SMC Corporation of America
Elite Part Number Search
Search Results "PF2W520-F04-1"

Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Option: Standard, Attachment: Standard, Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard

Body Size: 40, Backflow: w/o Backflow Function, Thread: F (G), Port Size: 04 (1/2), Options: w/o Mounting Option, Set Pressure: 1 (0.02 to 0.2 MPa Setting), Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa

Body Size: 40, Backflow: K (w/Backflow Function), Thread: F (G), Port Size: 04 (1/2), Options: w/o Mounting Option, Set Pressure: 1 (0.02 to 0.2 MPa Setting), Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa

Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Option: Standard, Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard

25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns470 g3/8, 1/2

25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns470 g3/8, 1/2

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Remote type sensor unit , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", IFW", "DIGITAL FLOW SWITCH

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Remote type sensor unit , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", IFW", "DIGITAL FLOW SWITCH

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material

Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Option: Standard, Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard

Nozzle Diameter: ø2.0mm, Vacuum Pressure: -90 kPa, SUP: Screw-in G3/8, VAC: Screw-in G1/2, EXH: Screw-in G1/2, Accessories: -

Nozzle Diameter: ø2.0mm, Vacuum Pressure: -48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A, SUP: Screw-in G3/8, VAC: Screw-in G1/2, EXH: Screw-in G1/2, Accessories: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, 1.04719 lb

Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is

Atomizes lubricant into fine particles at uniform rate, Drip rate easily monitored with sight dome, Can be refilled under pressure, High-response time, Damper precludes oil flooding, LUBRICATOR, AIRLINE EQUIPMENT, AL MASS PRO, FA, AL MASS PRO 1/2 MODULAR (PT), 4.82781 lb

25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller.490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns470 g3/8, 1/2