Symbol: FIG (3-Position, Pressure Center), Solenoid: D (Double), Voltage: 1 (100V AC), Option: N (Indicator Light), Port Size: B02 [Bottom Piping 1/4 (R Port 3/8)]
Symbol: FIG (3-Position, Pressure Center), Solenoid: D (Double), Voltage: 3 (24V DC), Option: Z (Indicator Light w/Surge Voltage Suppressor), Port Size: A03 (Side Piping 3/8), Thread: T (NPTF)
Symbol: FIG (3-Position, Pressure Center), Solenoid: D (Double), Voltage: 3 (24V DC), Option: N (Indicator Light), Port Size: A02 [Side Piping 1/4 (R Port 3/8)], Thread: T (NPTF)
Symbol: FIG (3-Position, Pressure Center), Solenoid: D (Double), Voltage: 3 (24V DC), Option: N (Indicator Light), Port Size: A03 (Side Piping 3/8)
Symbol: FIG (3-Position, Pressure Center), Solenoid: D (Double), Voltage: 3 (24V DC), Option: NM (Indicator Light, Direct Manual Override), Port Size: A02 [Side Piping 1/4 (R Port 3/8)]
Symbol: FIG (3-Position, Pressure Center), Solenoid: D (Double), Voltage: 3 (24V DC), Option: NM (Indicator Light, Direct Manual Override), Port Size: A02 [Side Piping 1/4 (R Port 3/8)], Thread: T (NPTF)
Symbol: FIG (3-Position, Pressure Center), Solenoid: D (Double), Voltage: 3 (24V DC), Option: NM (Indicator Light, Direct Manual Override), Port Size: A03 (Side Piping 3/8)
Symbol: FIG (3-Position, Pressure Center), Solenoid: D (Double), Voltage: 3 (24V DC), Option: NM (Indicator Light, Direct Manual Override), Port Size: A03 (Side Piping 3/8), Thread: T (NPTF)
Symbol: FIG (3-Position, Pressure Center), Solenoid: D (Double), Voltage: 3 (24V DC), Option: Z (Indicator Light w/Surge Voltage Suppressor), Port Size: A03 (Side Piping 3/8)
Symbol: FIG (3-Position, Pressure Center), Solenoid: D (Double), Voltage: 3 (24V DC), Option: N (Indicator Light), Port Size: A02 [Side Piping 1/4 (R Port 3/8)]
Symbol: FIG (3-Position, Pressure Center), Solenoid: D (Double), Voltage: 3 (24V DC), Option: N (Indicator Light), Port Size: A03 (Side Piping 3/8), Thread: T (NPTF)
Symbol: FIG (3-Position, Pressure Center), Solenoid: D (Double), Voltage: 1 (100V AC), Option: NM (Indicator Light, Direct Manual Override), Port Size: A03 (Side Piping 3/8), Thread: T (NPTF)
Symbol: FIG (3-Position, Pressure Center), Solenoid: D (Double), Voltage: 3 (24V DC), Option: NM (Indicator Light, Direct Manual Override), Port Size: A03 (Side Piping 3/8)
Symbol: FIG (3-Position, Pressure Center), Solenoid: D (Double), Voltage: 3 (24V DC), Option: NM (Indicator Light, Direct Manual Override), Port Size: A03 (Side Piping 3/8), Thread: T (NPTF)
Symbol: FIG (3-Position, Pressure Center), Solenoid: D (Double), Voltage: 3 (24V DC), Option: Z (Indicator Light w/Surge Voltage Suppressor), Port Size: A03 (Side Piping 3/8)
Symbol: FIG (3-Position, Pressure Center), Solenoid: D (Double), Voltage: 3 (24V DC), Option: N (Indicator Light), Port Size: A03 (Side Piping 3/8), Thread: T (NPTF)
1/4 1 1/4 2.59 1-14 1/2 5/8 3/4 3/4 5/8 3/4 D I M E N S I O N S O V E R S I Z E D R O D S I N G L E D E TA C H A B L E R E A R C L E V I S M O U N T I N G T Y P E NC A1C (XB5) XD BORE (INCH) KK A AA B C D DD E EA EE FA G J M MM P ZD WF CD LR F L LF CB CW Y 6 1/8 5/16-24 200 (2) 1 1/8 2.6 1.5 1/2 2 1/2 0.3 1.26 1.06 1 2.40 6 5/8 1 3/8 3 5/8 2.09 3/4-16 7/8 3/8 3/8 1/2 1/2 5/8 3/8 3/4 3/4 1
Bracket Series MGPL (mm) Standard dimension E st30 30
End boss type Lead wire type In-line Perpendicular L L L Explanatory drawing Auto switch Finger position D-Y59 D-Y7P D-Y69 D-Y7PV D-Y7W D-F9V D-F9WV D-Y7WV D-F9 D-F9BAL D-F9W Model Open Closed Open Closed Open Closed Open Closed Open Closed Open Closed Open Closed Open Closed No setting No setting No setting MHZ2-10 No setting No setting No setting MHZ2-16 No setting MHZ2-20 MHZ2-25 4 8 1
Lead wire: In-line entry Lead wire: Perpendicular entry L L L Unit: mm In-line Perpendicular Lead wire Auto switch Finger position Air gripper D-F9BV D-F9B D-F9NV D-F9N D-F9BA Open 2 7 MHK2-12 Closed 7 3 12 Open 2 6 MHK2-16 Closed 8 1 1 3 13 Open 1 MHK2-20 Closed 5 1 11 Open MHK2-25 Closed 6 2 12 Open 3 MHKL2-12 Closed 3 7 12 Open 1 MHKL2-16 Closed 1 1 3 8 13 Open MHKL2-20 Closed