F F Fn n n n (KF) () Heater (option) Auto switch H H H H J J J J G G G G B B B B A A A A A A A A Model A B C D E Fn G H J K XLC-25 50 120 48 1 12 40 26 39 27.5 8 XLC-40 65 171 66 2 11 55 41 63 36 9 8 XL-OMO0001-A 5 Guaranteed period and range The warranty period is 2 million cycles (under SMC endurance test conditions), 18 months after delivery or 12 months in service, whichever comes first
XGT 3 1 2 50336 1 C O 1:FKM 2:Kalrez R 4079 Kalrez R DuPont Performance Elastomers 50336 50mm 336mm 2: 3: 1:1 3:300mm A :0.5m D-A93 C 6 (C016 30C006 100 12:AMP ) (2 ) F 9 D CDE-9PF05 5 - 3. 6 - 3-1 1AB 23 2 3 19 2A 21 23 2B 1B 2C 2 2 3 19 3-2 1A 1B 26 8 9 22 13 12 18 9 27 12 13 18 9 18 , 21O 5 6 7 ASSY O 4 3-3 2A2B CLOSEOPEN 8 9 9 13 12 18
ExIP8001-010-EW F With feedback lever unit for stroke 50 to 140mm. 2: When 52ATEX type specify symbol M, 2, 5, blue cable grant is equipped for electric connection. W With body cover window.
c. 6. 1. 7. a.060 b.2585%RH c. d. e. 8. ,, f. g.( 9. ) h. i. j. k. l. 2. 1. 2. 1. 3 2. 1. 3. 4. 1. 12:0.071.0MPa 2063:0.051.0MPa :060 5. 2. 1. 5m 1. 2. 2. 3. F.G. 4. 1. 1. 2. 12 10N [102kgfcm] 1. 2032 20N [204kgfcm] () 40,50,63 30N [306kgfcm] 2. 3. 2. 1.52 1. 2. 1. 1()ISO VG32 3. 4. 5. 6. 1. 2.14.5mT CE1 3. 4. (DC1224V) [] 1. 2. 3. 4. 2.
Place where atmosphere containing con-ductive powder such as dust and iron chips, oil mist, salt, or organic solvent, or splashing cutting chips, dust and cutting oil (water , liquid) over the products. f. Place where the products are exposed to direct sunlight or radiated heat. g.
Template DKP50047-F-085D Avoid repeating sudden charges and discharges of the air tank. These may cause the temperature of the product the exceed the maximum allowable value. Danger Do not exceed any of the specifications listed on the label, in section 2 of this document or on the customer drawing. Air equipment has air leakage as standard within certain limits.
e c t i o n P e r i o d i c i n s p e c t i o n D i sassem ble and reassem bl e C a u t i o n o f d i s a s s e m b l e D i s a s s e m b l i n g p r o c e d u r e A s s e m b l e p r o c e d u r e T r o u bl e s hoo t i n g Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Move Speed Position Accel PushingF T riggerL V PushingSp Moving F Area1 Area2 In posn mm/s2 mm/s mm mm/s2 mm/s mm mm mm 0 Absolute 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 Absolute 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 Absolute 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 6.
. -7No.PS-OME0004-G Model Indication and how to order Option Description Part number Remarks Connector for pressure sensor controller ZS-28-C 1 pc. per set Sensor cable ZS-26-F Cable length: 3 m Cable length: 3 m The connector is not connected to the cable at the time of shipment Connector for pressure sensor controller + Sensor cable ZS-26-J Definition and terminology Terms Meaning F Abbreviation
Option/Semi-standard symbol : When more than one specification is inqures, indicate in alphanumeric order. 3 4 5 6 2 1 Symbol Description 0 0.01 to 0.2MPa 1 0.01 to 0.4MPa Set pressure range 2 0.01 to 0.8MPa + 0 Bottom exhaust 1 Front exhaust Exhaust direction 2 Back exhaust + Nil Rc N NPT Thread type F G + 02 1/4 03 3/8 Port size 04 1/2 + Nil Without mounting accessories B With bracket
Object instance Present value of maintenance counter 0 to 4294967295 (0 to F H) 0x66 Maintenance Counter Maintenance counter threshold over flag 0: Maintenance counter 0x67 Maintenance Counter Exceed value < Threshold 1: Maintenance counter value > Threshold Threshold of maintenance counter 0 to 4294967295 (0 to F H) The set value is immediately reflected. 0x68 Threshold Maintenance Counter
(f) Input the step data No. 2 (INx). (g) Turn the "DRIVE" input ON. Step data No. 2 (OUTx output) will be output. (h) The AREA output will turn OFF. The BUSY output will turn ON and INP output will turn OFF. (The positioning operation will start). (i) The AREA output for step data No.2 will turnON (at 170mm from the origin point).
F: Contents revised in several places. G: Contents revised in several places. Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2009-2015 SMC Corporation All Rights Reserved No.EX-OMI0032-G
Nozzle diaphragm assembly Aluminum, Weather resistant NBR Seal HNBR Seal NBR Diaphragm spacer Polyacetal Supply diaphragm Weather resistant NBR Exhaust diaphragm assembly Aluminum, Weather resistant NBR Valve assembly Aluminum, stainless steel, HNBR Body Aluminum die-cast Grease: lithium grease -7- How to order IR 0 0 01 BG A 0 1 Option/Semi-standard: Select one each for 'a' to 'f'
( di spl ayed al t ernat el y) Press Skey f or 2 seconds or m ore, t hen go out f rom det ai l set t i ng m ode. ( Sel ect t he m enu w i t h or keys, t hen j um p t o anot her i t em . ) Lock keys ( ref er t o P9) Rel at i on bet w een set t i ng and sensi t i vi t y Sensi t i vi t y Sharp D ul l Set t i ng of sensi t i vi t y D ef aul t : 13 - Zero clear The display can be reset to
Series 10-MGF Guide table 40, 63, 100 How to Order 10 M G F 63 50 Y59B Number of auto switches 2 pcs. 1 pc. 10 Clean series Relief type Nil S Bore size (mm) Reed switch Type of auto switch Port type Z73 Solid state switch Y59A,Y59B Bore size Type Rc NPT G Symbol Nil TN TF 40, 63, 100 Cylinder stroke (mm) Model Cushion Bore size (mm) 40 63 100 Standard stroke (mm) Auto switch mounting Action
f 12 3.3 5.8 2.6 1.6 4.8 16 3.7 6.2 3 2.5 6.5 20 5.4 8.4 4.5 2.8 7.8 25 5.4 8.4 4.5 3 8.2 12 7 16 2.5 20 8.5 25 6 50 mm stroke or less Top-ported type The use of a slot (width XA, length XB, depth 3) allows for a relaxed pin pitch tolerance, with the pin hole (XAH9, depth 6) as the reference, without affecting mounting accuracy.
(N) F Stroke (mm) Bore size (mm) Model 25 50 75 100 125 150 175 200 DMGTM 140 151 162 176 193 212 178 204 63 MGTL 199 212 226 243 170 186 127 143 -X F MGTM 199 213 228 246 267 291 221 250 80 Individual -X MGTL 180 192 205 220 237 255 154 62 MGTM 271 288 307 328 353 382 321 356 100 MGTL 242 257 274 292 313 335 153 114 453 Series MGT Construction o !
Nil S n Bearing type Slide bearing Ball bushing bearing M L Mounting style Auto switch Basic style Front mounting flange style Nil Without auto switch (Built-in magnet) B F For the applicable auto switch model, refer to the table below.
Arm opening angle 30, 45, 60, 90, 105, 120, 135 Switch TURCK/P&F Both TURCK and P&F switches are available. Port thread NPT/G Reduces the effects of impact from unclamping the cylinder. Arm Variation Prevents the infiltration of spatter, dust and other contaminants.