperature difference iT : 12 [K] (= T0 Tt) Cooling time it : 900
Water Cooled substance mass m : (= x V) [kg] Cooled substance density : 1 [kg/L] Cooled substance total volume V : 150 [L] Cooled substance specific heat C : 4.186 x 103 [J/(kgK)] Cooled substance temperature when cooling begins T0 : 303 [K] (30 [C]) Cooled substance temperature after t hour Tt : 293 [K] (20 [C]) Cooling temperature difference iT : 10 [K] (= T0 Tt) Cooling time it : 900
Q = m x C x (T0 Tt) it = r x V x C x iT it = 1 x 20 x 4.2 x 103 x 12 900 = 1120 [J/s] 1120 [W] Q = m x C x (T0 Tt) it x 860 = c x V x 60 x C x iT it x 860 Cooling capacity = Considering a safety factor of 20%, 1120 [W] x 1.2 = 1344 [W] = 1 x 20 x 60 x 1.0 x 103 x 12 15 x 860 1120 [W] Thermo-chiller Q x t: Heat capacity [kJ] 20C Water bath Cooling capacity = Considering a safety factor
HRZ x V x C x iT it m x C x (T0 Tt) it Q = = HRZD 1 x 150 x 4.186 x 103 x 10 900 = = 6977 [J/s] 7.0 [kW] m x C x (T0 Tt) it x 860 x V x 60 x C x iT it x 860 HRW Q = = Cooling capacity = Considering a safety factor of 20%, 7.0 [kW] x 1.2 = HECR 1 x 150 x 60 x 1.0 x 103 x 10 15 x 860 8.4 [kW] = HEC Q x t: Heat capacity [kJ] Thermo-chiller Water bath 6977 [W] = 7.0 [kW] 20C HEB Cooling
Water Cooled substance mass m : (= x V) [kg] Cooled substance density : 1 [kg/L] Cooled substance total volume V : 150 [L] Cooled substance specific heat C : 4.186 x 103 [J/(kgK)] Cooled substance temperature when cooling begins T0 : 303 [K] (30 [C]) Cooled substance temperature after t hour Tt : 293 [K] (20 [C]) Cooling temperature difference iT : 10 [K] (= T0 Tt) Cooling time it : 900
Water Cooled substance mass m : (= x V) [kg] Cooled substance density : 1 [kg/L] Cooled substance total volume V : 300 [L] Cooled substance specific heat C : 4.186 x 103 [J/(kgK)] Cooled substance temperature when cooling begins T0 : 305 [K] (32 [C]) Cooled substance temperature after t hour Tt : 293 [K] (20 [C]) Cooling temperature difference iT : 12 [K] (= T0 Tt) Cooling time it : 900
Water Cooled substance mass m : (= x V) [kg] Cooled substance density : 1 [kg/L] Cooled substance total volume V : 150 [L] Cooled substance specific heat C : 4.186 x 103 [J/(kgK)] Cooled substance temperature when cooling begins T0 : 303 [K] (30 [C]) Cooled substance temperature after t hour Tt : 293 [K] (20 [C]) Cooling temperature difference iT : 10 [K] (= T0 Tt) Cooling time it : 900
Large Flow Air Filter AF800/900 Series AC-A Standard Specifications AF-A AF900 AF800 Model AF-A 1 4 1 2 Port size 1 2 1 AR-A Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa AL-A 5 to 60C (No freezing) Ambient and fluid temperature Standard specifications: 5 m Option: 2, 10, 20, 40, 70, 100 m Polycarbonate Filtration Bowl material AW-A Bowl capacity (cm3) 45 cm3 AC-B Weight (kg)
2.12 (53.8) AP1200HF 150 psig (1.0 MPa) 50 psig (0.35 MPa) Inlet pressure: 100 psig (0.69 MPa) Max. 6.5 (165.1) (When selecting the option code FC) Max. 5.6 (142.2) (When selecting the option code SC) 120 0.83 100 0.69 Delivery pressure (MPa) Delivery pressure (psig) Max. 6.0 (152.4) 1.5 (38.1) 80 0.55 60 0.41 2.62 (66.5) 40 0.28 20 0.14 0 0.00 0.69 (17.5) 0 100 200 300 400 500 600 700 800 900
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or
-14 1 1/2 B(38.1) (P1) () 12 50A 711 900-20 2 B(50.8) (P2) () 10 (),12(P1) 10(P2) EXH , 6 VN-OMP0002 1 2 3 () 4 P2 5 6 7 8 9 10 11 O O 12 13 14 7 VN-OMP0002 No. 1 2 3 4 5 , 6 7 8 9 10 11 P2N.C.