A1 L1 R1 U1 NDH10 U(H8) E1 MM NX Applicable bore size (mm) Applicable bore size (mm) I-02 I-03 I-04 IA-04 Part no.
m 160 m 100 m Lower level bus Number of branches for input/output 4 branches for input, 4 branches for output Communication type Communication protocol: dedicated for SMC Communication speed: 750 kbps Current for input branch Max. 1 A per branch Current for output branch Max. 1.5 A per branch Branch cable length Within 20 m (See diagram right for details.) : Maximum value in total of current
(Value in the initial stage) Base mounted Body ported Model Flow characteristics (2) Pilot port piping location b Cv b Cv Port size Rc 14/2(PA/B) 4/25/3(A/BEA/EB) Pilot port size Valve model Function Single Double Closed center Exhaust center VZA4121-01 VZA4221-01 VZA4321-01 VZA4421-01 VZA4141-1-01 VZA4141-1-02 VZA4141-2-01 VZA4141-2-02 VZA4241-1-01 VZA4241-1-02 VZA4241-2-01 VZA4241-2-02
VFRA3111-03 VFRA3211-02 VFRA3211-03 VFRA3311-02 VFRA3311-03 VFRA3411-02 VFRA3411-03 VFRA3511-02 VFRA3511-03 1/4 3/8 1/4 3/8 1/4 3/8 1/4 3/8 1/4 3/8 0.38 0.39 0.41 0.36 0.40 0.39 0.42 0.42 0.33 (0.48) 0.34 (0.47) 1.9 2.2 1.9 2.0 1.8 1.9 1.7 1.8 1.9 (0.69) 2.2 (0.69) 0.61 Single 1/8 2 position 0.71 Double 1/8 Body ported Closed center 0.72 1/8 Exhaust center 0.72 1/8 3 position Pressure center
VZA4141-2-01 VZA4141-2-02 VZA4241-1-01 VZA4241-1-02 VZA4241-2-01 VZA4241-2-02 VZA4341-1-01 VZA4341-1-02 VZA4341-2-01 VZA4341-2-01 VZA4441-1-01 VZA4441-1-02 VZA4441-2-01 VZA4441-2-02 Single Double Closed center Exhaust center 0.44 0.44 0.44 0.44 0.25 0.25 0.25 0.25 1.7 1.7 1.7 1.7 0.49 0.49 0.47 0.47 0.14 0.14 0.15 0.15 2.0 2.0 1.9 1.9 Body ported Base mounted (With sub-plate) 2 position
Tubing size (O.D. x I.D.) mm: 12 x 9 IDG30 IDG50 0 m 20 1 m 19 3 m 17 5 m 16 Note) In cases other than above model numbers, if the tube length is 5 m or less, an increase of the outlet air at the atmospheric pressure dew point will be 1C or less. Refer to pages 14-19-28 to 29. Construction Refer to pages 14-19-30 to 31.
Elbow/Universal Type Air Flow/Effective Area Model AS121FM-M5 AS131FM-M5 AS221FM-01 AS231FM-01 AS221FM-02 AS231FM-02 RE A B 3.2, 4, 6 3.2, 4 6, 8 4 6 8, 10 Metric size Tubing O.D.
Elbow/Universal Type Air Flow/Effective Area Model AS121FM-M5 AS131FM-M5 AS221FM-01 AS231FM-01 AS221FM-02 AS231FM-02 RE A B 3.2, 4, 6 3.2, 4 6, 8 4 6 8, 10 Metric size Tubing O.D.
Specifications 0.01m (95% filtered particle diameter) Outlet air filtration degree Max. 0.1mg/m (ANR) (0.08ppm) Note 1) Outlet air oil mist concentration (prior to oil saturation 0.01mg/m (ANR) or less (0.008ppm or less) Note 1) With inlet air oil mist concentration of 30mg/m (ANR) (24ppm) Applicable models IDG3V to IDG50V (standard dew point 20C) (4F)) IDG3HV to IDG50HV (standard dew point
For installation indoors, ventilation ports and a ventilation fan should be equipped as needed. 300 mm or more 500 mm or more 100 mm or more Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Power supply 100 V type Power supply 200/230 V type Less than 1000 m 35 40 1.00 Less than 1500 m 34 38 0.85 Less than 2000 m 33 36 0.80 Less than 2500 m 32 34 0.75 Less
Poloneza 89, PL-02-826 Warszawa Portugal SMC Sucursal Portugal, S.A. (351) 22 616 6570 Rua De Eng Ferrerira Dias 452 4100-246,Porto Romania SMC Romania S.r.l. (40)21-3205111 Str.
Note 3) Polyurethane is only applicable for the ZFC050-02. SP ZCUK Made to Order (Refer to page 1115 for details.)
AW-OMX0057-A PRODUCT NAME Filter Regulator MODEL / Series / Product Number AW20(K)-(F,N)01(F,N)02(B,C,E,E1,E2,E3,E4,G,H,M)(-1,2,6,C,J,N,R,Z,ZA)-D AW30(K)-(F,N)02(F,N)03(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AW40(K)-(F,N)02(F,N)04(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AW40(K)-(F,N)06(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AW60(K)-(F,N)06(F,N)10(B,C,
Network length Communication speed [kbps] 9.6 19.2 45.45 93.75 187.5 Max. cable length [m] 1200 1000 Communication speed [kbps] 500 1500 3000 6000 12000 Max. cable length [m] 400 200 100 : Maximum cable length differs depending on the specifications of a cable. The above cable length is based on type A cable.
3/ s 1 x 10 10 Pam3/s 100 kPa 1MPa 100 kPa 1 MPa Rated pressure range 0 0 0 0 100 kPa 100 kPa 2 outputs NPN or PNP Output Switch output Output voltage 1 to 5 V Analog output 16-2-27 4 High Precision, Digital Pressure Switch For General Fluids Series ZSE50F/ISE50 How to Order ISE50 02 22 M L For positive pressure ZSE50 02 M F 22 L For compound pressure Courtesy of Steven Engineering, Inc.-
AR-OMX0055-B PRODUCT NAME Regulator MODEL / Series / Product Number AR20(K)-(F,N)01(F,N)02(B,E,E1,E2,E3,E4,G,H,J,M)(-1,N,R,Y,Z,ZA)-D AR30(K)-(F,N)02(F,N)03(B,E,E1,E2,E3,E4,G,H,J,M)(-1,N,R,Y,Z,ZA)-D AR40(K)-(F,N)02(F,N)04(B,E,E1,E2,E3,E4,G,H,J,M)(-1,N,R,Y,Z,ZA)-D AR40(K)-(F,N)06(B,E,E1,E2,E3,E4,G,H,J,M)(-1,N,R,Y,Z,ZA)-D AR50(K)-(F,N)06(F,N)10(B,E,E1,E2,E3,E4,G,M)(-1,N,R,Y,Z,ZA)-D AR60(K)-(
CE1 CE2 Stroke Stroke Speed ML2B Space-saving has been realized by simple circuit Comparison to Shockless Transfer Systems C J G5-S Time Time Stroke CV P = 0.5 MPa, M = 100 N P = 0.3 MPa, M = 100 N M = 100 N M = 300 N V = 300 mm/s V = 100 mm/s Sine Cylinder Cushioning keep up with depth of orifice as sine function which change depend on stroke.
HRS Series 6.1 Option J [Automatic fluid filling] 6-1 HRX-OM-M090 Chapter 6 OptionOptional Accessories 6.2 Option M [DI water (Pure water) piping] 6.2.1 Option M [DI water (Pure water) piping] This option is for customers who use DI water (pure water) as circulating fluid.
T h e r e i s n o p a r t i c u l a r p r o b l e m i n u s i n g t h e s y s t e m . R e a d t h e i n s t r u c t i o n m a n u a l W i l l y o u d o a t h o r o u g h l y f o r t h i s i t e m a n d c o u n t e r p o s i t i o n i n g m o t i o n ?
AW-OMZ0061 PRODUCT NAME Mist Separator Regulator MODEL / Series / Product Number AWM20-(F,N)01(F,N)02(B,C,E,E1,E2,E3,E4,G,H,M)(-1,2,6,C,J,N,R,Z,ZA)-D AWM30-(F,N)02(F,N)03(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AWM40-(F,N)02(F,N)04(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D Contents Page 1. Safety Instructions 2-8 2. Application 9 3. Standard Specifications 9 4.