Minimum Stroke for Auto Switch Mounting (mm) D-M9 10 D-M9V 5 D-M9W 15 D-M9WV 10 D-A9 10 D-A9V 5 Number of auto switches mounted Bore size (mm) 32 1, 40 50 2, 63 1 10 5 15 15 10 10 2 1 The outline dimensions for 5 mm stroke will be the same as those for 10 mm stroke. 2 The outline dimensions for 10 mm stroke will be the same as those for 15 mm stroke. 7 Prior to Use Auto Switches Common Specifications
0.5MPa Load factor 50% Piping length 5m Speed controller: AS3000F-06 (S=6.5mm2) Cylinder stroke 100mm Fitting (One-touch fitting) Effective area (mm2)(Cv) Cylinder Speed (mm/s) Model AS3000F-06 (S=6.5mm2) Cylinder stroke 50mm 10 6 16 20 25 32 40 40 50 63 80 100 150 300 450 600 750 150 300 450 600 750 6 4.5 (0.25) VQ1000 (Metal seal) 6 6.3 (0.35) VQ1001 (Rubber seal) Series VQ2000 Cylinder
(packaged together) 50 80 650 F 40 550 G 10 300 H 4 200 J Filter (IN port) Nil Without filter F With filter Note) 100 Note) Flow reduction rate 50 L/min: 5% or less 100 L/min: 5 to 10% 150 L/min: 10 to 15% 80 600 K 40 500 L 10 250 M 4 150 150 Specifications Flow rate (L/min) [at 0.25 MPa] 50 100 150 Power consumption (W) 80 40 10 4 80 40 10 4 80 40 10 4 Type of actuation 2-position 2 port
20 Allowable static moment Ma Nm Allowable static moment Ma Nm Allowable dynamic moment Mea Nm 200.2 8 7 6 5 15 0.0 Collision speed V mm/s 0 100 200 300 400 500 280 560 Data 10 4 8 7 6 5 MXY12 3 2.0 Shock absorber Rubber stopper screw 2 4 Load weight W kg 1.5 Metal stopper screw 3 1.0 1 100 50 200 300 400 560 2 100 50 200 300 400 500 Average speed Va mm/s Collision speed V mm/s 0.5 Average
MGF40 MGF40 20MGF40 MGF40 10 10 10 MGF40 Data MGF40 10 5 4 3 5 4 3 2 2 5 5 1 10 20 30 40 50 100 200 300 400 1 5 4 10 20 30 40 50 100 200 300 400 5 10 50 100 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) l = 200 mm l = 300 mm Graph (3) Graph (4) v = 150 mm/s or less v = 200 mm/s or less Graph (7) Graph (8) 20 300 300 200 200 MGF100 MGF100 20 100 100
Page 603-10 JXC-CD-T JXC-CD-S Straight type JXC-CL-S Straight type T-branch type (Accessory) To SI To ENC To SI To MOT Provided by customer (3 m) Communication cable To PWR Page 603-10 Power supply for controller 24 VDC Power supply plug (Accessory) Page 603-10 Options Teaching box Controller setting kit Conversion cable Note) Page 603-10 P5062-5 (0.3 m) Page 603-10 (With 3 m cable) LEC-T1
Facility water temp. 300 300 35 Heating capacity [W] Heating capacity [W] 35 25 25 5 200 200 5 100 100 0 0 10 15 20 25 30 35 40 10 15 20 25 30 35 40 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9-12 Heating capacity (HRR010-W-20-) 9.5 Heating capacity HRR Series 9-12 HRX-OM-X084 Chapter 9 Documents 9.6 Pump capacity 9.6.1 HRR010-A/W-10/20 0.15 Allowable
Double acting single rod only 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30 12, 16 5, 10, 15, 20, 25, 30 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches Mounting Bracket Part No.
300 300 200 200 Lower limit 100 100 Lower limit 0 0 10 20 30 40 0 10 20 30 40 0 Transfer speed [m/min] Transfer speed [m/min] RS2H63-30 The graphs indicate the values at normal temperature. (20 to 25C) = 0.2 = 0.1 1,000 900 800 700 600 500 400 300 200 100 0 1,000 900 800 700 600 500 400 300 200 100 0 Mass of transferred object m [kg] Mass of transferred object m [kg] 63 Operating range
BDL (108.5) 10 4.6 10 34.3 101 74.5 35 5.5 28.1 12.7 ADDRESS No.
8 16 10 12 12 8 10 10 41 5 8 31 25 to 300 15.5 25 22 17 32 12 10 16 10 12 12 8 10 10 46 6 8 34 25 to 400 19.5 32 24 22 38 16 14 19 11 13 13 8 10 10 53 8 9 40 25 to 500 21 40 24 24 41 18 16 21 12 17 17 11 16 16 54 10 11 48 25 to 500 21 (mm) Bore size (mm) K NN P S T V W ZZ MM NB IA NA -0.020 -0.053 -0.020 -0.053 -0.025 -0.064 -0.025 -0.064 20 5 M22 x 1.5 1/8 81 9.5 4.5 6.5 138 M8 x 1.25 15
For analog voltage output of 0 to 10 V Can be changed Can be changed 10 5 At a time of shipment At a time of shipment Analog output [V] Analog output [V] 1 0 3150 300 0 3150 300 30 3000 30 3000 Maximum value of the display range Maximum value of 10% of the rated flow range 100% of the rated flow range 10% of the rated flow range 100% of the rated flow range the display range Flow [L/min]
) 2) 1) 14 to 194F (10 to 90C) for Vespel and PEEK seat.
: 201 to 300mm 80 40 50 50 20 20 Load weight m (kg) Load weight m (kg) Load weight m (kg) 20 10 10 10 63 63 63 5 5 5 50 50 50 [Example ] 40 40 40 1 1 1 70 100 300 500 1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.
) 24VDC (10%) 24VDC (10%) 100 to 240VAC (10%) 100 to 240VAC (10%) 100 to 240VAC (10%) 24VDC (10%) 100 to 240VAC (10%) Power consumption 20VA or less 10W or less 20VA or less 10W or less 20VA or less 10W or less 10W or less 20VA or less Between case and AC line: 1500VAC for 1 min.
(HRS050-A-20-(BJMTW)) 9.5.2 HRS040-W-20-(BJMTW) 1500 1500 Facility water temperature Facility water temperature 1200 1200 Heating capacity[W] Heating capacity[W] 40 40 900 900 32 32 25 25 600 600 20 20 5 5 300 300 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature[] Circulating fluid temperature[] 60H 50H Fig. 9-6 Heating capacity(HRS050-W-20-(BJMTW)) HRS Series
(Length 300 mm) Without lead wires Without connector Misc.
10 2 10 15 20 CXT 32 40 5 15 10 5 1 10 10 20 (mm) D-F7W D-J79W D-F7BAL D-F7NT D-F79F Auto switch model D-A7 D-A8 D-A73C D-A80C D-A7H D-A80H D-F7 D-J79 D-F7V D-J79C D-F7WV D-F7BAVL D-A79W Application No. of auto switches mounted 2 5 10 15 15 20 20 CXT 32 40 1 5 5 10 15 15 20 Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.