Flow Rate and Effective Area Flow direction symbols on body AS2001FM Model AS1001FM AS2051FM 8 3.2, 4, 6 6 6 4 Metric size JIS symbol 1/8", 5/32", 3/16" 1/4" Tube O.D.

Part name Qty (1) Electric Actuator / LEF Series 1 (2) Driver / LECS Series 1 (in case with driver) (3) Motor cable 1 (in case with cable) (4) Encoder cable (5) Lock cable (6) I/O Connector 1 (in case with I/O connector) (2) Driver *2 1 (3) Motor cable (4) Encoder cable (5) Lock cable 24VDC Host controller, (1) Electric Actuator etc (6) I/O connector 2 *1 This picture is LECSA *2 The shape

) (n = 2, 3, 4, 5) D-A9mV 5 10 35 10 + 35(n 2) 2 (n = 2, 4, 6) Note 3) 35 + 25 (n 2) (n = 2, 3, 4, 5) Band mounting D-C7m D-C80 10 15 50 15 + 40(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 20 (n 2) (n = 2, 3, 4, 5) D-H7m/H7mW D-H7BA D-H7NF 10 15 60 15 + 45(n 2) 2 (n = 2, 4, 6) Note 3) 60 + 22.5 (n 2) (n = 2, 3, 4, 5) D-C73C D-C80C D-H7C 10 15 65 15 + 50(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 27.5

3, 4, 5) 20 + 35 D-M9V 5 20 35 CHS (n = 2, 4, 6) Note 3) (n 2) 2 25 + 35 (n 2) (n = 2, 3, 4, 5) 15 + 35 D-A9V 5 15 25 CH2 (n = 2, 4, 6) Note 3) (n 2) 2 D-M9WV D-M9AV 35 + 35 (n 2) (n = 2, 3, 4, 5) 20 + 35 10 20 35 CHA (n = 2, 4, 6) Note 3) (n = 2, 4, 6) Note 3) 15 + 45 (n 2) 2 D-H7/H7W D-H7NF/H7BA 60 + 45 (n 2) (n = 2, 3, 4, 5) 10 15 60 Related Products (n = 2, 4, 6) Note 3) 15 + 45

OUT2 17 OUT output bit Accumulated 1 32 Accumulated 2 33 Flow rate 1 34 Flow rate 2 35 Connected with hardware output SW output bit (Not connected as OUT2 does not have the hardware) Temperature 1 36 Temperature 2 37 Pressure 1 38 Pressure 2 39 Pulse output 2 65 This is valid only when the output object of OUT2 is pulse output.

Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 AL01 : Low level in tank abnormal 1 AL02 : Low level in tank 2 AL03 : Phase loss / phase reverse error 7 3 AL04 : Water leakage 1 4 AL05 : Pump inverter error 2 5 AL06 : Internal fan stop 3 Alarm flag 1 6 AL07 : Fan Inverter error 8 7 Unused 8 AL09

5 4 3 2 1 0 MSB AD LSB Byte2 Byte3 CH1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB AD LSB -31No.EX-OMN0037CN-A -32No.EX-OMN0037CN-A EX600-AM B M12 (5 )4 2 2 M12 (4 ) No. 1 LED 2 () 3 () 4 5 6 () -33No.EX-OMN0037CN-A 1 24 V() 24 V() 2 + 3 0 V() 0 V() 4 0 V() 5 FE FE 1M12 (4 ) 1 1 24 V NC 2 2 A/D DC24 V D/A DC24 V 3 34 0 V 0 V 4 5 FE FE 5 FE FE 100 k 250 1

equipment 7 1 2 Facility water inlet (Water-cooled refrigeration) 8 1 Fluid supply Automatic fluid fill port 2 2 6 Circulating fluid outlet 1 User's equipment 2 2 Circulating fluid return port 3 4 Overflow port To wastewater collection pit Tank drain port 5 * Ensure that the overflow port is connected to the wastewater collection pit in order to avoid damage to the tank of the thermo-chiller

How to change the relationship between transfer direction and piping position 3-6. How to change piping port position 3-7. Shock absorber resistance adjustment method 4. Operation P.12 5. Pneumatic circuit P.12 6. Maintenance P.13 6-1. Check items 6-2. How to replace shock absorber 6-3. Seal replacement 6-3-1. Disassembly & Reassembly 6-3-2. Seal removal 6-3-3. Grease application 6-3-4.

JXC-OMT0054 LEC-OM05805 JXC-OMT0054-A LEC-OM05806 CONTENTS CONTENTS . 1 Introduction . 6 1. Configuration . 7 2. Procedure before operation . 8 2.1 Flow chart . 8 3.

D-C7/C80 50 50 + 45 (n 2) 10 15 15 + 45 ( n 2) (n = 2, 4, 6) 2 D-H7/H7W D-H7NF D60 + 45 (n 2) 60 15 10 D-C73C/C80C D-H7C 15 + 50 ( n 2) (n = 2, 4, 6) -X 2 65 + 50 (n 2) 65 15 10 4. One-touch fitting cannot be replaced. One-touch fitting is press-fit into the cover, thus cannot be replaced.

6!9!2!8 !4w !7 i o A A' Cylinder tube sectional view A-A' !0 !1 Parts list No. q w e r t y u i o !0 !1 !2 !3 No. !4 !5 !6 !7 !8 !

Acceleration [m/s 2] Speed Setting Switch No. Speed [mm/s] 1 1 100 0.49 2 2 200 0.74 3 3 300 0.98 4 4 400 1.23 5 5 500 1.47 6 6 600 1.96 7 7 700 2.45 8 8 800 2.94 9 9 900 3.92 10 10 1000 4.90 Note) The factory default setting for the switch is No.1 (100 mm/s).

2 Chapter 5 Checks, Maintenance and Adjustment . 5-1 5.1 Daily inspection . 5-1 5.2 Regular maintenance . 5-2 5.2.1 Cleaning the ventilation grille . 5-2 5.2.2 Service parts . 5-2 5.2.3 Auto Drain Maintenance . 5-2 5.3 Adjustment . 5-4 5.3.1 Capacity Control Valve . 5-4 IDF190D/240D Series IDX-OM-X011 Contents 5.3.2 Sight glass (for IDF240D only) . 5-4 Chapter 6 Troubleshooting . 6-1 6.1

sides 110 + 30 (n 2) n = 2, 4, 6, 8 35 + 30 (n 2) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com n Same side 110 + 100 (n 2) n = 2, 4, 6, 8 100 + 100 (n 2) 1 110 15 Different sides 110 35 2 Same side 110 55 D-A44 Different sides 110 + 30 (n 2) n = 2, 4, 6,

Solid state switch {3-wi 2 Note) Beler 10 Best Pn6umabcs Vor 1 2 page 1 2-19-1 tor iurther ntormatim m aL(o $tiches 39 91 180 MHcA2-6tr 39 92 183 MHCA2-6! Note l)Ar rhe pss!

About this product Option/Part number Joint screws (2 screws, 2 spacers , 2 nuts) ISA-16Bracket (when control unit not fitted) (Nominal size:3 x 8, 3 screws) ISA-14 Number of stations Part number 2 ISA-16-2 3 ISA-16-3 4 ISA-16-4 5 ISA-16-5 6 ISA-16-6 With connector lead wire ZS-31-B With connector lead wire ZS-31-C : Spacers are included for 4 and 6 stations.

Auto Switch Proper Mounting Position (mm) Auto switch model D-M9 D-M9W D-A9 A A B B Bore size 6 10 16 (4.5) 5.5 (4.5) 5.5 (0.5) 1.5 (0.5) 1.5 (5) 6 (5) 6 (1) 2 (1) 2 (5.5) 6.5 (5.5) 6.5 (1.5) 2.5 (1.5) 2.5 The values in ( ) are measured from the end of the auto switch mounting bracket.