SMC Corporation of America
Elite Part Number Search
Search Results "11-MXJ4-5-M9N"

1.5 4 6 8.5 14.5 11 10.5 16 18 20.5 26.5 9 9.5 13 14 12.5 16 1 0.5 6 8 10.5 16.5 7 6 11.5 13.5 16.5 22.5 11 10.5 16 18 20.5 26.5 5 5.5 9 10 8.5 12 5 (2.5) 9 9.5 13 14 12.5 16 4.5 (2) 10 (7.5) 12 (9.5) 14.5 (12) 20.5 (18) Note 1) ( ): Denotes the values of D-A93.

17 38 39 MXJ 19 10 18 19 18 15 MXP 5 5.5 10 5.5 5.5 MXY NS 4 9 10.5 8.5 31 + Stroke MTS 39.5 + Stroke 16 4 x M3 x 0.5 Depth 4.8 10 5 + Stroke LT NS LB J LA Stroke (mm) 5 14 42 4 10 10 14 10 42 4 15 52 24 20 4 20 52 24 4 20 25 30 62 4 30 30 30 30 62 4 40 20 72 45 20 6 50 82 55 25 6 25 60 60 92 6 30 30 D-X Individual -X 25 Series MXH Dimensions: 10 LT 11 19 11 LA LB J x M4 x 0.7 Depth

Setting Limit Load to the Shaft 10 Use of Shaft Fitting 10 How to Mount Loads 11 Mounting 11 Adjusting the Rotating Angle 12 Operating Environment 13 5. Setting of Rotation Time Moment of Inertia 14 Kinetic Energy 16 Eternal Stopper 17 6. Maintenance and Inspection Standard Type 18 Standard Type 90, 180 Specification 19 Standard Type 270 Specification 20 With Auto Switch 21 7.

L = Stroke 1 2 , or more than 100 mm 1 7 5 4 6 2 6 5 7 3 L L Fig. 11 Position for application of grease Table 10 Amount of grease units: g Stroke 32 40 50 63 80 100 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 50st added 1 1 1 1.5 2 3 26 3-2-4.

11 D-G5/K59/G5W D-K59W/G5BA D-G5NT/G59F D-G39/K39 D-G39C/K39C D-A5/A6 5 6 6.5 6.5 7 D-B5/B64 D-A59W 13 13 14 15 14 9 9 10 10 11 D-B59W 14 14 17 16 18 D-A9 and D-A9V cannot be mounted on 50.

Bore size (mm) Bolt Hexagon wrench size Tightening torque (Nm) 32, 40 MB-32-48-C1247 4 5.1 50, 63 MB-50-48-C1249 5 11 80, 100 Foot MB-80-48AC1251 6 25 Other MB-80-48BC1251 5) When replacing the support brackets, the tie-rod nuts on the cylinder body will be loosened.

, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 18 21.5 46 47 20 23 5 20 6.5 6.5 5 NS 12.5 13 11 7.5 35 + Stroke 46.5 + Stroke 11.5 20 4-M4 x 0.7 Depth 6 5 + Stroke 12 (mm) Stroke (mm) NS LT J LA LB 5 14 10 49 4 10 49 14 10 4 15 59 24 4 20 20 24 59 4 20 25 30 30 69 4 30 69 30 30 4 40 79 45 20 6 20 50 55 89 6 25 25 60 60 30 30

Tighten them with the hexagon socket head cap screw with washers 12 . 17 15 3 10 14 26 11 5 12 19 9 12 14 1 11 26 4 2 6 15 Cushion seal 4 Direction of the shaft(key) 38 - 7. Mount the pipe 21 to the sub-plate 18 19 and 30 and fix with hexagon socket head cap screws 22 31 to the body 1 . 8.

D-A9V D-M9V 5 2 pcs. 10 1 pc. 15 10 5 D-M9 2 pcs. 15 10 1 pc. 15 10 D-M9W 2 pcs. 15 10 1 pc. 10 D-M9WV 2 pcs. 10 1 pc. D-Z7 D-Z80 10 5 2 pcs. 15 10 1 pc. D-Y59 D-Y7P 10 5 2 pcs. 15 10 1 pc. D-Y69 D-Y7PV 5 2 pcs. 5 1 pc.

0 (15) 25 D-M9, D-M9V 15 (17) 0 0 40 50 (57) 32 47 (49) 10 (17) D-F9W, D-F9WV 15 (17) 0 0 40 50 (57) 32 47 (49) 10 (17) D-A9, D-A9V 0 (15) 0 0 50 50 (61) 38 38 (53) 0 (11) 32 D-M9, D-M9V 10 (17) 0 0 50 55 (63) 38 48 (55) 5 (13) D-F9W, D-F9WV 10 (17) 0 0 50 55 (63) 38 48 (55) 5 (13) D-A9, D-A9V 0 (15) 0 0 54 54 (64) 48 48 (63) 0 (10) 40 D-M9, D-M9V 10 (17) 0 0 54 59 (66) 48 58 (65) 5 (12)

-X 0.1 50 100 200 5 20 30 40 10 Overhang L (mm) 233 Series MTS Horizontal Mounting 8 Maximum speed: Up to 500 mm/s Maximum speed: Up to 300 mm/s Graph (8) Stroke: Up to 10 stroke Graph (11) Stroke: Up to 10 stroke 0.1 0.1 0.05 0.05 Mass W (kg) Mass W (kg) 0.04 0.04 0.03 0.03 8 0.02 0.02 8 0.01 0.01 0 10 15 25 20 30 5 5 0 10 15 20 25 30 Overhang L (mm) Overhang L (mm) Graph (9) Stroke: Up

I-P006A I-P010A I-P016A Y-P006A Y-P010A Y-P016A 5 +0.040 0 0.020 0.045 +0.040 0 3 3 3 6 9 12 3.5 M3 x 0.5 3 5 4 5 6 5 6 12 3.5 M3 x 0.5 3 5 4 5 6 6.5 +0.048 0 0.030 0.060 +0.048 0 5 5 5 10 13.6 16 5.5 M4 x 0.7 5 8 6.3 7 10 6.5 10 16 5.5 M4 x 0.7 5 8 6.3 7 10 7 +0.048 0 0.030 0.060 +0.048 0 6 6 6 12 15.8 19 7 M5 x 0.8 6 10 7.8 9 16 7 12 19 7 M5 x 0.8 6 10 7.8 9 16 Knuckle pin Trunnion pin

D-M9WV D-M9AV 5 Note 2) 1 pc. 10 2 pcs. 5 Note 2) 1 pc. D-M9A 10 Note 2) 2 pcs. 5 1 pc. D-M9V 5 2 pcs. 5 1 pc. D-A9V 10 2 pcs. 5 1 pc. D-A9 10 2 pcs. 1 pc. 15 D-P3DWA 2 pcs. 15 Note 1) Confirm that it is possible to secure the minimum bending radius of 10 mm of the auto switch lead wire before use.

Operating Range (mm) Auto switch model Bore size 12 16 20 25 32 40 50 63 D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-A9/A9V 6.5 5 5 5 5.5 5 4 3 11 9.5 9.5 9 9 10 7.5 6 D-F7/J79 D-F7V/J79C D-F7W/F7WV D-J79W D-F79F/F7BA D-F7BAV/F7NT 7.5 6.5 6.5 6 6 6 Since this is a guideline including hysteresis, not meant to be guaranteed (assuming approximately 30% dispersion).

Mounting, Operation P.10 1) Operating air P.10 2) Precaution on design P.11 3) Mounting P.13 4) Operating environment P.13 5) Piping P.14 6) Cushion P.15 7) Speed control P.16 8) Direction control P.16 4. Maintenance P.17 1) Inspection P.17 2) Overhaul P.18 3) Disassembly P.18 4) Assembly P.19 5) Expendable supplies P.20 6) Replacement procedure of seal P.21 7) Inspection P.22 5.

Noise countermeasures 8 Chapter 5: Structure and Measuring Principle 5-1. Structure 9 5-2. Measuring Principle 10 5-3. Relationship Between Pulse and Count10 Chapter 6: Troubleshooting 6-1. Troubleshooting for Measuring Function11 6-2.

D-M9B D-M9N, D-M9P D-A93 Load voltage Load current range Indicator light Application 24 VDC (10 to 28 VDC) 28 VDC or less 24 VDC, 100 VAC 2.5 to 40 mA 40 mA or less 5 to 40 mA, 5 to 20 mA 24 VDC relay, PLC IC circuit, Relay, PLC Relay, PLC Solid state auto switch PLC: Programmable Logic Controller Refer to page 920 for the applicable auto switch list. 905 Rotary Actuator 11-CRA1-Z Rotation