125 to 1000 50 223 97 15 17 120 1/2 38 M27 X 2.0 13 M12 X 1.75 6 20 19 27 60 32 110 136 54 46 52 65 75 95 114 32.5 38 46.5 56.5 72 89 12 16 20 20 25 30 30 35 40 45 45 55 13 13 14 14 20 20 13 14 15.5 16.5 19 19 47 51 58 58 72 72 16 16 16 16 16 16 4 4 5 5 5 5 M6 X 1 M6 X 1 M8 X 1.25 M8 X 1.25 M10 X 1.5 M10 X 1.5 6 6 7 7 10 10 M10 X 1.25 M14 X 1.5 M18 X 1.5 M18 X 1.5 M22 X 1.5 M26 X 1.5 27
RL a 2 0.54~0.66Nm) 1 Ass'y P.27 1 2 L POM,POM,PET,SUS 3 R POM,POM,PET,SUS 4 () (PET) P.27 2 5 Assy PBT P.27 3 6 Assy () P.27 7 7 NBR P.27 4 8 NBR P.27 5 9 Ass'y P.27 6 26 - No.ZQ-OM01401-B 7.4 1 Ass'y2 ) ZQ1-SR1-04-A (1) 01 1 (1) 02 2 08 8 2 () (2 ) ZQ1-SE2-A 3 Assy (2 ) ZQ1-SC1-A 4 (10 ) ZQ-3-005-10AS 5 (10 ) ZQ-3-009-10AS 6 Assy (4 ) ZQ1-WS3-A (1) 3 M3 () (1) 4 M4 ()
27 22 22 13 13 1/4, 3/8 [1 (P), 5 (EA), 3 (EB) port] 25 25 25 25 1/4, 3/8 [1 (P), 5 (EA), 3 (EB) port] 43 43 81 81 3 position closed center/exhaust center/pressure center VFA3 40(-P) 02 03 3 4 5 33 28 1/4, 3/8 [4 (A), 2 (B) port] 13 22 1/8 (Pilot port: Upward) 46 81 1 36 20 4A 2B 26.4 35 42 B A 3EB 1P 5EA 2 x 4.3 (For mounting) 8.5 97 1/8 [Pilot port: Lateral (-P)] 64.5 Breathing hole 27
(M): SYJ7140lMll01 02 01 02 VZS VFS 2-4.3 2-4.3 (Mounting holes) (Mounting holes) VS A B B A 34 27 34 27 B VS7 A A B R2 R1 P R2 R1 P 85.5 [86.8] 81.5 64.3 34 8.5 34 8.5 64.3 (Lead wire length) 300 (Lead wire length) 95.1 300 (P, A, B port) 3-Rc(PT)1/4, 1/8 3-Rc(PT)1/4, 1/8 (P, A, B port) 25.5 41 54 60 71.1 [77.6] 25.5 41 47.6 54 60 [66.5] 11.5 12 20 57.1 20 57.1 11.5 12 (R1, R2 port) 2
3H9 ( ) depth 2.5 +0.025 0 21 M 20 Z ZZ (NN 1) x H G H 5.5 11 11 5.5 B A 3.2 6.5 7 7 12 1 4 NN x M4 x 0.7 thread depth 8 B A 3H9 ( ) depth 2.5 +0.025 0 3H9 ( ) depth 2.5 +0.025 0 HA GA Section AA Section BB (mm) Model F 20 30 20 28 38 ZZ 64 74 84 106 122 M 42 52 62 84 100 Z 41.5 51.5 61.5 83.5 99.5 K 22.5 32.5 42.5 52.5 62.5 J 17 27 40 50 60 I 10 10 7 19 25 NN 2 2 3 3 4 H 25 35 20 30 24
Example: -XA1A24C1C30 -XA2C1C4C30 11-2-27 27 Series CRB2 Axial: Top (Long shaft side) Axial: Bottom (Short shaft side) Symbol: A1 Symbol: A2 The short shaft can be further shortened by machining female threads into it. The long shaft can be further shortened by machining female threads into it. (If shortening the shaft is not required, indicate for dimension Y.)
Example: -XA1A24C1C30 -XA2C1C4C30 11-2-27 27 Series CRB2 Axial: Top (Long shaft side) Axial: Bottom (Short shaft side) Symbol: A1 Symbol: A2 The short shaft can be further shortened by machining female threads into it. The long shaft can be further shortened by machining female threads into it. (If shortening the shaft is not required, indicate for dimension Y.)
Use a tightening torque of approximately 0.10 to 0.20 Nm. 16 18 15 20 23 21 25 25 27 32 27 35 Caution on Proximity Installation Mounting pitch l (mm) When free mounting cylinders equipped with auto switches are used, the auto switches could activate unintentionally if the installed distance is less than the dimensions shown in the table.
Note 2) 2 magnets for auto switches are installed in the housing. 8-26-28 27 Series CXWM Slide Unit: Build-in Shock Absorber Slide Bearing Type 32 Basic Type: CXWM32Stroke/70 to 200 2-M14 x 1.5 Adjusting bolt 2 x 2-6.9 through 2 x 2-11 counterbore depth 6.5 2 positions for set screws 2 x 4-M6 x 1.0 through thread From the opposite side (8H7 hole pitch) for fixing adjusting bolts (M6) 2 x
Terminal (D): 10-SYJ5223-D-M5 M8 connector (WO): 10-SYJ5223-WO-M5 Approx. 300 (Lead wire length) Applicable cable O.D. 3.5 to 7 MAX.10 28.1[35.1] 60.9 53.4 12.7 M8 x 1 32.6 42.1 15.1 39.2[46.2] Approx. 300 (Lead wire length) Pg7 20 20 20 20 107[111.4] 3 3 3 3 87.4[91.8] 105.2 125.2 90.4 77.4 45.4 127 11 11 11 11 23 2-2.6 (For mounting) 2-2.6 (For mounting) 2-2.6 (For mounting) 23 23 23 27
HRS Series 5.10Operation Restoration after Power Failure 5-27 HRX-OM-S004 Chapter 5 Display and setting of various functions 5.10.2 Setting/checking of the operation restoration function The table below shows the setting items of the operation restoration after power failure function and the default setting.
3.1. . 12 3.2 . 13 3.3. . 14 3.4. . 16 (1) . 16 (2) . 16 (3) . 17 4 . 18 4.1 Node Address/Data Rate . 18 4.2 . 19 4.3 DeviceNet . 19 1Step Data Class 67h . 19 2IO Class 68h . 20 3IO . 21 4IO . 21 5 . 23 5.1 PWR . 23 5.2 MOTENC . 23 5.3 SII/O . 23 1 . 23 2 . 24 5.4 DeviceNet . 24 6CN1: . 25 6.1 . 25 6.2 . 25 6.3 . 26 1(C24V,M24V,0V) . 26 2(EMG) . 26 3LK RLS . 26 1 - 6.4 . 27
32 39 18 21 24 27 32 39 24 30 34 40 46 58 92 113.5 116.5 116.5 135 135 47.5 66.5 64.5 60.5 74.5 67.5 62 63.5 76.5 76.5 85 85 17.5 16.5 24.5 20.5 24.5 17.5 25, 50, 75, 100, 125, 150, 175, 200 Nil TN TF P Bore size (mm) PW Q R S T U V X YY YL Z MM ML NN OA OB OL 20 25 32 40 50 63 M5 x 0.8 M6 x 1 M8 x 1.25 M8 x 1.25 M10 x 1.5 M10 x 1.5 Rc1/8 Rc1/8 Rc1/8 Rc1/8 Rc1/4 Rc1/4 17 18 26 27 28.5 30
How to Order Integrated Display Type PF2A7 10 01 27 Flow rate range Thread type Unit specification 1 to 10l/min 5 to 50l/min 10 to 100l/min 20 to 200l/min 50 to 500l/min 10 50 11 21 51 Nil M Wiring specification With unit switching function Fixed SI unit Note) Nil N F Rc NPT G 3m lead wire with connector Without lead wire Nil N Note) Fixed units: Real-time flow rate: l/min Accumulated flow
Set "acceleration time 0 to 3" to use for the acceleration time during positioning. 0: Use the value set in "Pr.9 Acceleration time 0" 1: Use the value set in "Pr.25 Acceleration time 1" 2: Use the value set in "Pr.26 Acceleration time 2" 3: Use the value set in "Pr.27 Acceleration time 3" Da.4 Deceleration time No.
I/O Status Green/Red: ON, Black: OFF Refer to 7.4 Parallel I/O Signals (P.27) for details of the I/O signals. Each output signal can be turned ON and OFF manually regardless of their current status, to check the connection.
Note 2) A R P N.C. 3 port PA N.C. 17-5-5 3 Series LV Manually Operated Series LVH P. 17-5-27 Integral Fitting Type Model LVH20 4 4, 6 1/8, 3/16, 1/4 LVH30 8 6, 8, 10 1/4, 3/8 LVH40 10 10, 12 3/8, 1/2 Orifice diameter Tubing O.D. Metric Inch Symbol Type Valve type Basic type N.C. A B A B Non-locking Locking Manifold (5 stations max.)
) 11(B port) (12.5) Indicator light Indicator light 167 181 59 73 50 90 108 2 4 24.6 38 48 11 (A port) 11 (B port) B A (12.5) (12.5) 14 12 1 5 3 4 2 Manual override 30 45 24.6 A B 25.6 Mounting hole 38 48 B A 14 5 3 1 12 30 45 25.6 Mounting hole Manual override 14.5 27 30.5 32 41.5 91.5 129 G1/2 Electrical entry 79 PE X 41.5 32 30.5 X PE 27 R1 R2 P 15.5 14.5 R1 R2 P 15.5 Rc1/8 External pilot
:Opfion' ,' Note Lead wire with connector zs-27-A Lead wire length: 2m Bracket zs-27-B With mounting screws lM3x5L:2Pcs.) Panel mounl adapter H i s h-p reci s io n D i s *"l?
28.5 27 34 35.5 28.5 29 27 13 8 9.5 4.5 14.5 9.5 6.5 1.5 33 33.5 33 38.5 39.5 34.5 33 33 4.5 0 8.5 3.5 47.5 38.5 14.5 9.5 11 6 16 11 8 3 38.5 38 38.5 43.5 45 38.5 28 37 8.5 3.5 12.5 7.5 54 48 18.5 13.5 15 10 20 15 12 7 48 47 48 52 51 48 46.5 46 8.5 6 12.5 10 66.5 58 18.5 15.5 15 12.5 20 17.5 12 9.5 57.5 59 57.5 62.5 63.5 58 59 57 D-A5/A6/A59W cannot be mounted to 40, 50.