Magnet: None, Mounting: Rear screw clearance hole, Overall Length: Standard, Bore Size: 4", Stroke: 2 1/2", Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: High Temperature, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: None, Mounting: Rear screw clearance hole, Overall Length: Standard, Bore Size: 4", Stroke: 1/4", Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: High Temperature, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: None, Mounting: Rear screw clearance hole, Overall Length: Standard, Bore Size: 4", Stroke: 3/8", Body Option: Male Rod End, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: None, Speed Control Type: Universal, Applicable Tubing: 1/4", Suffix: Required Selection w/Speed Control
Series: LEY, Size: 25, Motor Mounting Position: D (In-line), Motor Type: G (High Performance Battery-less Absolute, Step Motor, 24 VDC), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 40: 8mm), Stroke: 400mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End, Male Thread; 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Parallel, In-line), Actuator Cable Type, Length
Cylinder (Tube) Inner Diameter(φ): 3/4", Stroke(mm): 4", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Through hole, Body Options: Rubber Bumper
Cylinder (Tube) Inner Diameter(φ): 2", Stroke(mm): 4", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Both Ends Tapped, Body Options: Rubber Bumper
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 400mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 1P (LECP1, PNP, Programless Type), I/O Cable Length
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 400mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: Without Cable, Actuator Cable Length: Without Cable, Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable
Size: 40, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 400mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct
Size: 25, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 400mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 1P (LECP1, PNP, Programless Type),
Cylinder (Tube) Inner Diameter(φ): 2", Stroke(mm): 4", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Both Ends Tapped, Body Options: Rubber Bumper
Cylinder (Tube) Inner Diameter(φ): 3/4", Stroke(mm): 4", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Through hole, Body Options: Rubber Bumper
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 200 (2"), Stroke: 400 (4"), Body Option: CM (Rubber Bumper & Male Rod End), Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 056 (9/16"), Stroke: 400 (4"), Body Option: C (Rubber Bumper), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC4 (Scraper)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 106 (1 1/16"), Stroke: 400 (4"), Body Option: CM (Rubber Bumper & Male Rod End), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: C (Rear Clevis), Overall Length: Standard, Bore Size: 106 (1 1/16"), Stroke: 400 (4"), Body Option: CM (Rubber Bumper & Male Rod End), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 075 (3/4"), Stroke: 400 (4"), Body Option: CM (Rubber Bumper & Male Rod End), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 4 pcs.
Magnet: D (Built-in), Mounting: B (Through Hole), Overall Length: Standard, Bore Size: 075 (3/4"), Stroke: 400 (4"), Body Option: CM (Rubber Bumper & Male Rod End), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 400mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 400mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type