This is a legacy product. Please contact us for the latest version.sales@ocaire.com, IFW/PFW NO SIZE ALL OTHER, INSTRUMENTATION, IFW/PFW NO SIZE ALL OTHER, 2.42508 lb, ModelApplicable fluidDetection methodRated flow rangeDisplay flow rangeSet flow rangeMinimum setting unitConversion of accumulated pulseFluid temperatureDisplay unitAccuracyRepeatabilityTemperature characteristicsOperating
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, IFW/PFW NO SIZE ALL OTHER, INSTRUMENTATION, IFW/PFW NO SIZE ALL OTHER, 2.42508 lb, ModelApplicable fluidDetection methodRated flow rangeDisplay flow rangeSet flow rangeMinimum setting unitConversion of accumulated pulseFluid temperatureDisplay unitAccuracyRepeatabilityTemperature characteristicsOperating
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.? Designed to work with fluids up to 90
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.? Designed to work with fluids up to 90
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the sele, DIGITAL FLOW SWITCH FOR WATER, DIGITAL FLOW SWITCH, WATER, PF3W, F19, 999 lb
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.? Designed to work with fluids up to 90
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.? Designed to work with fluids up to 90
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90ºC
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90ºC
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 14 (1 1/2), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 14 (1 1/2), Output Specification: K (OUT 1: Analog 4 to 20mA; OUT 2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 12 (1 1/4), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 12 (1 1/4), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: gal/min; Accumulated Flow: gal; Temperature
Type: [Flow Switches] Flow Switch, Fluid Type: Water, Flow Range(l/min): 100~Less than 500, Sensor, Monitor Structure: [Integrated Type] Display Integrated, Output Method: NPN Open Collector, Analog Output Specification: -, Pipe Port Type: [Direct Mounting] Direct Attached, Pressure Type: Standard, Pressure Resistance(MPa): 1, Flow Rate Type: Standard, Operating Humidity Range(%): 35~85,
Rated Flow Range: 50 to 250 L/min, Port Size, Pipe O.D.: Port Size: 30A, Pipe O.D.: 38mm, Output Specification: OUT1: NPN; OUT2: Analog 1 to 5V, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 50 to 250 L/min, Port Size, Pipe O.D.: Port Size: 30A, Pipe O.D.: 38mm, Output Specification: OUT1: NPN; OUT2: NPN, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 50 to 250 L/min, Port Size, Pipe O.D.: Port Size: 30A, Pipe O.D.: 38mm, Output Specification: OUT1: NPN; OUT2: Analog 4 to 20mA, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 50 to 250 L/min, Port Size, Pipe O.D.: Port Size: 30A, Pipe O.D.: 38mm, Output Specification: OUT1: PNP; OUT2: PNP, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 50 to 250 L/min, Port Size, Pipe O.D.: Port Size: 30A, Pipe O.D.: 38mm, Output Specification: OUT1: PNP; OUT2: Analog 4 to 20mA, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: -
Rated Flow Range: 50 to 250 L/min, Port Size, Pipe O.D.: Port Size: 30A, Pipe O.D.: 38mm, Output Specification: OUT1: PNP; OUT2: Analog 4 to 20mA, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -