Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 12 10 8 6 4 3.2 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS131FG-M5 AS121FG-M5 M50.8 6, 10, 16, 20 AS231FG-01 AS221FG-01 20, 25, 32 R 1/8 AS231FG-02 AS221FG-02 20, 25, 32, 40 R 1/4 AS331FG-02 AS321FG-02 40, 50, 63 R 1/4 AS331FG-03 AS321FG-03 40, 50, 63 R 3/8 AS431FG-04 AS421FG-04 63, 80, 100 R 1/2
Manifold Specifications for 41 and 42 Type Manifold Specifications for 41 and 42 Type SS5Y5-41 SS5Y5-42 SS5Y7-42 Port size Flow characteristics Model 52-SY740 52-SY540 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) 1,5,3 Model Applicable valve 4,2 (A,B) (P ,EA,EB) b Cv c[dm3/(sbar)] c[dm3/(sbar)] Single base / B mounting Manifold style b Cv SS5Y5-41 1 (SUP) / 3/5 (EXH) Common SUP / Common EXH 1/4
41 AS321FG-02-12 AS321FG-N02-09 69 22 32.8 44.3 20.9 12 15.2 5/16" 48.8 43.8 42.8 37.8 18.5 63 23 31.8 43.3 AS321FG-03-06 AS321FG-N02-11 55 17 27.8 39.3 12.8 6 17.9 3/8" 21 67 27.8 39.3 AS321FG-03-08 AS321FG-N03-07 57 18.5 29.5 41 15.2 8 13.2 1/4" 17 55 R(PT) 3/8 23 41.5 46.5 20.9 19 40.2 35.2 NPT 3/8 19 20.9 29.5 41 AS321FG-03-10 AS321FG-N03-09 59 21 31.8 43.3 18.5 10 15.2 5/16" 46.5 41.5
AS1001FG-04-X12 ASP Ex.) AS1001FG-04-X21 Note) Not particle-free ASN Throttle Valve (Without Check Valve) X214 AQ Ex.) AS1001FG-04-X214 ASV AK Needle Valve/Flow Characteristics VCHC Note) The flow characteristics are representative values.
AS421F-04-10 31.8 47.9 10 17.9 18.5 43.3 21 59 21 100 33.6 3/8" 24 (23.8) 24 (23.8) 1/2 28.6 25.4 57.6 42.1 49.6 50.1 AS421F-04-11 AS421F-04-12 33.6 17.9 48.9 12 47.9 21 20.9 100 22 101 34.6 3/8" 28.6 50.1 42.1 25.4 57.6 49.6 1/2 AS421F-04-13 35.2 21.7 49.5 22 101 Note 1) ( ) are the dimensions of NPT thread.
Auto switch type D-A3, A4 D-G3, K3 D-B5, B6 D-G5, K5 D-A5, A6 D-F5, J5 Cylinder bore size (mm) Bore size (mm) Standard stroke (mm) Long stroke (mm) Model 1800 (1401 or more with tie-rod reinforcing ring) Note 2) 32 25 to 800 32 40 50 63 80 100 32 40 50 63 80 100 32 40 50 63 80 100 BA-32 BA-04 BA-05 BA-06 BA-08 BA-10 BAF-32 BAF-04 BAF-05 BAF-06 BAF-08 BAF-10 BGS1-032 BH2-040 BH2-050 BA-06
41 44 41 41.5 41 41 41 41 41 50 41 52 43 49 83.5 93.5 46.5 43 80 49.5 49 52.5 49 50 49 49.5 49 49.5 49 58 49 58.5 51.5 57.5 92 102 53.5 51 100 56.5 56 61 56 58.5 56 56.5 55.5 57.5 55.5 66 56 66 58.5 68 102.5 112.5 61.5 57.5 Auto switch model D-F5l D-J59 D-F5lW D-J59W D-F5BA D-F59F D-F5NT D-A3lC D-G39C D-K39C D-A44C Bore size Hs Ht Hs Hw Hs Hw 40 38 31.5 73 69 81 69 50 42 35.5 78.5 77 86.5
-04-12SD AS421F-N04-13SD 12 20.9 48.9 22 34.6 Reference dimensions of M5 x 0.8, R threads after installation.
Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 12 10 8 6 4 3.2 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS131FG-M5 AS121FG-M5 M50.8 6, 10, 16, 20 AS231FG-01 AS221FG-01 20, 25, 32 R 1/8 AS231FG-02 AS221FG-02 20, 25, 32, 40 R 1/4 AS331FG-02 AS321FG-02 40, 50, 63 R 1/4 AS331FG-03 AS321FG-03 40, 50, 63 R 3/8 AS431FG-04 AS421FG-04 63, 80, 100 R 1/2
When the ambient temperature is out of the range between the temperatures set for AS.04 and AS.06, AL.03 or AL.04 may be generated at the same time when the product is turned ON.
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
IDG60S to IDG100S IDG3 to IDG50 IDG3H to IDG50H IDG30L, IDG50L Port size Symbol Bore Size V IDG60 to IDG100 IDG60H to IDG100H IDG60L to IDG100L 3 5 10 20 30 50 60 75 100 01 1/8 02 1/4 IDG60S to IDG100S Note) Note) 03 3/8 04 1/2 Note 1) Element service indicator is also available. Refer to Made to Order Specifications on page 14-19-48.
type: White color L type: Black color (Mounting hole) B C D E F G H Model A 3 8 Rc3 8 Rc3 8 Rc3 8 ZH18DS-03-03-03 ZH18DL-03-03-03 ZH20DS-03-04-04 ZH20DL-03-04-04 Rc 133 52.45 42 19 3.5 19 20.95 20.95 133 52.45 42 19 3.5 19 151.1 60.95 47.7 19 3.5 24 26.75 151.1 60.95 47.7 19 3.5 24 26.75 I J K L M N O Model 3 8 Rc3 8 Rc3 8 Rc1 2 Rc1 2 ZH18DS-03-03-03 ZH18DL-03-03-03 ZH20DS-03-04-04 ZH20DL
"), 250 (2-1/2") RCSK-015 RCSK-02 RCSK-03 RCSK-04 RCSK-05 RCDK-015 RCDK-02 RCDK-03 RCDK-04 RCDK-05 Rod Clevis Pin Applicable bore size Including Kit no.