Display LCD LCD with backlight LED Pressure setting range 101 to 10 kPa 101 to 0 kPa Maximum operating pressure 200 KPa Operation indicator light (Lights up when ON) Green OUT1: Green OUT2: Red Response frequency 200 Hz (5 ms) Hysteresis mode Variable (3 digits or more) Variable (can be set from 0) Hysteresis Window comparator mode Fixed (3 digits) Fluid Air, Non-corrosive gas Temperature
Mounting bolt Mounting bolt diagram C D D Model C Mounting bolt Model C D Mounting bolt M5 x 55l x 60l x 65l x 70l x 75l M8 x 95l x 100l x 105l x 110l x 115l CHQB63 10D (M) 5D (M) CH QB20 55 60 65 70 75 80 85 90 95 100 70 75 80 85 90 95 100 105 110 115 140 165 75 80 85 90 95 100 105 110 115 120 145 170 90 95 100 105 110 115 120 125 130 155 180 95 100 105 110 115 120 125 130 135 160 185 100
T2 : Arrival time to stable Pv 95% after adsorption (sec.) QL : Leakage at work adsorption /min (ANR) 2. Max. suction flow rate Qmax = (2 to 3) x Q /min (ANR) Q : Average suction flow rate /min (ANR) V : Piping capacity T1 : Arrival time to stable Pv 63% after adsorption (sec.) T2 : Arrival time to stable Pv 95% after adsorption (sec.) 2.
Withstand Pressure and Heat Resistance Performance 4.0 3.5 3.0 Pressure (MPa) 2.5 2.0 1.5 1.0 0.5 0 20 40 60 80 100 120 140 160 180 200 Temperature (C) 1/8", 3/16", 1/4", 4, 6 tubing 3/8", 10 tubing 1/2", 12 tubing 3/4", 19, 1" tubing Piping Caution 1. Connect tubing with special tools 2.
Example: Depending on the time of day and workload, a plants air pressure fluctuates between 80 and 95 PSI. Set the regulator at 80 PSI and the cylinder power output through the plant will remain constant. Also, an air reservoir may be used to solve an air shortage problem. By mounting a reservoir close to a cylinder, an adequate amount of air will be supplied when needed.
Example: Depending on the time of day and workload, a plants air pressure fluctuates between 80 and 95 PSI. Set the regulator at 80 PSI and the cylinder power output through the plant will remain constant. Also, an air reservoir may be used to solve an air shortage problem. By mounting a reservoir close to a cylinder, an adequate amount of air will be supplied when needed.
VCW 20 1 G Clip Series Lead wire length 20 30 40 300 mm 600 mm 1000 mm 1500 mm 3000 mm Nil L1 L2 L3 L4 Class 2 Class 3 Class 4 Flat head screwdriver Voltage Solenoid coil 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Electrical entry Insert a flat head screwdriver into the hook section of the clip groove.
Fittings & Tubing Air Cylinders Rotary Actuators Action Double acting Operating pressure 0.15 to 0.7 MPa Proof pressure 1.05 MPa 10 to 60C (No freezing) Ambient and fluid temperature 50 to 300 mm/s (Adjuster option/Metal stopper: 50 to 200 mm/s) Piston speed Rubber bumper (Standard, Adjuster option/Rubber stopper) None (Adjuster option/Metal stopper) Cushion Non-lube Lubrication +1 0 mm Stroke
Refer to the above drawing for other dimensions. n L 1 38 28 2 57 47 3 76 66 4 95 85 5 114 104 6 133 123 7 152 142 8 171 161 9 190 180 10 209 199 11 228 218 12 247 237 13 266 256 14 285 275 15 304 294 16 323 313 17 342 332 18 361 351 19 380 370 20 399 389 L1 L2 1417 A VK300 Series Specific Product Precautions Be sure to read this before handling the products.
HOW Replacement Element Part No. 74 m (200 mesh) 105 m (150 mesh) 149 m (100 mesh) Element size Port size (Nominal size) 04 (1/2B) 06 (3/4B), 08 (1B) 10 (1 1/4B), 12 (1 1/2B) 16 (2B) 20 (2 1/2B), 24 (3B) 28 (3 1/2B), 32 (4B) 65 x 90 85 x 110 100 x 160 120 x 180 140 x 200 180 x 260 EM001H-074N EM101H-074N EM201H-074N EM301H-074N EM401H-074N EM501H-074N EM001H-105N EM101H-105N EM201H-105N EM301H
AG E AV AF B Clearance for maintenance 210 Clearance for maintenance G 1/2 Float switch Part number: IS400-1 to 2 210 Bracket mount With float switch Model P A B C Q V B AL30 AL40 AL40-06 AL50 AL60 1/4, 3/8 53 324 38 25 374 1/4, 3/8, 1/2 70 333 40 18 383 3/4 75 333 38 16 383 3/4, 1 90 332 41 35 47 382 1 95 335 45 35 47 385 513 SP093-001I Issued: Sep 2009 P.G.
Refer to the above drawing for other dimensions. n L 1 38 28 2 57 47 3 76 66 4 95 85 5 114 104 6 133 123 7 152 142 8 171 161 9 190 180 10 209 199 11 228 218 12 247 237 13 266 256 14 285 275 15 304 294 16 323 313 17 342 332 18 361 351 19 380 370 20 399 389 L1 L2 4-5-9 10 Series VK300 Precautions Be sure to read before handling.
VK300-37-2-01 VK300-37-2-02 VK300-37-2-07 VK300-37-4-51 VK300-37-4-06 VK300-37-3-05 VK300-37-3-53 A1 A2 A3 LW06 LW2 LD4 LD8 100 VAC 200 VAC 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC 4-13-3 4 For details about the applicable products conforming to international standards, visit us at www.smcworld.com. 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 How to Order Valves Electrical entry
and main valve)type Not required Free 150/30 Dust proof 3 Position closed center 3 Position closed center B A B A P R R P R 3 Position exhaust center 3 Position exhaust center B A B A Solenoid Specifications P R R Grommet(G)/(H), L type plug connector(L), M type plug connector(M) P R Electrical entry 3 Position pressure center 3 Position pressure center DC AC50/60Hz 24,12,6,5,3 100, 110 , 200
Lead-wire length (m) 0.5 (Nil) Rail mounting 32 to 6 Direct mounting 32 to 63 Load voltage Indicator light Electrical entry direction Wiring (output) Special function Pre-wired connector Applicable load None (N) Type 3 (L) 5 (Z) DC AC Perpendicular In-line Perpendicular In-line 3-wire (NPN equiv.) 5 V A96 A96V A76H IC circuit Reed switch Grommet 200 V A72 A73 A73C A79W F7NV F7PV F7BV J79C
4.5 (piping port) IN 7 2-M3 x 0.5 (through) 13 + ST 2-M5 x 0.8 thread depth 4.5 (piping port) (same on reverse side) 10 2-M3 x 0.5 thread depth 4.5 (same on reverse side) 4 8 6 11 22.5 (13) (10 + 1/2ST) 4 Model ST 13 + ST 45 + ST 58.5 + ST 10 + 1/2ST CXS6-10-XB19 10 23 55 68.5 15 CXS6-20-XB19 20 33 65 78.5 20 CXS6-30-XB19 30 43 75 88.5 25 CXS6-40-XB19 40 53 85 98.5 30 CXS6-50-XB19 50 63 95
Lead-wire length (m) 0.5 (Nil) Rail mounting 32 to 63 Direct mount 32 to 63 Load voltage Indicator Electrical entry direction Wiring (output) Pre-wired connector 3 (L) 5 (Z) Applicable load None (N) Type Special function DC AC Perpendicular In-line Perpendicular In-line 3-wire (NPN equiv.) 5 V IC circuit A96 A96V A76H Reed switch Grommet 200 V A93 F9N F9P F9B F9NW F9PW F9BW F9BA A93V
Mounting bolt M6 X 165 with SW M6 X 180 with SW M6 X 185 with SW M6 X 200 with SW Size Option mounting diagram Interface regulator Double check spacer Double check spacer Interface regulator Spacer 1 Throttle valve spacer Spacer 1 Spacer 1 Throttle valve spacer Spacer 1 Spacer 1 Spacer 1 Note 1) A throttle spacer and double check spacer cannot be combined.
Mounting: D (Double Clevis), Bore Size: 63mm, Thread: Rc, Full Stroke: 200mm, First Stroke: 70mm