When the source pressure is 1700 psig (11.7 MPa), achievable delivery pressure is around 125 psig (0.86 MPa ) (HF and FC option 120 psig (0.83 MPa)). 2) 250 psig outlet pressure preset at 800 psig (5.5MPa) inlet pressure. Custom inlet/outlet pressure settings available.

Data A Volume of cylinder/Capacity of converter 180 160 140 125 100 300 250 800 700 600 How to Select 200 10,000 8,000 6,000 5,000 4,000 3,000 500 400 qSelect the bore size of air-hydro cylinder 80 First of all, select a bore size from data .

, 300 300 Other intermediate strokes can be manufactured upon receipt of order.

, 300 300 Other intermediate strokes can be manufactured upon receipt of order.

262.5 275 287.5 300 L3 180.5 191 201.5 212 222.5 233 243.5 254 264.5 275 L4 15 16 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 Manual override In case of locking type, ( turn after pushing in ) 4-One-touch fitting (ports P, R) Applicable tube O.D.: 8 (L4) L3 8 U side D side 52.9 <53.6> 4.1 [46] [54.5] 22.5 1 32 P P 5.5 B B A B A B A B A B 4.7 35 23.5 44.4 <45.1> 10.2 26 3 R R A A G: Approx. 300

3 contained in one kit, and can be ordered using the kit number for each cylinder bore size. 2.4-7 Series MUW Basic: MUWB Rod end male thread (mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 Model MUWB25 MUWB32 MUWB40 MUWB50 MUWB63 Stroke range (mm) 5 to 300 5 to 300 5 to 300 5 to 300 5 to 300 D 12 14 16 20 20 C 54 68 86 104 124 B1 17 19 22 27 27

L/min ) (250 L/min ) [cm] -37No.PF-OMN0009CN-F PVC 3F.S.11 cm IN OUT PF3W511/521(PVC ) (100 L/min ) (250 L/min ) [cm] -38No.PF-OMN0009CN-F PF3W504S PF3W520S [] [] P: P: PF3W540S [] P: -39No.PF-OMN0009CN-F () (PF3W504/520/540) A B C 1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W511) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W521-12/14) A B C 1 V 1.8 V 5 V 4 mA 7.2 mA 20 mA (PF3W521-U30) A

Air consumption (l/min (ANR)) 140 120 SUP = 0.5 MPa 100 SUP = 0.3 MPa 80 SUP = 0.2 MPa 60 40 20 1 0 2 3 4 5 6 7 Cycle (Hz) PA513 Air Consumption 400 Air consumption (l/min (ANR)) SUP = 0.5 MPa 350 300 Calculating Air Consumption (PA3000) 250 SUP = 0.3 MPa 200 Find the air consumption for operation with a 4 Hz switching cycle and pilot air pressure of 0.3 MPa from the air consumption graph

158 124 142 63 M10 x 1.5 9 M10 x 1.5 WA WB Bore size (mm) VB X XA XB XC XL YY YL Z st25 25300300300 34 84 122 172 50 4 4.5 3 6 16 22 46 40 M8 x 1.25 92 24 48 124 200 300 36 86 124 174 66 5 6 4 8 20 24 48 50 M10 x 1.5 28 52 128 200 300 38 50 88 124 174 110 80 5 6 4 8 20 24 63 M10 x 1.5 MLGPM (slide

250 250 Lead wire length D-B31 3 m (L) 268 268 268 5 m (Z) 462 462 462 Contacts protection resistance () () Reed switch Neon bulb Current limiting resistance Lead wire length In case of the grommet type (J type), the lead wire length is 0.5 m.

time constants (msec) PE07 100 600 300 150 600 300 150 1000 500 250 800 400 200 Home position return position data (m) PE08 0 -2000 (<1000 stroke)/-200 (>1000 stroke) Stopper type home position return PE10 100 200 stopper time (msec) Stopper type home position return torque limit value (%) PE11 15 30 Regenerative option PA02 000 000 (Non)/002 (LEC-MR-RB-032) 1 1 0 0 Rotation direction selection

M16 x l 250 M16 x l 250 M16 x l 300 M16 x l 300 M16 x l 300 M16 x l 500 M24 x l 500 M24 x l 500 AT6C AT11C AT22C AT37C AT55C AT75C AT125C AT150C AT220C 1 2 Rc 1/2 Rc 3/4 Rc 1 Rc 1 Rc 1 1/4 Rc 1 1/4 Rc 2 Rc 2 Rc 2 Rc 110 110 110 180 180 180 260 260 Rc 3 4 Rc 1 1 2 1 2 Rc 1 2B (JIS 10kFF) 2B (JIS 10kFF) 3B (JIS 10kFF) 4B (JIS 10kFF) 4B (JIS 10kFF) 14-16-2

/N.O.) 2(B) 4(A) C Note 2) L-type plug connector with cover Lead wire length Symbol 3 6 10 15 20 30 100 Lead wire length 300 mm Note LL 5(EA) 3(EB) 1(P) Note 1) 3-position type is not available for the 53-SY9000 series.

300 350 5m 3m ISl Detection distance (m) 1.0 1m ZSM Fig.2 Detection distance vs.

300 350 5m 3m ISl Detection distance (m) 1.0 1m ZSM Fig.2 Detection distance vs.

For response time, refer to the graph below. 400 350 Response time (ms) 300 250 200 150 100 50 0 1 2 3 4 5 6 7 8 9 10 11 12 * This graph shows delay times between gateway unit and controllers. Fieldbus network delay time is not included.

Double acting single rod only 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30 12, 16 5, 10, 15, 20, 25, 30 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches Mounting Bracket Part No.

RS Q G RS H A Relation of Liquid Entry and Sliding Distance Amount of liquid entry (g) x 15 RZQ 10 Standard cylinder MI W S Stainless steel cylinder 5 CEP1 0 50 100 150 200 Sliding distance (km) 250 300 CE1 Conditions Working fluid Air Pressure 0.5 MPa Liquid Water-soluble coolant Piston speed 200 mm/sec (60 cpm) CE2 ML2B Special scraper C J G5-S Exterior configuration reduces residual

North America For Europe For France Special Maximum clamping force (lbf) Maximum clamping force (N) 8000 2000 7000 6000 1500 80 80 5000 4000 1000 63 63 3000 40 50 2000 500 50 1000 40 0 0 5 10 15 20 0 450 400 350 300 250 200 150 100 50 0 Arm length L (mm) Arm length L (in) Allowable load for clamp arm end Refer to the graph on pages 190 and 191 for parts weight of the arm.