Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Output Specification: RT (Switch output 1 + Switch output 2 + Analog voltage output), Units specification: w/Units Selection Function, Piping Specification: 01 (R 1/8), Option 1: W (Lead Wire w/Connector, 2m Waterproof), Option 2: None, Option 3: Y (w/o Operation Manual)
Output Specification: L2 (IO-Link/Switch output 1 + Switch output 2), Units specification: w/Units Selection Function, Piping Specification: 01 (R 1/8), Option 1: W (Lead Wire w/Connector, 2m Waterproof), Option 2: None, Option 3: Y (w/o Operation Manual)
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: w/o Operation Manual, w/o Calibration Certificate
Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: w/o Operation Manual, w/o Calibration Certificate
Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: w/o Operation Manual, w/o Calibration Certificate
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: None, Operation Manual: w/o Operation Manual, w/o Calibration Certificate
Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: None, Operation Manual: w/o Operation Manual, w/o Calibration Certificate
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3-Screen High Precision Dig Press Switch, PRESSURE SWITCH, ISE1-6, 51 lb
() 10 m DC(-)() () -7No.PF-OMO0007CN * ( ) () CE 050 -8No.PF-OMO0007CN * ON , 10 /23 3 OFF (19 ) * OUT -9No.PF-OMO0007CN (11 ) SI L/min L (11 ) 1/8 1/4 3/8 1/2 -10No.PF-OMO0007CN N (3 m) PF2A7--28--X560 NPN(1 )+ (15 V) PF2A7--29--X560 NPN(1 )+ (420 mA) 22 PF2A7--68--X560 PNP(1 )+ (15 V) PF2A7--69--X560 PNP(1 )+ (420 mA) / ZS-37-A () 3 m 100 g ZS-37-B (L ) 3 m 100 g ZS-29-T
Feb P QP RP SP . ZP AP BP . May S QS RS SS . ZS AS BS . Aug V QV RV SV . ZV AV BV . Jan o Qo Ro So . Zo Ao Bo . Nov y Qy Ry Sy . Zy Ay By . 2012 2013 2014 . 2021 2022 2023 . Year Jun T QT RT ST . ZT AT BT . Dec Z Qz RZ SZ . ZZ AZ BZ . Apr R QR RR SR . ZR AR BR . Jul U QU RU SU . ZU AU BU . Month Q R S . Z A B . Oct X QX RX SX . ZX AX BX .
(b) Incorrect mounting of V band (Not correctly fit with collar of cover V band for replacement Part no Retainer T bracket Clamping position check pin Clamping nut Latch Fig. (c ) V band tightening 6 Restart and air discharge When restart the operation after the replacement of the element, follow the procedure of section 4 Operation.
Year Month 2015 2016 2017 2025 2026 2027 T U V D E F Bore Size (mm) Torque 10% (N.m) Jan O TO UO VO DO EO FO Instruction Manual CG1*N25&100-*Z-X2992 Air Reservoir 32 2.9 Feb P TP UP VP DP EP FP 40 4.9 Mar Q TQ UQ VQ DQ EQ FQ 50 11.8 Apr R TR UR VR DR ER FR 63, 80 24.5 Do not service or attempt to remove product and May S TS US VS DS ES FS machinery/equipment until safety
Select Nil, S, or T for DeviceNetTM or CC-Link. Select Nil, 1, 3, or 5 for parallel input. 5 -
Caution Actuator and controller are sold as a set. When purchasing without controller, make sure that the combination of actuator and controller is correct.
Specification 1.1 AC servo motor 1.1.1 How to order L E J S 100 T9 B 500 T X400 Lead [mm] Motor type Stroke [mm] H 50 200 200 T9 AC servo motor to to A 25 1500 1500 B 10 *Refer to the applicable stroke table.
P. 12-6-17 12-6-5 5 Series MHK2 Construction Double acting Single acting @0 e !8 !7 w o Open condition Normally open !9 t y !5 !6 i u q r !1 !0 Closed condition Normally closed !2 !3 !4 Component Parts Material Material Note Note No. q w e No. i o !0 !1 !2 !3 !4 !
9 u t MDHR3 !4 !3 q !1 @0 @1 w o e i !5 MHZ MHF r !7 !6 t !8 !0 !2 i !9 y u MHL Component Parts MHR MHR Description Material Description Material Note No. Note No.
Refer to p.0-39 to 0-46 for Safety Instructions and common precautions. CM2 C85 Construction (Disassembly is not possible.) CG1 Piping Caution Panel mounting MB q Use a dedicated hose nipple. On the panel mounting style, use the CJ-5H-4 or CJ-5H-6, a dedicated hose nipple (with a fixed restriction) that is provided.
Description Material Note q Electroless nickel plated Brass Body B w Electroless nickel plated Brass Body A e Electroless nickel plated Brass Needle r Electroless nickel plated Brass Lock nut t Electroless nickel plated Brass Handle y HNBR U seal u Electroless nickel plated Brass Needle guide i NBR O-ring o NBR O-ring !0 Chromium bearing steel Steel ball !
P. 12-6-17 12-6-5 5 Series MHK2 Construction Double acting Single acting @0 e !8 !7 w o Open condition Normally open !9 t y !5 !6 i u q r !1 !0 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Closed condition Normally closed !2 !3 !