CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution : WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning : DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Disconnect the jumper wire from the remote terminal A (terminal number 4-5) and connect the switch (A contact: operation signal), and then disconnect the jumper wire from the remote terminal B (terminal number 6-7) and connect the switch (B contact: stop signal). Allow at least 3 minutes before restarting the dryer.
Disconnect the jumper wire from the remote terminal A (terminal number 4-5) and connect the switch (A contact: operation signal), and then disconnect the jumper wire from the remote terminal B (terminal number 6-7) and connect the switch (B contact: stop signal). Allow at least 3 minutes before restarting the dryer.
/N.C. 5 6 24 VDC 12 VDC (B) 2 (A) 4 A SOL.b SOL.a 3 (EB) 5 (EA) 1 (P) Pilot type Nil R Internal pilot External pilot 4 position dual 3 port valve: N.O./N.O. (B) 2 (A) 4 *External pilot specifications is not available for 4 position dual 3 port valves. B SOL.b SOL.a 3 (EB) 5 (EA) 1 (P) 4 position dual 3 port valve: N.C./N.O.
Auto Switch Proper Mounting Position (Detection at Stroke End) D-A93 12 16 to 25 A B W A B W D-M9B/M9N 12 16 to 25 A B W A B W B D-A93 B D-M9B/M9N/M9P Bore size (mm) A 11.5 W 4 A 15.5 W 5.5 12 16 20 25 0.5 4.5 12 0 4.5 16 4 6 16 3.5 1 20 7.5 2.5 17 5.5 -1 21 9.5 0.5 Specific Product Precautions Be sure to read this before handling. Mounting Caution 1.
P11~16 2 CDM2 P14, 3 2./ (mm) 1) (BM2-A)(BJ5-1/) () 2) (BM2-AS/)(BJ4-1/) D-M9A(V) BBA4D-C7/C8/H7 D-H7BA BBA4 BJ2-006BJ2-010BJ2-016 BM2-020(A)BM2-025(A)BM2-032(A) BM2-040(A) BMA2-020(A)BMA2-025(A)BMA2-032(A) BMA2-040(A)BMA2-050(A)BMA2-063(A) BBA4 M3x0.5x14L 1 D-C7C8 D-H7 BHN3-025ABHN3-032ABHN3-040A 11 - <> D-M9NM9PM9BM9NM9PVM9BV D-M9NWM9PWM9BWM9NWM9PWVM9BWV D-M9NAM9PAM9BAM9NAM9PAVM9BAV
CG1 Piping Caution Panel mounting MB q Use a dedicated hose nipple. On the panel mounting style, use the CJ-5H-4 or CJ-5H-6, a dedicated hose nipple (with a fixed restriction) that is provided. If a different fitting must be used due to unavoidable circumstances, make sure to install a speed controller and use it by adjusting it to 500mm/s or less.
JIS B 8370: JIS B 8361: JIS B 9960-1: -(1 :) JIS B 8433-1993: *2 : : : 1, 2 3 1 2 3 4 -3No.EX-OMN0035CN-A / 1 1.5 *3) *3) 1 1 () -4No.EX-OMN0035CN-A () () () () -5No.EX-OMN0035CN-A /, , () * UL UL1310 Class2 0V -6No.EX-OMN0035CN-A * IP67 / *() ,, SI SI SI * IP67 M12M8 () -7No.EX-OMN0035CN-A CE , * 20-23 PLC PLC * -8No.EX-OMN0035CN-A , SI 1 SI 32 10 SI SI ON/OFF PNP
The fluid in pump chamber A is forced out to the discharge port, and the fluid is sucked into pump Air supply (AIR SUP) 5 port solenoid valves P2 P1 Discharge port (FLUID OUT) Pump chamber A Pump chamber B Check valve Shaft Suction port (FLUID IN) Diaphragm A Diaphragm B Drive chamber A Drive chamber B chamber B from the suction port. 4.
, resin plug, reducer, etc. after connecting a fitting with a metal rod (KC series, etc.) to a One-touch fitting.
A Applicable motor B Nothing included.
A B PSE57-01 8 R1/8 PSE57-02 12 R1/4 Lead wire and M12 connector ZS-37-A ZS-37-B -17No.PS-OMS0005-E Adapter with throttle ZS-31-X Model No. D E F G H I ZS-31-X188 20 9 R1/8 Rc1/8 14 1.5 ZS-31-X175 29 13 R1/4 Rc1/4 17 1.6 -18No.PS-OMS0005-E Revision history A: Contents are added. B: Contents are added. C: Contents revised in several places. D: Contents revised in several places.
How to Calculate the Set Value A = Max. pressure value in auto preset mode B = Tentative min. pressure value in auto preset mode P1 = A (A B)/4 P2 = B + (A B)/4 Manual adjustment is possible after finishing in the auto preset mode.
(or within 3 kPa ) 1/8 ARP ARP 1/4 For 0.2 MPa setting With backflow function (ARP20K/30K/40K) 3/8 IR-A 1/2 Installable between a solenoid valve and a cylinder : Standard : Semi-standard IR Direct operated precision regulator now available as a series!! (ARP20/30/40) IRV VEX SRH Applications Applications SRP a Apply a constant pressure to fluid. b Adjust the blow-line pressure.
Use the tip of the watchmakers flat blade screw driver to insert the clip to the end properly. 1) Insert a watchmakers flat blade screw driver along with taper of hole B on OUT side of the body. 2) Hook the tip of the screw driver to the inserted clip, and pull out the clip. As the clip may fly out, pull it slowly as holding it with a hand. 3) Pull out the mounted One-touch fitting.
VE System A System B START VY RUN START G AL Analog voltage input 0 to 10V PLC START Robot support (External input operation) RUN START After both systems A and B have been auto balanced, an operation command is input to the controller to operate the cylinder. At the point at which the auto switch for stopping has been tripped, systems A and B are stopped to assemble parts.
Use the tip of the watchmakers flat blade screw driver to insert the clip to the end properly. 1) Insert a watchmakers flat blade screw driver along with taper of hole B on OUT side of the body. 2) Hook the tip of the screw driver to the inserted clip, and pull out the clip. As the clip may fly out, pull it slowly as holding it with a hand. 3) Pull out the mounted One-touch fitting.
(or within 3 kPa ) 1/8 ARP ARP 1/4 For 0.2 MPa setting With backflow function (ARP20K/30K/40K) 3/8 IR 1/2 Installable between a solenoid valve and a cylinder : Standard : Semi-standard IRV Direct operated precision regulator now available as a series!! (ARP20/30/40) VEX SRH SRP Applications Applications SRF a Apply a constant pressure to fluid. b Adjust the blow-line pressure.
B) In the state of A), attach the workpiece and the arm side block, and adjust the shim so that there is a space of about 0 mm. During this step, theoretically, there is no clamping force pressing down on the workpiece. C) In order to generate a clamping force from the state described in step B), insert an additional shim.
LXPB2SB-B LXPB5SA-B LXPB2BC-B LXPB5BC-B LXPB2BD-B LXPB5BD-B LXPB2SA-B 5 phase to 200 2 phase to 200 5 phase to 100 2 phase to 30 5 phase to 30 2 phase to 80 5 phase to 80 2 phase to 100 Sanyo Denki Co., Ltd. 5 phase to 200 2 phase to 200 5 phase to 100 2 phase to 30 5 phase to 30 2 phase to 80 5 phase to 80 2 phase to 100 LXSH5SB LXSH2SB LXSH5SA LXSH2SA LXSH5BC LXSH2BC LXSH5BD LXSH2BD LXSH5SB-B