SMC Corporation of America
Elite Part Number Search
Search Results "RDLQF32TF-75-F-M9PWSDPC"

-30 to 180 F Performance Data 90 PS Swivel 150 SUS Oil Flow vs.

M12 x 1.0 12.5 9.5 47 6 9 75 4 Series CJ5-S Dimensions R V Front flange type (F)/CJ5FS CA Rod cover side GB Piping port 2-M5 x 0.8 Piping port M5 x 0.8 GA NN MM Cover surface BA CB D FY FB 2-FC With head cover port in axial position (R) Mounting hole NB A BB FX FZ NA F FT S + Stroke Z + Stroke H (mm) A BA BB CA CB D F FB FC FT FX FY FZ GA GB H MM NN NA NB S Z Bore size (mm) 10 15 15 12

AMD AMH Data A: Inlet Air Temperature Data B: Ambient Temperature Data C: Inlet Air Pressure AME Inlet air temperature Ambient temperature Inlet air pressure MPa psi Correction factor F C Correction factor AMF Correction factor IDFB3E to 37E IDFB55E, 75E 1.31 F C 77 90 95 100 104 25 32 35 37.8 40 75 100 110 120 125 150 175 200 232 0.53 0.70 0.76 0.83 0.86 1.03 1.21 1.38 1.60 1.24 0.95 ZFC

1N X430 03 AR 30 BG F N X425 03 Regulator Regulator For high/low temperature For high pressure 25 30 40 50 60 Body size Body size X430 X440 Low temperature 20 25 30 40 50 60 High temperature Thread type Thread type Rc NPT G Nil N F Rc NPT G Nil N F Port size Port size Body size Port size Body size Symbol Port size 25 30 40 50 60 Symbol 20 25 30 40 50 60 02 03 04 06 10 1/4 01 02 03 04 06 10

How to Order JA 40 F 14-150 Option Mounting type None Nil High temperature specifications 5 to 100C Nil F L Basic type Flange type Foot type Applicable bore size (mm) X11 Symbol Applicable bore size (mm) Model 6 10 15 20 30 40 63 80 100 140 160 6 10 10, 15 20 25, 32 40 50, 63 80 100 125, 140 160 Thread nominal size (Standard) Nominal thread size Applicable cylinder nominal thread size Standard

I/F DICOM CN3-5 DC24V(DC24V10% 150mA) DC24V CN3-10 DC24V I/F DOCOM CN3-3 EM1LG DC24V DC24V LG CN3-1 MO1MO2 CN3-11 SD 3 22 3 3.6 OFFON CPU () ON ON OFF OFF ON ON OFF OFF ON ON ON () OFF () OFF 1s ON ON () OFF 50ms 60ms () OFF 50ms 60ms .

64 53.5 10 to 50 63.5 17.5 depth 13.5 80 73.5 63.5 21 25 98 12.5 M16 x 2.0 132 6 22 10 77 11 3/8 16 112.5 57.5 26 63.5 75, 100 73.5 63 10 to 50 75 17.5 depth 13.5 100 85 73 27 30 117 13 M20 x 2.5 156 6.5 27 12 94 11 3/8 23 132.5 67.5 26 73 75, 100 85 7

type (Except for 6) Single clevis type (Non-integrated type) Double clevis type 10 15, 30, 45, 60, 75, 100 16 15, 30, 45, 60, 75, 100 20 15, 30, 45, 60, 75, 100 25 15, 30, 45, 60, 75, 100 Strokes are available in 1mm increments by installing spacers in standard stroke cylinders.

FC Mounting hole B 0 0.3 A F NA FT NB FX FZ H S + Stroke F Z + Stroke Refer to page 8 for details of the mounting nut.

EX600-DX#D/E/F (5 byte) Byte Bit Parameter Setting value 0..3 Unit No. 0..8 0 4..7 Parameter type 1 EX600-DX#D: 05 (Hex) EX600-DX#E: 14 (Hex) EX600-DX#F: 16 (Hex) 1 0..7 Unit ID Unit parameter 0 Monitor short circuit (power) 0: disable, 1: enable 1 Reserved 0 2 Inrush current filter 0: disable, 1: enable 2 3 Reserved 0 4..5 Input filtering time 0: 0.1 ms, 1: 1 ms, 2: 10 ms, 3: 20 ms 6..7

L Foot F Rod flange*2 D Double clevis*3 !2 Cable length Note 2) [m] !3 Driver type * When the driver type is selected, the cable is included. Select cable type and cable length.

Action/Double acting. 250 PSr (17.5 8 PSI 40140.F 2 -20 inch/sec (50 Front nose. Double end. Rear Pivot HOWTO ORDER Stock Stroke Li3t ""uE@@@" Ex.) Cushion standard on 76 and l/a bore onlv {must include C if desired on these bore sizes). ultENstoNs r":-t _1-1,--lY+/ 075 {!a) .250 \-24 0.50 .624 .621 0.25 0.86 0.38 it-l6 .251 .zfi 0.75 0.25 o.34 It.oo o.75 o.62 o.12 # 1 8 o.75 1-?

M M H W Y L E 1/8 LQ1H11-F LQ1H12-F LQ1H21-F LQ1H22-F LQ1H23-F LQ1H24-F LQ1H31-F LQ1H32-F LQ1H33-F LQ1H34-F LQ1H35-F LQ1H36-F LQ1H41-F LQ1H42-F LQ1H43-F LQ1H44-F LQ1H51-F LQ1H52-F LQ1H53-F LQ1H54-F LQ1H61-F LQ1H62-F LQ1H63-F LQ1H64-F 4 3 6 4 6 4 10 8 6 10 8 6 12 10 12 10 19 12 19 12 25 19 25 19 11.5 18.5 10 10 26.5 1/8" Class 1 Rc (NPT) Port size 18.5 35 1/8" 16.5 14 14 15 (L) 21.5 36.5

M H L M E W Y 1/8 LQ1H11-F LQ1H12-F LQ1H21-F LQ1H22-F LQ1H23-F LQ1H24-F LQ1H31-F LQ1H32-F LQ1H33-F LQ1H34-F LQ1H35-F LQ1H36-F LQ1H41-F LQ1H42-F LQ1H43-F LQ1H44-F LQ1H51-F LQ1H52-F LQ1H53-F LQ1H54-F LQ1H61-F LQ1H62-F LQ1H63-F LQ1H64-F 4 3 6 4 6 4 10 8 6 10 8 6 12 10 12 10 19 12 19 12 25 19 25 19 11.5 18.5 10 10 26.5 1/8" Class 1 Rc (NPT) Port size VC 18.5 35 1/8" 16.5 14 15 14 L VDW 21.5

, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes other than the above are produced upon receipt of order.

35 54 21.5 34 7 87 15.5 77 75 35 54 24 7 77 Dimensions other than above are identical to the high precision type.

F S TAT I O N S 02 2 Stations to 20 20 Stations S I Z E O F A, B P O R T M5 10-32Nom (P, R Port PT) M5T 10-32Nom (P, R Port NPTF) B3T One Touch Fitting 5/32 B7T One Touch Fitting 1/4 ACCESSORIES M A N I F O L D T Y P E 40 S I D E P O R T E D T Y P E G DXT200-8-1A Blanking Plate Kit Stations (n) 2 3 4 5 6 7 8 9 10 L1 52 68 84 100 116 132 148 164 180 M5x0.8 L2 43 59 75 91 107 123 139 155 171

+ 55 (n 2) (n = 2, 3, 4, 5) 10 15 75 (n = 2, 4, 6) Note 3) (n = 2, 4, 6) Note 3) 20 + 50 (n 2) 2 75 + 55 (n 2) (n = 2, 3, 4, 5) D-B59W 15 20 Note 3) When n is an odd number, an even number that is one larger than this odd number is used for the calculation. 75 100 + 100 (n 2) (n = 2, 3, 4, 5) D-G39/K39 D-A3/A44 35 + 30 (n 2) (n = 2, 3, 4, 5) 10 35 100 Note 1) Auto switch mounting Auto

Lock 15-2-75 4 Series KK Plug (P) Socket (S) Part no. Male thread type Male thread type Body size Port size Part no.

(For F, L, S, T kit) VVQ4000 2A 1 Thread type Electrical entry VVQ4000 3A 1 Thread type Electrical entry Nil Rc N NPT T NPTF F G Nil Rc N NPT T NPTF F G L F , L, S, T kit F Note 1) F kit (Connector location on U side) C C kit (Plug lead type) L F, L, S, T kit F Note 1) F kit (Connector location on D side) C C kit (Plug lead type) SV SYJ Option Option Nil Standard W Note 2) IP65 enclosure