Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 6 Inch, Adjuster: Adjuster Bolt, Auto Switch: F7PV--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Vertical, 0.5M, Number: -

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 6 Inch, Adjuster: Adjuster Bolt, Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 0.5M, Number: -

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 6 Inch, Adjuster: Adjuster Bolt, Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M, Number: -

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 6 Inch, Adjuster: Adjuster Bolt, Auto Switch: J79--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, 0.5M, Number: -

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 6 Inch, Adjuster: Adjuster Bolt, Auto Switch: J79CL--Solid State, Gen. Purpose, 2 Wire, Connector, Vertical, 3M, Number: -

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 6 Inch, Adjuster: Adjuster Bolt, Auto Switch: J79WL--Solid State, 2-color Indication, 2 Wire, Horizontal, 3M, Number: -

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 6 Inch, Adjuster: Adjuster Bolt, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 0.5M, Number: 4 pcs.

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 6 Inch, Adjuster: Adjuster Bolt, Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, 0.5M, Number: -

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 6 Inch, Adjuster: Adjuster Bolt, Auto Switch: A73HZ--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 5M, Number: -

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 6 Inch, Adjuster: Adjuster Bolt, Auto Switch: F7LF--Solid State, Diagnostic, 4 Wire NPN, Lead Wire, Horizontal, 0.5M, Number: -

Step Request data Response data Operation details 01 10 0600 000A Alarm history command to clear alarm 14 0 0 0 0 1 01 10 0600 000A history sent. (0 to 10 entries) 0 0 0 0 0 0 01 10 060A 000A Alarm history command to clear alarm 14 0 0 0 2 01 10 060A 000A history sent. (11 to 20 entries) 0 0 0 0 0 0 0 67 - Caution Ensure the alarm history is cleared only after taking corrective action in

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 150 (1 1/2"), Stroke A: 0600 (6"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0600 (6"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 150 (1 1/2"), Stroke A: 0600 (6"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0600 (6"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl.

Magnet: None, Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 0600 (6"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0600 (6"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)

Magnet: None, Mounting: X (Double Head Side Clevis), Bore Size: 400 (4"), Stroke A: 0600 (6"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0600 (6"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl.

Magnet: D (Built-in), Mounting: X (Double Head Side Clevis), Bore Size: 400 (4"), Stroke A: 0600 (6"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0600 (6"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCY2S GUIDED CYLINDER, IE, 25MM NCY2S DBL-ACT AUTO-SW

Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy

Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, SLIDER, ACTUATOR, NCY2S GUIDED CYLINDER, IE, 25MM NCY2S DBL-ACT AUTO-SW, .00000 lb