This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA (N.C), VALVE, VXD/VXZ 2-WAY MEDIA VALVE, 1A, VXD/VXZ OTHER SIZE RATING, 3.13056 lb, ModelBody sizePort size (Thread)10A15A20A25AVXD2260???--1
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA (N.O), VALVE, VXD/VXZ 2-WAY MEDIA VALVE, 1B, VXD/VXZ OTHER SIZE RATING, 3.30693 lb, PortsizeOrifice size (mm?)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA (N.O), VALVE, VXD/VXZ 2-WAY MEDIA VALVE, KB, VXD/VXZ BODY PT >3/4NPT, 3.51269 lb, Port size (Nominal size)Orifice size (mm?)
along with the manifold base model no. 5(R) 1 (P) (R)3 3(R) 1 (P) 3 position exhaust center 3 position exhaust center 4(A) (B)2 4(A) (B)2 (Example) SS5YJA3-41-03-M5 1 pc.
Precision Regulator IR1000-A/2000-A/3000-A Series How to Order 0 0 0 IR 1 01 BG r t y u e w q A ARJ Option/Semi-standard: Select one each for a to e. Option/Semi-standard symbol: When more than one specication is required, indicate in alphanumeric order.
Regulator IR1200-A/2200-A/3200-A Series How to Order 0 2 0 IR 1 01 BG r t y u e w q A ARJ Option/Semi-standard: Select one each for a to e. Option/Semi-standard symbol: When more than one specication is required, indicate in alphanumeric order.
To install/remove the Flow Control Equipment, tighten/loosen at wrench flat B as close to the thread as possible using the appropriate wrench. Do not apply torque at other points as the product may be damaged. Rotate Body A manually for positioning after installation. 1. Check that the lock nut is tightened. A loose lock nut may cause actuator speed changes. 2.
Weight g 65 65 25 15 15 B side traveling parallelism to A side Refer to Graph 1.
The cylinder should be operated using a connection method which allows for shaft alignment variations and deflection due to the cylinder's own weight. A drawing of a recommended mounting method is shown in Figure 1.
To install/remove the Flow Control Equipment, tighten/loosen at wrench flat B as close to the thread as possible using the appropriate wrench. Do not apply torque at other points as the product may be damaged. Rotate Body A manually for positioning after installation. 1. Check that the lock nut is tightened. A loose lock nut may cause actuator speed changes. 2.
During regular maintenance, check for the following and replace any components as necessary. a) Scratches, gouges, abrasion, corrosion b) Leakage c) Flattening or distortion of tubing d) Hardening, deterioration or softness of tubing IN2 OUT A port 1687
hole F Applicable screw M5 hexagon socket head cap screw M6 hexagon socket head cap screw M8 hexagon socket head cap screw Model AMP220 AMP320 AMP420 E OUT Maintenance space (mm) C B Bracket related dimensions Element service indicator related dimensions Port size (nominal size B) Model A D E I 66 80 90 J K L M N O P Q R S F 80 120 180 G 123 169 237 H AMP220 AMP320 AMP420 76 90 106 76 90
To install/remove the Flow Control Equipment, tighten/loosen at wrench flat B as close to the thread as possible using the appropriate wrench. Do not apply torque at other points as the product may be damaged. Rotate Body A manually for positioning after installation. 1. Check that the lock nut is tightened. A loose lock nut may cause actuator speed changes. 2.
hole F Applicable screw M5 hexagon socket head cap screw M6 hexagon socket head cap screw M8 hexagon socket head cap screw Model AMP220 AMP320 AMP420 E OUT Maintenance space (mm) C B Bracket related dimensions Element service indicator related dimensions Port size (nominal size B) Model A D E I 66 80 90 J K L M N O P Q R S F 80 120 180 G 123 169 237 H AMP220 AMP320 AMP420 76 90 106 76 90
B) In the state of A), attach the workpiece and the arm side block, and adjust the shim so that there is a space of about 0 mm. During this step, theoretically, there is no clamping force pressing down on the workpiece. C) In order to generate a clamping force from the state described in step B), insert an additional shim.
In order to prevent a malfunction or diaphragm damage caused by debris or cutting chips in the fluid, install a filter with approximately 100 mesh on the inlet side of a flow switch. C (COM) A (N.O.) Color of lead wire Black Symbol Contact C Z I SE3 Common A White Normally Open B (N.C.)
RB08-X331 RB10-X331 RB14-X331 RB20-X331 RB27-X331 RJ08 RJ10 RJ14 RJ2015 Replacement parts for a type with cap. Cannot be mounted on basic type. RJ2725 Material: Polyurethane Dimensions Part no. A Applicable absorber B SR Dimensions RBC08C RBC10C RBC14C RBC20C RBC27C RJ08U 6.5 6.8 6 RJ10U 9 8.7 7.5 X RJ14U 12.5 12 10 16 18 20 RJ2015U 21 25 25 RJ2725U H B T 2 x D MM L Part no.
IP8000-011-AG) Note 3) A is applied to approx 90cm3-capacity actuator. B is applied to approx 180cm3-capacity actuator. Note 4) Standard lever is not attached. Note 5) It is to be used together with A or B when tending to overshoot by the use of A or B. It is mounted to the body as a replacement of the standard compensation spring. Note 6) With terminal box, Non-explosion proof.
Spare Parts List 290301 Diaphragm Assy NBR 1 Part number Part name Material Quantity 29038 Diaphragm NBR 1 29063#1 Valve NBR 1 JIS B 2401, P3 O ring NBR 2 JIS B 2401, P7 O ring NBR 1 JIS B 2401, P10 O ring NBR 1 JIS B 2401, P34 O ring NBR 1 -9- #1 -9-10-10- Revision A Format change and content review B Drawing update 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249