M1 M2 M3 m1 m2 m3 16 25 40 16 25 40 16 25 40 5 4 3.5 18 16 14 MY2H 13 14 10 35 35 30 45 33 28 68 66 57 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 MY2HT 100 120 100 38 35 35 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load.
Ambient temperature 0 to 40C (No freezing) Ambient humidity 35 to 65%RH (No condensation) Material Case: PBT Emitter: Tungsten Weight (Body only) Standard nozzle 200 g Bypass nozzle 250 g Standards/Directive CE (EMC directive, RoHS directive), UKCA Ambient humidity 20 to 80%RH Safety standards IEC 62368-1 *4 An AC cord included with an AC adapter is only for use in Japan.
Standard Strokes Bore size [mm] Standard stroke [mm] *1 20 25, 50, 75, 100, 125, 150, 200, 250, 300 25 32 40 *1 Intermediate strokes not listed above are produced upon receipt of order. The minimum stroke is 25 mm. Mounting Brackets/Part No.
Material FGFC3-40 Carbon steel F-86S FN AL-79S AL-80S FGF3-40 FGFR3-40 FGFC3-40 159 115 3 10(4B) F-90S F-86S V#6500 210 175 115.4 19 18 FGF5-60 FGFS3-40 FGFR3-40 220 167 3 Stainless steel F-87S AL-79S AI-17S EB ES FGFL3-40 FGFS3-40 Note) 2 pieces are required per filter unit.
Recommended proper torque Nm (kgfcm) 1/8 1/4 3/8 1/2 Connection thread 7 to 9 (70 to 90) 12 to 14 (120 to 140) 22 to 24 (220 to 240) 28 to 30 (280 to 300) Winding direction Torque Expose approx. 2 threads Pipe tape Operating Environment Warning 1.
Rubber stopper Standard stroke (mm) Additional weight of adjuster option Metal stopper Shock absorber Model Axial piping type (S: Stroke mm) With end lock With buffer 20 30 40 50 75 100 125 150 10 Extension end Retraction end Extension end Retraction end Extension end Retraction end MXQ 6 MXQ 8 MXQ12 MXQ16 MXQ20 MXQ25 5 10 100 120 140 180 200 25 5 6 13 + 0.2S 10 23 23 30 140 170 210 250
(H) MY1B MY3A/3B MY3B With air cushion Height(H) (mm) Series 16 25 40 63 MY3A MY3B MY1B 27 37 54 84 MY1B With air cushion 37 54 84 116 Up to 53% reduction Max. 53% Weight Overall length(Z+Stroke) Z dimension Weight (kg) (mm) Series 16 25 40 63 Series 16 25 40 63 MY3A MY3B MY1B 0.34 0.87 2.95 8.26 MY3A MY3B MY1B 110 150 240 320 0.35 0.97 3.08 8.99 122 178 276 356 0.73 1.57 4.41 14.5 160 220
Temperature characteristics Current consumption (No load) Weight Note 3) Port size (Rc, NPT, G) Detection type Indicator light Operating pressure range Proof pressure Accumulated flow range Note 4) 0 to 50C 5% F.S. or less 1% F.S. or less 2% F.S. or less 3% F.S. or less (15 to 35C, based on 25C), 5% F.S. or less (0 to 50C, based on 25C) 160 mA or less 170 mA or less 290 g 150 mA or less 250
(the value under the prescribed conditions) 0.8 0.7 0.6 Subsonic Critical pressure 0.5 0.4 0.45 0.45 Sonic 0.4 0.4 0.35 0.35 0.3 0.3 0.3 0.25 0.2 0.25 0.2 0.2 0.15 0.15 0.1 0.05 0.1 0.1 0.05 S = 0.54 VDW101 10 60 50 40 30 20 10 20 VDW 1.6 S = 1.2 125 100 75 50 S = 3.2 VDW202.3 350 300 250 200 150 100 50 S = 5.8 VDW203.2 600 500 400 300 200 100 S = 2.8 VDW302 300 250 200 150 100 50 VDW303
300 100 0 50 150 200 250 300 100 ()[] ()[] LECSC-S5 LECSC-S7, LECSC-S8 . ()30r/min100% 12.1 12 2 12 12.2 (1) 12.1 12.1 1 (2)[W] (1) [m2] [kVA] LECSC-S5 LE-S5LE-S60.3 25 15 0.5 LECSC-S7 LE-S70.5 25 15 0.5 LECSC-S8 LE-S80.9 35 15 0.7 1.
Line Receiver Circuit Example DRIVE PC or PLC ... etc Applicable line receiver: SN75ALS175 or the equivalent 220 to 470 16 - 2.4 Wiring for Safety cable (1) Connection Example for input signals The input signals must be redundant. DRIVER For safety function signal connections, the input signal is the 0 V common and the output signal is the source output.
Line Receiver Circuit Example DRIVE PC or PLC ... etc Applicable line receiver: SN75ALS175 or the equivalent 220 to 470 16 - 2.4 Wiring for Safety cable (1) Connection Example for input signals The input signals must be redundant. DRIVER For safety function signal connections, the input signal is the 0 V common and the output signal is the source output.
315 385 26 + 0.2 S 745 100 70 23 30 23 25 47 35 335 340 380 450 490 655 43 + 0.2 S 1250 1400 160 105 40 53 40 45 75 60 605 610 670 735 835 1000 55 + 0.2 S 2350 2650 2900 310 130 65 120 65 80 170 115 1100 1100 1100 1200 1400 1750 166 + 0.5 S 3450 4300 4700 560 200 110 140 110 130 220 180 1750 1750 1750 1950 2400 2750 240 + 0.5 S Option Specifications Stroke Adjustment Range of Adjuster
F MXZ12 MXZ16 160 100 OUT side IN side OUT side IN side 140 0.7/ 80 0.7/ Supply pressure [MPa] Supply pressure [MPa] 120 Pressing force [N] Pressing force [N] 100 0.5/0.67 60 0.5/0.67 80 40 0.3/0.4 0.3/0.4 60 40 20 20 0 0 0 20 40 60 80 0 10 20 30 40 Allowable overhang L [mm] Allowable overhang L [mm] MXZ25 MXZ20 400 250 OUT side IN side OUT side IN side 350 0.7/ 0.7/ 200 Supply pressure [
Max 60C / 140F Weight 1.3 kg *Materials in contact with fluid, phosphor bronze/brass E L E C T R I C A L C A P A C I T Y H O W T O O R D E R P N E U M AT I C P R E S S U R E S W I T C H: S E R I E S ISG C O N T A C T S AC amps DC amps Voltage Instantaneous Peak Current Switch Cut-off Current Instantaneous Peak Current Switch Cut-off Current ISG130-031 24 8 3 48 6 1.5 110 30 12 4 0.5 220
, CFM x 102 l/min, CFM x 101 Display unit Note 1, 2) Real-time flow rate Accumulated flow l, ft3 x 101 0 to 50C 5% F.S. or less Operating fluid temperature Linearity Repeatability Temperature characteristics Current consumption (No load) Weight Note 3) 1% F.S. or less 2% F.S. or less 3% F.S. or less (15 to 35C, based on 25C), 5% F.S. or less (0 to 50C, based on 25C) 290 g 150 mA or less 250
(the value under the prescribed conditions) 0.8 0.7 0.6 Subsonic Critical pressure 0.5 0.4 0.45 0.45 Sonic 0.4 0.4 0.35 0.35 0.3 0.3 0.3 0.25 0.2 0.25 0.2 0.2 0.15 0.15 0.1 0.05 0.1 0.1 0.05 S = 0.54 VDW101 10 60 50 40 30 20 10 20 VDW 1.6 S = 1.2 125 100 75 50 S = 3.2 VDW202.3 350 300 250 200 150 100 50 S = 5.8 VDW203.2 600 500 400 300 200 100 S = 2.8 VDW302 300 250 200 150 100 50 VDW303
0.23mm2 R 3 1 P : AC 80 72.5 54.5 M plug connector (M) 56 61 300 (Lead wire) Cover dia 1.5 Cross section 0.23mm2 Indicator light 89 77 78 R 3 1 P : AC Equation L1=16n+11 L2=16n+22 n: Station (Max. 20) Dimensions L n 2 43 54 75 85.5 20 331 342 362.5 373 15 251 262 287.5 298 16 267 278 300 310.5 17 283 294 325 335.5 18 299 310 337.5 348 19 315 326 350 360.5 12 203 214 237.5 248 13 219 230 250
Cylinder (Tube) Inner Diameter(φ): 250, Stroke(mm): 220, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches
9810 2803 OUT 5026 7539 10052 12565 15078 17591 5026 80 25 IN 4535 6802 9070 11337 13605 15872 4535 OUT 7853 11779 15706 19632 23559 27485 7853 100 30 IN 7147 10720 14294 17867 21441 25014 7147 Theoretical output (N) = Pressure (MPa) x Piston area (mm2) Weight Unit: g Male thread additional weight 5 Cylinder stroke (mm) Bore size (mm) 10 15 20 25 30 35 40 45 50 75 100 20 32 40 50 180 200 220