SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ7-40-15-01T"

.* * This time can be shortened as described below. 1) Provide a valve on the outlet side of the membrane air dryer. 2) Supply air with the valve closed so that only purge air flows through the membrane air dryer. 3) After 15 minutes or more, open the valve and let air flow to the outlet side equipment. Selection Caution a. Do not obstruct the purge air discharge ports.

Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 95 Mechanically Jointed Rodless Cylinder/Linear Guide Type Series MY1H-Z 25, 32, 40 Construction With End Lock: 25 to 40 !2 i !4 o The numbers are the same as the "Construction" of the MY1H series catalog (CAT.ES20-221). *BLUE links will lead to purchase pages. Call or email us at sales@smcpneumatics.com for request.

Seal kit includes a grease pack (40, 50: 10 g, 63, 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 15 is a non-replaceable part, so it is not included in the seal kit. 36

FN11V FPM KT-FN11V 7 Low Maintenance Filter Series FN1 Dimensions Rc 1/4 0 315 45 IN OUT B.C.D230 135 225 42 4-11 G46-15-02 Pressure gauge port size Rc 1/4 Note) Use the Pc 1/4 port marked with an asterisk when designing an air release circuit.

Prassuro 1s0 PSIG (9.9 Kgflcm ) Prool Pr333ure 225 PSIG (15 Kgr cm ) Amblnl Temp. 40 120"F (5 50"C) Responsg Tlme 30 ms Max. 50 ms Max. 30 ms Max. 50 ms Max, Hysteresls 3% F.S. Repeatablllty 3/. Sensitivity o.5/.

Seal kit includes a grease pack (40, 50: 10 g, 63, 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 15 is a non-replaceable part, so it is not included in the seal kit. 36

Min. 207 Panel 54 72.5 10 69.5 2 R1/8 74 40 7 30 OUT OUT IN 2 x M6 depth 10 2 x Rc1/4 Pressure gauge port Rc1/8 78 70 A 160

Weight (g) L1 M Width across flats H1 H2 Nozzle size D Model KN-04-100 KN-04-150 KN-06-100 KN-06-150 KN-06-200 KN-08-150 KN-08-200 KN-10-250 KN-10-300 KN-10-350 KN-10-400 KN-10-600 KN-12-350 KN-12-400 KN-12-600 KN-16-400 KN-16-600 KN-20-400 KN-20-600 13 14 19 20 22 28 30 35 36 37 30 28 54 55 40 77 79 117 112 15 15 16 16 16 16 16 17 17 17 17 17 17 17 17 17 17 17 17 27 27.7 30.1 30.8 31.5 33.8

For standard installation, turn 15 to 30 using tool, after fastening by hand. Pay attention not to over torque the product.

Replacement Parts: Seal Kit (15, 16, 35 and 39 are not included in the seal kit. Order them as required with by individual part numbers.) Description Qty. MY1H16 No.

Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 95 Mechanically Jointed Rodless Cylinder/Linear Guide Type Series MY1H-Z 25, 32, 40 Construction With End Lock: 25 to 40 !2 i !4 o The numbers are the same as the "Construction" of the MY1H series catalog (CAT.ES20-221). *BLUE links will lead to purchase pages. Call or email us at sales@smcpneumatics.com for request.

FSC() FSt FSt FStFSt 1 digit 15 2CH1 CH2CH3CH4 CH1 OUT1 CH2CH3CH4 CH1 CH2CH3CH4 OUT1 CH1 OUT1 CPy CPy CPy CPy 1 digit -24No.PS-OMH0005CN-D 26 SH1 CH1onoF SH1 ON OFF CH2 CH3 CH4 12 -25No.PS-OMH0005CN-D 10 ms oooC_5C_3 CH1 OUT1OUT2 P_1 P_4n_1 n_4C_5 CH2CH4 OUT1 P_1 P_2n_1 n_2C_3 15 ms oF oFLo() ooo () EEPROM Aon ((PSE530 ) (PSE530 ) (PSE530 ) -26No.PS-OMH0005CN-D

The configurable parameter and how to set them when via Webserver of Air Management System, please refer to the operation manual of Air Management System/Air management Hub AMS20/30/40/60EXA1(PF-OMA1007-, pages 51 and 122).

Warning Warning -15- This operation manual is for rack pinion type Rotary actuator with Solenoid Valve. Cautions will be given on the load (inertia moment), rotation time and others. Please read through the manual before starting operation.

:GR-S-010(10g):GR-L-005(5g) 14 3-3. 2 (MHF2-8D2MHF2-12D20D) 1. 2. 8:12:R 1620:C ABC 3. (8:) (12 ) :GR-S-010(10g):GR-L-005(5g)GR-L-010(10g) 8 2 12 2.5 16 3 20 4 B C C 8 A 12 0.9 16 C MHF2-8D2 20 1.3 MHF2-12D* R MHF2-8D2 8 1.5 12 2 16 2.5 20 3 12 15 3-4. /1 MHF2-8DMHF2-8D1 1 16 2 17 3 18 4 19 5 20 NBR 6 21 NBR 7 8 A 9 B 10 C 11 12 13 14 15 MHF2-8D

Use a protective cover. 15 FG Do not mount the product in a location where it is subject to strong 3.5 Model number of product vibrations and/or shock.

An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. 15 Series KK/KK13 Common Precautions 1 Be sure to read before handling. Mounting Selection Warning Caution 1. Before mounting confirm the model and size, etc. Also, confirm that there are no blemishes, nicks or cracks in the product. 2.

Indicator light IS 3 2 Lead wire R 1/8 Port size ZSM 65 g Weight PF2 IF Electrical Specifications Data ZSM1-115 Supply voltage 4.5 to 28 VDC Output (Open collector) 30 V, Max. 100 mA Current consumption 10 mA or less (24 VDC) ZSM1-121 Supply voltage 100 VAC Operating current range 24 V or less: 50 mA, 48 V: 40 mA, 100 V: 20 mA Max. contact capacity AC 2 VA, 2 W DC How to Order ZSM1 1 15 Lead

Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.