[cm] -70No.PF-OMS0001CN-A PFMC7501/7102/7202 2x A B D E F H K L N PFMC7501/7102 Rc1/2NPT1/2 70 30 60.6 41.2 15 14 26 18 13.6 PFMC7202 Rc3/4NPT3/4G3/4 90 35 66.1 46.7 17.5 24 31 28 16.8 PFMC7501/7102 G1/2 76 30 60.6 41.2 15 14 26 18 13.6 S T U V W PFMC7501/7102 24 22 32 40 50 PFMC7202 30 30 42 48 58 -71No.PF-OMS0001CN-A M8 (ZS-40-A) -72No.PF-OMS0001CN-A Revision history A [September 2016]
P Part in contact with fluid A part that comes into physical contact with the fluid. Pressure characteristics The amount of variation in the analogue output or display value when the supply pressure is changed.
NPN output Number of outputs The number of points that can operate output device (solenoid valve) P PLC Abbreviation of programmable logic controller. A digital computer used for automation of electromechanical processes. The output type that uses a PNP transistor to operate output device.
AK ASS ASR ASF 15-9-11 3 Series AS Construction Component Parts No. q w e r t y u i o !0 !
P-80 (N) This catalog is printed on recycled paper with concern for the global environment.
L With surge voltage suppressor H 100 VAC J 110 VAC K 200 VAC L 230 VAC M Conduit terminal 24 VDC With surge voltage suppressor N 100 VAC P 110 VAC Q 200 VAC R 230 VAC S Conduit 24 VDC With surge voltage suppressor T 100 VAC U 110 VAC V 200 VAC W 230 VAC Faston terminal Y 24 VDC Z Other voltages For other special options, refer to pages 20 and 21. 24 VAC 48 VAC 220 VAC 240 VAC 12 VDC Special
Refer to front matters 58 and 59 for Safety Instructions and pages 687 to 691 for Pressure Switch Precautions. q w Locking nut t Wiring Warning e 1. Since the light emitting diode (LED) is used for the light assembly for 24 VDC, there are 2 terminals and polarity. One is + for red load wire and the other is for black load wire. Light will not light up if wired incorrectly. 2.
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 2, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 3, Cable Option: T (Centralized Lead Wired, w/Bracket)
Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 4, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 2, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 6, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 3, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 4, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 6, Cable Option: T (Centralized Lead Wired, w/Bracket)
Series: 5 (VFA5000), Actuation: 5 (3 Position Pressure Center), Body: 20, A, B Port Size: 03 (3/8), Thread: T (NPTF), Bracket: w/o Bracket, Pilot Port Direction: P (Lateral)
Series: 5 (VFA5000), Actuation: 3 (3 Position Closed Center), Body: 20, A, B Port Size: 03 (3/8), Thread: T (NPTF), Bracket: w/o Bracket, Pilot Port Direction: P (Lateral)
Series: 5 (VFA5000), Actuation: 3 (3 Position Closed Center), Body: 20, A, B Port Size: 02 (1/4), Thread: T (NPTF), Bracket: w/o Bracket, Pilot Port Direction: P (Lateral)
Series: 5 (VFA5000), Actuation: 4 (3 Position Exhaust Center), Body: 20, A, B Port Size: 02 (1/4), Thread: T (NPTF), Bracket: w/o Bracket, Pilot Port Direction: P (Lateral)
Series: 5 (VFA5000), Actuation: 5 (3 Position Pressure Center), Body: 20, A, B Port Size: 02 (1/4), Thread: T (NPTF), Bracket: w/o Bracket, Pilot Port Direction: P (Lateral)