Pressure gauge indication range Indication unit ARJ GC3-4A-X2101 0 to 0.4 MPa MPa GC3-10A-X2101 0 to 1.0 MPa Fitting type One-touch fittings for regulator Symbol Nil L1 AR425 to 935 GC3-P4A-X2101 0 to 60 psi Type Straight Elbow psi GC3-P10A-X2101 0 to 150 psi ARX Specifications Fitting size AMR 3% F.S.
Standard Strokes Bore size [mm] Standard stroke [mm] Max. manufacturable stroke 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 45 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 56 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 63 25, 50, 75, 100, 125, 150
When the Hysteresis exceeds 10m use the Air-Catch Sensor as a confirmation of position of work piece. : Stable adjustment range Detection side nozzle: 1.0 Detection side piping: 6 X 4 tubing Detection side nozzle: 2.0 Detection side piping: 6 X 4 tubing Detection side nozzle: 1.5 Detection side piping: 6 X 4 tubing 70 70 70 60 60 60 Supply pressure Supply pressure Detection not possible 50
, 300 71.5 177 27 16 52 57 M14 x 1.5 5 14 136 24 100, 125, 150, 175, 200, 250, 300, 400, 500 85.5 200, 300, 500 193 32 20 64 71 M18 x 1.5 7 18 144 22.5 98.5 200, 300, 500 194 32 20 77 84 M18 x 1.5 7 18 145 21 P M N O T X Z L Q Bore size (mm) 32 40 50 63 41 34 5.5 M6 x 1 Rc(PT) 1/8 57.5 30 14 56 41 40 5.5 M6 x 1 Rc(PT) 1/8 64.5 30 14 62 49 50 6.6 M8 x 1.25 Rc(PT) 1/4 76.5 35 19 61.5 49 60
to 1000 126 114 108 LJ1H303ND 20 62 to 1000 to 1000 to 700 to 500 to 1000 LJ1H102PH-K 24 66 to 400 104 110 LJ1H102NH-K 28 70 to 400 LJ1H202PA-K 34 76 to 500 106 112 LJ1H202NA-K 38 80 to 500 LJ1H102PB-K 26 68 to 600 145 104 110 LJ1H102NB-K 30 72 to 600 LJ1H202PF-K 32 74 to 250 106 112 LJ1H202NF-K 36 78 to 250 LJ1H303PA-K 40 82 to 500 108 114 LJ1H303NA-K 42 84 to 500 Page Standard stroke
Contact capacity 50 VA AC, 50 W DC 1 2 5 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 24 VDC Pressure gauge for supply pressure Pressure gauge for tank pressure Pilot valve Recommended Equipment AIR BLOW Supply pressure AIR It is recommended to use each mist spray unit type with the mixing valves, magnet holders, branch pipes and nylon tubes listed in the table below.
Minimum strokes for mounting of auto switches 40 50 63 Number of auto switches mounted Auto switch model Auto switch type 60 2 pcs. (same side) D-Z73, Z76, Z80 Reed switch 1 pc., 2 pcs. (different sides) 20 2 pcs. (same side) 60 D-Y59A(B), Y69A(B) Y7P(V) 1 pc., 2 pcs. (different sides) 20 2 pcs. (same side) 70 D-Y7NW(V), Y7PW(V) Y7BW(V) Solid state switch 1 pc., 2 pcs.
(Onty auto SWItch mounting bracket ISassembled at the lime of shipment) 2 Air Cylinder Series CS2 Specifications " Bore size (mm) 125 f 140 :1 1 60 . j Action Double actmg.
Pressure gauge indication range GC3-4A-X2102 0 to 0.4 MPa MPa GC3-10A-X2102 0 to 1.0 MPa End block Option GC3-P4A-X2102 0 to 60 PSI PSI Nil 3 None GC3-P10A-X2102 0 to 150 PSI End block type Oil-free Specifications Mounting position Symbol L R Note 1) Since the L side end block is oil-free, leave the field blank for it.
250 70 300 Cautions for Designing the Circuit Surge pressure UWhen the cylinder is operated at high speeds and reaches the stroke end, surge pressure could be created in the rod side or in the head side.
Vacuum pressure [kPa] 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 10 20 30 40 50 60 70 80 90 100 110 120 20 60 100 140 180 220 260 300 130 Suction flow rate [l/min(ANR)] Suction Flow rate [l/min (ANR)] Time to reach vacuum Time to reach vacuum Measurement conditions/Tank capacity: 1l Supply pressure: 0.4MPa Measurement conditions/Tank capacity: 1l Supply pressure: 0.4MPa 100 90 100
Pressure gauge indication range GC3-4A-X2102 0 to 0.4 MPa MPa GC3-10A-X2102 0 to 1.0 MPa End block Option GC3-P4A-X2102 0 to 60 PSI PSI Nil 3 None GC3-P10A-X2102 0 to 150 PSI End block type Oil-free Specifications Mounting position Symbol L R Note 1) Since the L side end block is oil-free, leave the field blank for it.
ISA2-G ISA2-H Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Standard pressure: 100 kPa Standard pressure: 100 kPa Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 2.0 0.4 0.6 Standard pressure Standard pressure 0.5 mm 0.25 mm Detection distance (mm) Detection distance (mm) 0.5 0.3 0.4 0.2 0.3 0.15 mm 0.15 mm 0.2 0.1 0.1 0.03 mm 0.01 mm 0 0 50 0 250 200 150 100 250
125 33.2 33.2 250 250 125 639 230 120 227 2 1 1055 ALD600/900 Series Related Products: Strainer At the terminal of an air pressure line in which a D.P.
175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rod boot Intermediate strokes are available.
250 250 Lead wire length D-B31 3 m (L) 268 268 268 5 m (Z) 462 462 462 Contacts protection resistance () () Reed switch Neon bulb Current limiting resistance Lead wire length In case of the grommet type (J type), the lead wire length is 0.5 m.
ON/OFF LED PLC ST(0) () ON/OFF ST / (60 ) -37No.EX-OMN0029CN-D EX600No. H.T. () LED PLC 0 1 5 AXA / () / / H.T. () LED PLC 6 AYA () / / (60 ) -38No.EX-OMN0029CN-D EX600No. H.T. () LED PLC 0 1 7 AMB / () / / / / H.T. (SI ) ON/OFF LED PLC ON/OFF 8 ST(M) () ST(M) SI 9 ST(M) OFF PWR () DC24 V10 10 PWR(V) () DC24 V+10/-5 (60 ) -39No.EX-OMN0029CN-D No.
Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.